§63.508. Flare requirements. — Inbound Citations
40 C.F.R. § 63.508
Statutory Authority
Cited by 52 regulations in release Current.
Citations to 40 C.F.R. § 63.508 as a whole
-
(2) Owners and operators of flares that are subject to the flare related requirements of this subpart and are also subject to flare related requirements of any other regulation in this part or 40 CFR part 61 or 63, may elect to comply with the requirements in § 63.508 in lieu of all flare related requirements in any other regulation in this part or 40 CFR part 61 or 63.
-
-
(3) For each affected source as described in § 63.480, beginning no later than the compliance dates specified in § 63.481(n), paragraphs (q)(1)(ii) and (q)(2) of this section no longer apply. Instead, the requirements of § 63.113(a)(2); §§ 63.113(b) and the associated testing requirements in § 63.116; or § 63.508 must be met.
-
(iii) For each affected source as described in § 63.480, beginning no later than the compliance dates specified in § 63.481(n), paragraph (a)(1)(i) of this section no longer applies and instead the owner or operator of the affected sources must comply with § 63.508 for the flare.
-
(9) For each affected source as described in § 63.480, beginning no later than the compliance dates specified in § 63.481(n), paragraph (b)(2) of this section no longer applies and instead the owner or operator of the affected source must comply with § 63.508 for the flare.
-
(2) For each affected source as described in § 63.480, beginning no later than the compliance dates specified in § 63.481(n), paragraph (a)(1) of this section no longer applies and instead the owner or operator of the affected source must comply with § 63.508 for the flare.
-
(iv) For each affected source as described in § 63.480, beginning no later than the compliance dates specified in § 63.481(n), paragraphs (b)(3)(i) through (b)(3)(iii) of this section no longer apply and instead the owner or operator of the affected source must keep the records specified in § 63.108(m) of subpart F of this part and § 63.508, readily accessible when using a flare to comply with § 63.487(a)(1).
-
(e) For each affected source as described in § 63.480, beginning no later than the compliance dates specified in § 63.481(n), paragraph (d) of this section no longer applies and instead if the owner or operator complies with the residual organic HAP limitations in paragraph (a)(1) through (3) of this section using a flare, the owner or operator of the affected source must comply with § 63.508 for the flare.
-
(B) For each affected source as described in § 63.480, beginning no later than the compliance dates specified in § 63.481(n), paragraph (b)(7)(i)(A) of this section no longer applies and instead the owner or operator of the affected source must comply with § 63.508 for the flare.
-
(7) For each affected source as described in § 63.480, beginning no later than the compliance dates specified in § 63.481(n), paragraph (a)(2) of this section no longer applies and instead the owner or operator of the affected source must comply with § 63.508 for the flare.
-
(i) Continuous records of the equipment operating parameters specified to be monitored under § 63.497(a) or specified by the Administrator in accordance with § 63.497(b). For flares, the records specified in § 63.508, if applicable, and table 3 to subpart G of this part shall be maintained in place of continuous records.
-
-
-
(4) For each affected source as described in § 63.480, beginning no later than the compliance dates specified in § 63.481(n), paragraphs (c)(1) through (c)(3) of this section no longer apply and instead the owner or operator of the affected source must comply with § 63.508 for the flare.
-
(xiii) For flares subject to the requirements in § 63.508, owners and operators must also submit the information in this paragraph in a supplement to the Notification of Compliance Status within 150 days after the first applicable compliance date for flare monitoring. The supplement to the Notification of Compliance Status must include flare design (e.g., steam-assisted, air-assisted, or non-assisted); all visible emission readings, heat content determinations, flow rate measurements, and exit velocity determinations made during the initial visible emissions demonstration required by § 63.670(h), as applicable; and all periods during the compliance determination when the pilot flame or flare flame is absent.
Citations to §63.508(a)(1)
-
(a) For any flare that is used to reduce organic HAP emissions from an EPPU, the owner or operator may elect to comply with the requirements in this section in lieu of the requirements of § 63.11(b) and the requirements referenced therein. The owner or operator may also elect to comply with the requirements in this section pursuant to the overlap provisions provided in § 63.481(k)(2). However, beginning no later than the compliance dates specified in § 63.481(n), the provisions specified in paragraphs (a)(1) through (32) of this section no longer apply. Instead, if an owner or operator reduces organic HAP emissions from an EPPU by venting emissions through a closed-vent system to a steam-assisted, air-assisted, or non-assisted flare, then the owner or operator must meet the applicable requirements for flares as specified in §§ 63.670 and 63.671, including the provisions in tables 12 and 13 to subpart CC of this part, except as specified in paragraph (b) of this section. This requirement also applies to any flare using fuel gas from a fuel gas system, of which 50 percent or more of the fuel gas is derived from a EPPU, as determined on an annual average basis. For purposes of compliance with this paragraph, the following terms are defined in § 63.641 of subpart CC of this part: Assist air, assist steam, center steam, combustion zone, combustion zone gas, flare, flare purge gas, flare supplemental gas, flare sweep gas, flare vent gas, lower steam, net heating value, perimeter assist air, pilot gas, premix assist air, total steam, and upper steam.(1) §§ 63.487(a)(1)(i) and (b)(1)(i);(2) § 63.489(b)(2);(3) § 63.490(a)(1);(5) § 63.494(d);(6) § 63.496(b)(7)(i)(A);(7) § 63.497(a)(2);(9) § 63.502(k)(1);(11) § 63.107(h)(9)(i) related to criteria in § 63.11(b);(12) § 63.113(a)(1);(13) § 63.114(a)(2);(16) § 63.118(f)(5);(17) The last sentence in § 63.119(e)(1);(19) §§ 63.122(c)(2) and (g)(3);(20) § 63.126(b)(2)(i);(21) § 63.127(a)(2);(24) §§ 63.130(a)(2)(i), (c), and (d)(5);(25) §§ 63.139(c)(3) and (d)(3);(28) § 63.147(d)(1);(29) §§ 63.172(d);(31) § 63.181(g)(1)(iii); and(32) The phrase “including periods when a flare pilot light system does not have a flame” in § 63.181(g)(2)(i).
Citations to §63.508(a)(2)
-
(a) For any flare that is used to reduce organic HAP emissions from an EPPU, the owner or operator may elect to comply with the requirements in this section in lieu of the requirements of § 63.11(b) and the requirements referenced therein. The owner or operator may also elect to comply with the requirements in this section pursuant to the overlap provisions provided in § 63.481(k)(2). However, beginning no later than the compliance dates specified in § 63.481(n), the provisions specified in paragraphs (a)(1) through (32) of this section no longer apply. Instead, if an owner or operator reduces organic HAP emissions from an EPPU by venting emissions through a closed-vent system to a steam-assisted, air-assisted, or non-assisted flare, then the owner or operator must meet the applicable requirements for flares as specified in §§ 63.670 and 63.671, including the provisions in tables 12 and 13 to subpart CC of this part, except as specified in paragraph (b) of this section. This requirement also applies to any flare using fuel gas from a fuel gas system, of which 50 percent or more of the fuel gas is derived from a EPPU, as determined on an annual average basis. For purposes of compliance with this paragraph, the following terms are defined in § 63.641 of subpart CC of this part: Assist air, assist steam, center steam, combustion zone, combustion zone gas, flare, flare purge gas, flare supplemental gas, flare sweep gas, flare vent gas, lower steam, net heating value, perimeter assist air, pilot gas, premix assist air, total steam, and upper steam.(1) §§ 63.487(a)(1)(i) and (b)(1)(i);(2) § 63.489(b)(2);(3) § 63.490(a)(1);(5) § 63.494(d);(6) § 63.496(b)(7)(i)(A);(7) § 63.497(a)(2);(9) § 63.502(k)(1);(11) § 63.107(h)(9)(i) related to criteria in § 63.11(b);(12) § 63.113(a)(1);(13) § 63.114(a)(2);(16) § 63.118(f)(5);(17) The last sentence in § 63.119(e)(1);(19) §§ 63.122(c)(2) and (g)(3);(20) § 63.126(b)(2)(i);(21) § 63.127(a)(2);(24) §§ 63.130(a)(2)(i), (c), and (d)(5);(25) §§ 63.139(c)(3) and (d)(3);(28) § 63.147(d)(1);(29) §§ 63.172(d);(31) § 63.181(g)(1)(iii); and(32) The phrase “including periods when a flare pilot light system does not have a flame” in § 63.181(g)(2)(i).
Citations to §63.508(a)(3)
-
(a) For any flare that is used to reduce organic HAP emissions from an EPPU, the owner or operator may elect to comply with the requirements in this section in lieu of the requirements of § 63.11(b) and the requirements referenced therein. The owner or operator may also elect to comply with the requirements in this section pursuant to the overlap provisions provided in § 63.481(k)(2). However, beginning no later than the compliance dates specified in § 63.481(n), the provisions specified in paragraphs (a)(1) through (32) of this section no longer apply. Instead, if an owner or operator reduces organic HAP emissions from an EPPU by venting emissions through a closed-vent system to a steam-assisted, air-assisted, or non-assisted flare, then the owner or operator must meet the applicable requirements for flares as specified in §§ 63.670 and 63.671, including the provisions in tables 12 and 13 to subpart CC of this part, except as specified in paragraph (b) of this section. This requirement also applies to any flare using fuel gas from a fuel gas system, of which 50 percent or more of the fuel gas is derived from a EPPU, as determined on an annual average basis. For purposes of compliance with this paragraph, the following terms are defined in § 63.641 of subpart CC of this part: Assist air, assist steam, center steam, combustion zone, combustion zone gas, flare, flare purge gas, flare supplemental gas, flare sweep gas, flare vent gas, lower steam, net heating value, perimeter assist air, pilot gas, premix assist air, total steam, and upper steam.(1) §§ 63.487(a)(1)(i) and (b)(1)(i);(2) § 63.489(b)(2);(3) § 63.490(a)(1);(5) § 63.494(d);(6) § 63.496(b)(7)(i)(A);(7) § 63.497(a)(2);(9) § 63.502(k)(1);(11) § 63.107(h)(9)(i) related to criteria in § 63.11(b);(12) § 63.113(a)(1);(13) § 63.114(a)(2);(16) § 63.118(f)(5);(17) The last sentence in § 63.119(e)(1);(19) §§ 63.122(c)(2) and (g)(3);(20) § 63.126(b)(2)(i);(21) § 63.127(a)(2);(24) §§ 63.130(a)(2)(i), (c), and (d)(5);(25) §§ 63.139(c)(3) and (d)(3);(28) § 63.147(d)(1);(29) §§ 63.172(d);(31) § 63.181(g)(1)(iii); and(32) The phrase “including periods when a flare pilot light system does not have a flame” in § 63.181(g)(2)(i).
Citations to §63.508(a)(4)
-
(a) For any flare that is used to reduce organic HAP emissions from an EPPU, the owner or operator may elect to comply with the requirements in this section in lieu of the requirements of § 63.11(b) and the requirements referenced therein. The owner or operator may also elect to comply with the requirements in this section pursuant to the overlap provisions provided in § 63.481(k)(2). However, beginning no later than the compliance dates specified in § 63.481(n), the provisions specified in paragraphs (a)(1) through (32) of this section no longer apply. Instead, if an owner or operator reduces organic HAP emissions from an EPPU by venting emissions through a closed-vent system to a steam-assisted, air-assisted, or non-assisted flare, then the owner or operator must meet the applicable requirements for flares as specified in §§ 63.670 and 63.671, including the provisions in tables 12 and 13 to subpart CC of this part, except as specified in paragraph (b) of this section. This requirement also applies to any flare using fuel gas from a fuel gas system, of which 50 percent or more of the fuel gas is derived from a EPPU, as determined on an annual average basis. For purposes of compliance with this paragraph, the following terms are defined in § 63.641 of subpart CC of this part: Assist air, assist steam, center steam, combustion zone, combustion zone gas, flare, flare purge gas, flare supplemental gas, flare sweep gas, flare vent gas, lower steam, net heating value, perimeter assist air, pilot gas, premix assist air, total steam, and upper steam.(1) §§ 63.487(a)(1)(i) and (b)(1)(i);(2) § 63.489(b)(2);(3) § 63.490(a)(1);(5) § 63.494(d);(6) § 63.496(b)(7)(i)(A);(7) § 63.497(a)(2);(9) § 63.502(k)(1);(11) § 63.107(h)(9)(i) related to criteria in § 63.11(b);(12) § 63.113(a)(1);(13) § 63.114(a)(2);(16) § 63.118(f)(5);(17) The last sentence in § 63.119(e)(1);(19) §§ 63.122(c)(2) and (g)(3);(20) § 63.126(b)(2)(i);(21) § 63.127(a)(2);(24) §§ 63.130(a)(2)(i), (c), and (d)(5);(25) §§ 63.139(c)(3) and (d)(3);(28) § 63.147(d)(1);(29) §§ 63.172(d);(31) § 63.181(g)(1)(iii); and(32) The phrase “including periods when a flare pilot light system does not have a flame” in § 63.181(g)(2)(i).
Citations to §63.508(a)(5)
-
(a) For any flare that is used to reduce organic HAP emissions from an EPPU, the owner or operator may elect to comply with the requirements in this section in lieu of the requirements of § 63.11(b) and the requirements referenced therein. The owner or operator may also elect to comply with the requirements in this section pursuant to the overlap provisions provided in § 63.481(k)(2). However, beginning no later than the compliance dates specified in § 63.481(n), the provisions specified in paragraphs (a)(1) through (32) of this section no longer apply. Instead, if an owner or operator reduces organic HAP emissions from an EPPU by venting emissions through a closed-vent system to a steam-assisted, air-assisted, or non-assisted flare, then the owner or operator must meet the applicable requirements for flares as specified in §§ 63.670 and 63.671, including the provisions in tables 12 and 13 to subpart CC of this part, except as specified in paragraph (b) of this section. This requirement also applies to any flare using fuel gas from a fuel gas system, of which 50 percent or more of the fuel gas is derived from a EPPU, as determined on an annual average basis. For purposes of compliance with this paragraph, the following terms are defined in § 63.641 of subpart CC of this part: Assist air, assist steam, center steam, combustion zone, combustion zone gas, flare, flare purge gas, flare supplemental gas, flare sweep gas, flare vent gas, lower steam, net heating value, perimeter assist air, pilot gas, premix assist air, total steam, and upper steam.(1) §§ 63.487(a)(1)(i) and (b)(1)(i);(2) § 63.489(b)(2);(3) § 63.490(a)(1);(5) § 63.494(d);(6) § 63.496(b)(7)(i)(A);(7) § 63.497(a)(2);(9) § 63.502(k)(1);(11) § 63.107(h)(9)(i) related to criteria in § 63.11(b);(12) § 63.113(a)(1);(13) § 63.114(a)(2);(16) § 63.118(f)(5);(17) The last sentence in § 63.119(e)(1);(19) §§ 63.122(c)(2) and (g)(3);(20) § 63.126(b)(2)(i);(21) § 63.127(a)(2);(24) §§ 63.130(a)(2)(i), (c), and (d)(5);(25) §§ 63.139(c)(3) and (d)(3);(28) § 63.147(d)(1);(29) §§ 63.172(d);(31) § 63.181(g)(1)(iii); and(32) The phrase “including periods when a flare pilot light system does not have a flame” in § 63.181(g)(2)(i).
Citations to §63.508(a)(6)
-
(a) For any flare that is used to reduce organic HAP emissions from an EPPU, the owner or operator may elect to comply with the requirements in this section in lieu of the requirements of § 63.11(b) and the requirements referenced therein. The owner or operator may also elect to comply with the requirements in this section pursuant to the overlap provisions provided in § 63.481(k)(2). However, beginning no later than the compliance dates specified in § 63.481(n), the provisions specified in paragraphs (a)(1) through (32) of this section no longer apply. Instead, if an owner or operator reduces organic HAP emissions from an EPPU by venting emissions through a closed-vent system to a steam-assisted, air-assisted, or non-assisted flare, then the owner or operator must meet the applicable requirements for flares as specified in §§ 63.670 and 63.671, including the provisions in tables 12 and 13 to subpart CC of this part, except as specified in paragraph (b) of this section. This requirement also applies to any flare using fuel gas from a fuel gas system, of which 50 percent or more of the fuel gas is derived from a EPPU, as determined on an annual average basis. For purposes of compliance with this paragraph, the following terms are defined in § 63.641 of subpart CC of this part: Assist air, assist steam, center steam, combustion zone, combustion zone gas, flare, flare purge gas, flare supplemental gas, flare sweep gas, flare vent gas, lower steam, net heating value, perimeter assist air, pilot gas, premix assist air, total steam, and upper steam.(1) §§ 63.487(a)(1)(i) and (b)(1)(i);(2) § 63.489(b)(2);(3) § 63.490(a)(1);(5) § 63.494(d);(6) § 63.496(b)(7)(i)(A);(7) § 63.497(a)(2);(9) § 63.502(k)(1);(11) § 63.107(h)(9)(i) related to criteria in § 63.11(b);(12) § 63.113(a)(1);(13) § 63.114(a)(2);(16) § 63.118(f)(5);(17) The last sentence in § 63.119(e)(1);(19) §§ 63.122(c)(2) and (g)(3);(20) § 63.126(b)(2)(i);(21) § 63.127(a)(2);(24) §§ 63.130(a)(2)(i), (c), and (d)(5);(25) §§ 63.139(c)(3) and (d)(3);(28) § 63.147(d)(1);(29) §§ 63.172(d);(31) § 63.181(g)(1)(iii); and(32) The phrase “including periods when a flare pilot light system does not have a flame” in § 63.181(g)(2)(i).
Citations to §63.508(a)(7)
-
(a) For any flare that is used to reduce organic HAP emissions from an EPPU, the owner or operator may elect to comply with the requirements in this section in lieu of the requirements of § 63.11(b) and the requirements referenced therein. The owner or operator may also elect to comply with the requirements in this section pursuant to the overlap provisions provided in § 63.481(k)(2). However, beginning no later than the compliance dates specified in § 63.481(n), the provisions specified in paragraphs (a)(1) through (32) of this section no longer apply. Instead, if an owner or operator reduces organic HAP emissions from an EPPU by venting emissions through a closed-vent system to a steam-assisted, air-assisted, or non-assisted flare, then the owner or operator must meet the applicable requirements for flares as specified in §§ 63.670 and 63.671, including the provisions in tables 12 and 13 to subpart CC of this part, except as specified in paragraph (b) of this section. This requirement also applies to any flare using fuel gas from a fuel gas system, of which 50 percent or more of the fuel gas is derived from a EPPU, as determined on an annual average basis. For purposes of compliance with this paragraph, the following terms are defined in § 63.641 of subpart CC of this part: Assist air, assist steam, center steam, combustion zone, combustion zone gas, flare, flare purge gas, flare supplemental gas, flare sweep gas, flare vent gas, lower steam, net heating value, perimeter assist air, pilot gas, premix assist air, total steam, and upper steam.(1) §§ 63.487(a)(1)(i) and (b)(1)(i);(2) § 63.489(b)(2);(3) § 63.490(a)(1);(5) § 63.494(d);(6) § 63.496(b)(7)(i)(A);(7) § 63.497(a)(2);(9) § 63.502(k)(1);(11) § 63.107(h)(9)(i) related to criteria in § 63.11(b);(12) § 63.113(a)(1);(13) § 63.114(a)(2);(16) § 63.118(f)(5);(17) The last sentence in § 63.119(e)(1);(19) §§ 63.122(c)(2) and (g)(3);(20) § 63.126(b)(2)(i);(21) § 63.127(a)(2);(24) §§ 63.130(a)(2)(i), (c), and (d)(5);(25) §§ 63.139(c)(3) and (d)(3);(28) § 63.147(d)(1);(29) §§ 63.172(d);(31) § 63.181(g)(1)(iii); and(32) The phrase “including periods when a flare pilot light system does not have a flame” in § 63.181(g)(2)(i).
Citations to §63.508(a)(8)
-
(a) For any flare that is used to reduce organic HAP emissions from an EPPU, the owner or operator may elect to comply with the requirements in this section in lieu of the requirements of § 63.11(b) and the requirements referenced therein. The owner or operator may also elect to comply with the requirements in this section pursuant to the overlap provisions provided in § 63.481(k)(2). However, beginning no later than the compliance dates specified in § 63.481(n), the provisions specified in paragraphs (a)(1) through (32) of this section no longer apply. Instead, if an owner or operator reduces organic HAP emissions from an EPPU by venting emissions through a closed-vent system to a steam-assisted, air-assisted, or non-assisted flare, then the owner or operator must meet the applicable requirements for flares as specified in §§ 63.670 and 63.671, including the provisions in tables 12 and 13 to subpart CC of this part, except as specified in paragraph (b) of this section. This requirement also applies to any flare using fuel gas from a fuel gas system, of which 50 percent or more of the fuel gas is derived from a EPPU, as determined on an annual average basis. For purposes of compliance with this paragraph, the following terms are defined in § 63.641 of subpart CC of this part: Assist air, assist steam, center steam, combustion zone, combustion zone gas, flare, flare purge gas, flare supplemental gas, flare sweep gas, flare vent gas, lower steam, net heating value, perimeter assist air, pilot gas, premix assist air, total steam, and upper steam.(1) §§ 63.487(a)(1)(i) and (b)(1)(i);(2) § 63.489(b)(2);(3) § 63.490(a)(1);(5) § 63.494(d);(6) § 63.496(b)(7)(i)(A);(7) § 63.497(a)(2);(9) § 63.502(k)(1);(11) § 63.107(h)(9)(i) related to criteria in § 63.11(b);(12) § 63.113(a)(1);(13) § 63.114(a)(2);(16) § 63.118(f)(5);(17) The last sentence in § 63.119(e)(1);(19) §§ 63.122(c)(2) and (g)(3);(20) § 63.126(b)(2)(i);(21) § 63.127(a)(2);(24) §§ 63.130(a)(2)(i), (c), and (d)(5);(25) §§ 63.139(c)(3) and (d)(3);(28) § 63.147(d)(1);(29) §§ 63.172(d);(31) § 63.181(g)(1)(iii); and(32) The phrase “including periods when a flare pilot light system does not have a flame” in § 63.181(g)(2)(i).
Citations to §63.508(a)(9)
-
(a) For any flare that is used to reduce organic HAP emissions from an EPPU, the owner or operator may elect to comply with the requirements in this section in lieu of the requirements of § 63.11(b) and the requirements referenced therein. The owner or operator may also elect to comply with the requirements in this section pursuant to the overlap provisions provided in § 63.481(k)(2). However, beginning no later than the compliance dates specified in § 63.481(n), the provisions specified in paragraphs (a)(1) through (32) of this section no longer apply. Instead, if an owner or operator reduces organic HAP emissions from an EPPU by venting emissions through a closed-vent system to a steam-assisted, air-assisted, or non-assisted flare, then the owner or operator must meet the applicable requirements for flares as specified in §§ 63.670 and 63.671, including the provisions in tables 12 and 13 to subpart CC of this part, except as specified in paragraph (b) of this section. This requirement also applies to any flare using fuel gas from a fuel gas system, of which 50 percent or more of the fuel gas is derived from a EPPU, as determined on an annual average basis. For purposes of compliance with this paragraph, the following terms are defined in § 63.641 of subpart CC of this part: Assist air, assist steam, center steam, combustion zone, combustion zone gas, flare, flare purge gas, flare supplemental gas, flare sweep gas, flare vent gas, lower steam, net heating value, perimeter assist air, pilot gas, premix assist air, total steam, and upper steam.(1) §§ 63.487(a)(1)(i) and (b)(1)(i);(2) § 63.489(b)(2);(3) § 63.490(a)(1);(5) § 63.494(d);(6) § 63.496(b)(7)(i)(A);(7) § 63.497(a)(2);(9) § 63.502(k)(1);(11) § 63.107(h)(9)(i) related to criteria in § 63.11(b);(12) § 63.113(a)(1);(13) § 63.114(a)(2);(16) § 63.118(f)(5);(17) The last sentence in § 63.119(e)(1);(19) §§ 63.122(c)(2) and (g)(3);(20) § 63.126(b)(2)(i);(21) § 63.127(a)(2);(24) §§ 63.130(a)(2)(i), (c), and (d)(5);(25) §§ 63.139(c)(3) and (d)(3);(28) § 63.147(d)(1);(29) §§ 63.172(d);(31) § 63.181(g)(1)(iii); and(32) The phrase “including periods when a flare pilot light system does not have a flame” in § 63.181(g)(2)(i).
Citations to §63.508(a)(10)
-
(a) For any flare that is used to reduce organic HAP emissions from an EPPU, the owner or operator may elect to comply with the requirements in this section in lieu of the requirements of § 63.11(b) and the requirements referenced therein. The owner or operator may also elect to comply with the requirements in this section pursuant to the overlap provisions provided in § 63.481(k)(2). However, beginning no later than the compliance dates specified in § 63.481(n), the provisions specified in paragraphs (a)(1) through (32) of this section no longer apply. Instead, if an owner or operator reduces organic HAP emissions from an EPPU by venting emissions through a closed-vent system to a steam-assisted, air-assisted, or non-assisted flare, then the owner or operator must meet the applicable requirements for flares as specified in §§ 63.670 and 63.671, including the provisions in tables 12 and 13 to subpart CC of this part, except as specified in paragraph (b) of this section. This requirement also applies to any flare using fuel gas from a fuel gas system, of which 50 percent or more of the fuel gas is derived from a EPPU, as determined on an annual average basis. For purposes of compliance with this paragraph, the following terms are defined in § 63.641 of subpart CC of this part: Assist air, assist steam, center steam, combustion zone, combustion zone gas, flare, flare purge gas, flare supplemental gas, flare sweep gas, flare vent gas, lower steam, net heating value, perimeter assist air, pilot gas, premix assist air, total steam, and upper steam.(1) §§ 63.487(a)(1)(i) and (b)(1)(i);(2) § 63.489(b)(2);(3) § 63.490(a)(1);(5) § 63.494(d);(6) § 63.496(b)(7)(i)(A);(7) § 63.497(a)(2);(9) § 63.502(k)(1);(11) § 63.107(h)(9)(i) related to criteria in § 63.11(b);(12) § 63.113(a)(1);(13) § 63.114(a)(2);(16) § 63.118(f)(5);(17) The last sentence in § 63.119(e)(1);(19) §§ 63.122(c)(2) and (g)(3);(20) § 63.126(b)(2)(i);(21) § 63.127(a)(2);(24) §§ 63.130(a)(2)(i), (c), and (d)(5);(25) §§ 63.139(c)(3) and (d)(3);(28) § 63.147(d)(1);(29) §§ 63.172(d);(31) § 63.181(g)(1)(iii); and(32) The phrase “including periods when a flare pilot light system does not have a flame” in § 63.181(g)(2)(i).
Citations to §63.508(a)(11)
-
(a) For any flare that is used to reduce organic HAP emissions from an EPPU, the owner or operator may elect to comply with the requirements in this section in lieu of the requirements of § 63.11(b) and the requirements referenced therein. The owner or operator may also elect to comply with the requirements in this section pursuant to the overlap provisions provided in § 63.481(k)(2). However, beginning no later than the compliance dates specified in § 63.481(n), the provisions specified in paragraphs (a)(1) through (32) of this section no longer apply. Instead, if an owner or operator reduces organic HAP emissions from an EPPU by venting emissions through a closed-vent system to a steam-assisted, air-assisted, or non-assisted flare, then the owner or operator must meet the applicable requirements for flares as specified in §§ 63.670 and 63.671, including the provisions in tables 12 and 13 to subpart CC of this part, except as specified in paragraph (b) of this section. This requirement also applies to any flare using fuel gas from a fuel gas system, of which 50 percent or more of the fuel gas is derived from a EPPU, as determined on an annual average basis. For purposes of compliance with this paragraph, the following terms are defined in § 63.641 of subpart CC of this part: Assist air, assist steam, center steam, combustion zone, combustion zone gas, flare, flare purge gas, flare supplemental gas, flare sweep gas, flare vent gas, lower steam, net heating value, perimeter assist air, pilot gas, premix assist air, total steam, and upper steam.(1) §§ 63.487(a)(1)(i) and (b)(1)(i);(2) § 63.489(b)(2);(3) § 63.490(a)(1);(5) § 63.494(d);(6) § 63.496(b)(7)(i)(A);(7) § 63.497(a)(2);(9) § 63.502(k)(1);(11) § 63.107(h)(9)(i) related to criteria in § 63.11(b);(12) § 63.113(a)(1);(13) § 63.114(a)(2);(16) § 63.118(f)(5);(17) The last sentence in § 63.119(e)(1);(19) §§ 63.122(c)(2) and (g)(3);(20) § 63.126(b)(2)(i);(21) § 63.127(a)(2);(24) §§ 63.130(a)(2)(i), (c), and (d)(5);(25) §§ 63.139(c)(3) and (d)(3);(28) § 63.147(d)(1);(29) §§ 63.172(d);(31) § 63.181(g)(1)(iii); and(32) The phrase “including periods when a flare pilot light system does not have a flame” in § 63.181(g)(2)(i).
Citations to §63.508(a)(12)
-
(a) For any flare that is used to reduce organic HAP emissions from an EPPU, the owner or operator may elect to comply with the requirements in this section in lieu of the requirements of § 63.11(b) and the requirements referenced therein. The owner or operator may also elect to comply with the requirements in this section pursuant to the overlap provisions provided in § 63.481(k)(2). However, beginning no later than the compliance dates specified in § 63.481(n), the provisions specified in paragraphs (a)(1) through (32) of this section no longer apply. Instead, if an owner or operator reduces organic HAP emissions from an EPPU by venting emissions through a closed-vent system to a steam-assisted, air-assisted, or non-assisted flare, then the owner or operator must meet the applicable requirements for flares as specified in §§ 63.670 and 63.671, including the provisions in tables 12 and 13 to subpart CC of this part, except as specified in paragraph (b) of this section. This requirement also applies to any flare using fuel gas from a fuel gas system, of which 50 percent or more of the fuel gas is derived from a EPPU, as determined on an annual average basis. For purposes of compliance with this paragraph, the following terms are defined in § 63.641 of subpart CC of this part: Assist air, assist steam, center steam, combustion zone, combustion zone gas, flare, flare purge gas, flare supplemental gas, flare sweep gas, flare vent gas, lower steam, net heating value, perimeter assist air, pilot gas, premix assist air, total steam, and upper steam.(1) §§ 63.487(a)(1)(i) and (b)(1)(i);(2) § 63.489(b)(2);(3) § 63.490(a)(1);(5) § 63.494(d);(6) § 63.496(b)(7)(i)(A);(7) § 63.497(a)(2);(9) § 63.502(k)(1);(11) § 63.107(h)(9)(i) related to criteria in § 63.11(b);(12) § 63.113(a)(1);(13) § 63.114(a)(2);(16) § 63.118(f)(5);(17) The last sentence in § 63.119(e)(1);(19) §§ 63.122(c)(2) and (g)(3);(20) § 63.126(b)(2)(i);(21) § 63.127(a)(2);(24) §§ 63.130(a)(2)(i), (c), and (d)(5);(25) §§ 63.139(c)(3) and (d)(3);(28) § 63.147(d)(1);(29) §§ 63.172(d);(31) § 63.181(g)(1)(iii); and(32) The phrase “including periods when a flare pilot light system does not have a flame” in § 63.181(g)(2)(i).
Citations to §63.508(a)(13)
-
(a) For any flare that is used to reduce organic HAP emissions from an EPPU, the owner or operator may elect to comply with the requirements in this section in lieu of the requirements of § 63.11(b) and the requirements referenced therein. The owner or operator may also elect to comply with the requirements in this section pursuant to the overlap provisions provided in § 63.481(k)(2). However, beginning no later than the compliance dates specified in § 63.481(n), the provisions specified in paragraphs (a)(1) through (32) of this section no longer apply. Instead, if an owner or operator reduces organic HAP emissions from an EPPU by venting emissions through a closed-vent system to a steam-assisted, air-assisted, or non-assisted flare, then the owner or operator must meet the applicable requirements for flares as specified in §§ 63.670 and 63.671, including the provisions in tables 12 and 13 to subpart CC of this part, except as specified in paragraph (b) of this section. This requirement also applies to any flare using fuel gas from a fuel gas system, of which 50 percent or more of the fuel gas is derived from a EPPU, as determined on an annual average basis. For purposes of compliance with this paragraph, the following terms are defined in § 63.641 of subpart CC of this part: Assist air, assist steam, center steam, combustion zone, combustion zone gas, flare, flare purge gas, flare supplemental gas, flare sweep gas, flare vent gas, lower steam, net heating value, perimeter assist air, pilot gas, premix assist air, total steam, and upper steam.(1) §§ 63.487(a)(1)(i) and (b)(1)(i);(2) § 63.489(b)(2);(3) § 63.490(a)(1);(5) § 63.494(d);(6) § 63.496(b)(7)(i)(A);(7) § 63.497(a)(2);(9) § 63.502(k)(1);(11) § 63.107(h)(9)(i) related to criteria in § 63.11(b);(12) § 63.113(a)(1);(13) § 63.114(a)(2);(16) § 63.118(f)(5);(17) The last sentence in § 63.119(e)(1);(19) §§ 63.122(c)(2) and (g)(3);(20) § 63.126(b)(2)(i);(21) § 63.127(a)(2);(24) §§ 63.130(a)(2)(i), (c), and (d)(5);(25) §§ 63.139(c)(3) and (d)(3);(28) § 63.147(d)(1);(29) §§ 63.172(d);(31) § 63.181(g)(1)(iii); and(32) The phrase “including periods when a flare pilot light system does not have a flame” in § 63.181(g)(2)(i).
Citations to §63.508(a)(14)
-
(a) For any flare that is used to reduce organic HAP emissions from an EPPU, the owner or operator may elect to comply with the requirements in this section in lieu of the requirements of § 63.11(b) and the requirements referenced therein. The owner or operator may also elect to comply with the requirements in this section pursuant to the overlap provisions provided in § 63.481(k)(2). However, beginning no later than the compliance dates specified in § 63.481(n), the provisions specified in paragraphs (a)(1) through (32) of this section no longer apply. Instead, if an owner or operator reduces organic HAP emissions from an EPPU by venting emissions through a closed-vent system to a steam-assisted, air-assisted, or non-assisted flare, then the owner or operator must meet the applicable requirements for flares as specified in §§ 63.670 and 63.671, including the provisions in tables 12 and 13 to subpart CC of this part, except as specified in paragraph (b) of this section. This requirement also applies to any flare using fuel gas from a fuel gas system, of which 50 percent or more of the fuel gas is derived from a EPPU, as determined on an annual average basis. For purposes of compliance with this paragraph, the following terms are defined in § 63.641 of subpart CC of this part: Assist air, assist steam, center steam, combustion zone, combustion zone gas, flare, flare purge gas, flare supplemental gas, flare sweep gas, flare vent gas, lower steam, net heating value, perimeter assist air, pilot gas, premix assist air, total steam, and upper steam.(1) §§ 63.487(a)(1)(i) and (b)(1)(i);(2) § 63.489(b)(2);(3) § 63.490(a)(1);(5) § 63.494(d);(6) § 63.496(b)(7)(i)(A);(7) § 63.497(a)(2);(9) § 63.502(k)(1);(11) § 63.107(h)(9)(i) related to criteria in § 63.11(b);(12) § 63.113(a)(1);(13) § 63.114(a)(2);(16) § 63.118(f)(5);(17) The last sentence in § 63.119(e)(1);(19) §§ 63.122(c)(2) and (g)(3);(20) § 63.126(b)(2)(i);(21) § 63.127(a)(2);(24) §§ 63.130(a)(2)(i), (c), and (d)(5);(25) §§ 63.139(c)(3) and (d)(3);(28) § 63.147(d)(1);(29) §§ 63.172(d);(31) § 63.181(g)(1)(iii); and(32) The phrase “including periods when a flare pilot light system does not have a flame” in § 63.181(g)(2)(i).
Citations to §63.508(a)(15)
-
(a) For any flare that is used to reduce organic HAP emissions from an EPPU, the owner or operator may elect to comply with the requirements in this section in lieu of the requirements of § 63.11(b) and the requirements referenced therein. The owner or operator may also elect to comply with the requirements in this section pursuant to the overlap provisions provided in § 63.481(k)(2). However, beginning no later than the compliance dates specified in § 63.481(n), the provisions specified in paragraphs (a)(1) through (32) of this section no longer apply. Instead, if an owner or operator reduces organic HAP emissions from an EPPU by venting emissions through a closed-vent system to a steam-assisted, air-assisted, or non-assisted flare, then the owner or operator must meet the applicable requirements for flares as specified in §§ 63.670 and 63.671, including the provisions in tables 12 and 13 to subpart CC of this part, except as specified in paragraph (b) of this section. This requirement also applies to any flare using fuel gas from a fuel gas system, of which 50 percent or more of the fuel gas is derived from a EPPU, as determined on an annual average basis. For purposes of compliance with this paragraph, the following terms are defined in § 63.641 of subpart CC of this part: Assist air, assist steam, center steam, combustion zone, combustion zone gas, flare, flare purge gas, flare supplemental gas, flare sweep gas, flare vent gas, lower steam, net heating value, perimeter assist air, pilot gas, premix assist air, total steam, and upper steam.(1) §§ 63.487(a)(1)(i) and (b)(1)(i);(2) § 63.489(b)(2);(3) § 63.490(a)(1);(5) § 63.494(d);(6) § 63.496(b)(7)(i)(A);(7) § 63.497(a)(2);(9) § 63.502(k)(1);(11) § 63.107(h)(9)(i) related to criteria in § 63.11(b);(12) § 63.113(a)(1);(13) § 63.114(a)(2);(16) § 63.118(f)(5);(17) The last sentence in § 63.119(e)(1);(19) §§ 63.122(c)(2) and (g)(3);(20) § 63.126(b)(2)(i);(21) § 63.127(a)(2);(24) §§ 63.130(a)(2)(i), (c), and (d)(5);(25) §§ 63.139(c)(3) and (d)(3);(28) § 63.147(d)(1);(29) §§ 63.172(d);(31) § 63.181(g)(1)(iii); and(32) The phrase “including periods when a flare pilot light system does not have a flame” in § 63.181(g)(2)(i).
Citations to §63.508(a)(16)
-
(a) For any flare that is used to reduce organic HAP emissions from an EPPU, the owner or operator may elect to comply with the requirements in this section in lieu of the requirements of § 63.11(b) and the requirements referenced therein. The owner or operator may also elect to comply with the requirements in this section pursuant to the overlap provisions provided in § 63.481(k)(2). However, beginning no later than the compliance dates specified in § 63.481(n), the provisions specified in paragraphs (a)(1) through (32) of this section no longer apply. Instead, if an owner or operator reduces organic HAP emissions from an EPPU by venting emissions through a closed-vent system to a steam-assisted, air-assisted, or non-assisted flare, then the owner or operator must meet the applicable requirements for flares as specified in §§ 63.670 and 63.671, including the provisions in tables 12 and 13 to subpart CC of this part, except as specified in paragraph (b) of this section. This requirement also applies to any flare using fuel gas from a fuel gas system, of which 50 percent or more of the fuel gas is derived from a EPPU, as determined on an annual average basis. For purposes of compliance with this paragraph, the following terms are defined in § 63.641 of subpart CC of this part: Assist air, assist steam, center steam, combustion zone, combustion zone gas, flare, flare purge gas, flare supplemental gas, flare sweep gas, flare vent gas, lower steam, net heating value, perimeter assist air, pilot gas, premix assist air, total steam, and upper steam.(1) §§ 63.487(a)(1)(i) and (b)(1)(i);(2) § 63.489(b)(2);(3) § 63.490(a)(1);(5) § 63.494(d);(6) § 63.496(b)(7)(i)(A);(7) § 63.497(a)(2);(9) § 63.502(k)(1);(11) § 63.107(h)(9)(i) related to criteria in § 63.11(b);(12) § 63.113(a)(1);(13) § 63.114(a)(2);(16) § 63.118(f)(5);(17) The last sentence in § 63.119(e)(1);(19) §§ 63.122(c)(2) and (g)(3);(20) § 63.126(b)(2)(i);(21) § 63.127(a)(2);(24) §§ 63.130(a)(2)(i), (c), and (d)(5);(25) §§ 63.139(c)(3) and (d)(3);(28) § 63.147(d)(1);(29) §§ 63.172(d);(31) § 63.181(g)(1)(iii); and(32) The phrase “including periods when a flare pilot light system does not have a flame” in § 63.181(g)(2)(i).
Citations to §63.508(a)(17)
-
(a) For any flare that is used to reduce organic HAP emissions from an EPPU, the owner or operator may elect to comply with the requirements in this section in lieu of the requirements of § 63.11(b) and the requirements referenced therein. The owner or operator may also elect to comply with the requirements in this section pursuant to the overlap provisions provided in § 63.481(k)(2). However, beginning no later than the compliance dates specified in § 63.481(n), the provisions specified in paragraphs (a)(1) through (32) of this section no longer apply. Instead, if an owner or operator reduces organic HAP emissions from an EPPU by venting emissions through a closed-vent system to a steam-assisted, air-assisted, or non-assisted flare, then the owner or operator must meet the applicable requirements for flares as specified in §§ 63.670 and 63.671, including the provisions in tables 12 and 13 to subpart CC of this part, except as specified in paragraph (b) of this section. This requirement also applies to any flare using fuel gas from a fuel gas system, of which 50 percent or more of the fuel gas is derived from a EPPU, as determined on an annual average basis. For purposes of compliance with this paragraph, the following terms are defined in § 63.641 of subpart CC of this part: Assist air, assist steam, center steam, combustion zone, combustion zone gas, flare, flare purge gas, flare supplemental gas, flare sweep gas, flare vent gas, lower steam, net heating value, perimeter assist air, pilot gas, premix assist air, total steam, and upper steam.(1) §§ 63.487(a)(1)(i) and (b)(1)(i);(2) § 63.489(b)(2);(3) § 63.490(a)(1);(5) § 63.494(d);(6) § 63.496(b)(7)(i)(A);(7) § 63.497(a)(2);(9) § 63.502(k)(1);(11) § 63.107(h)(9)(i) related to criteria in § 63.11(b);(12) § 63.113(a)(1);(13) § 63.114(a)(2);(16) § 63.118(f)(5);(17) The last sentence in § 63.119(e)(1);(19) §§ 63.122(c)(2) and (g)(3);(20) § 63.126(b)(2)(i);(21) § 63.127(a)(2);(24) §§ 63.130(a)(2)(i), (c), and (d)(5);(25) §§ 63.139(c)(3) and (d)(3);(28) § 63.147(d)(1);(29) §§ 63.172(d);(31) § 63.181(g)(1)(iii); and(32) The phrase “including periods when a flare pilot light system does not have a flame” in § 63.181(g)(2)(i).
Citations to §63.508(a)(18)
-
(a) For any flare that is used to reduce organic HAP emissions from an EPPU, the owner or operator may elect to comply with the requirements in this section in lieu of the requirements of § 63.11(b) and the requirements referenced therein. The owner or operator may also elect to comply with the requirements in this section pursuant to the overlap provisions provided in § 63.481(k)(2). However, beginning no later than the compliance dates specified in § 63.481(n), the provisions specified in paragraphs (a)(1) through (32) of this section no longer apply. Instead, if an owner or operator reduces organic HAP emissions from an EPPU by venting emissions through a closed-vent system to a steam-assisted, air-assisted, or non-assisted flare, then the owner or operator must meet the applicable requirements for flares as specified in §§ 63.670 and 63.671, including the provisions in tables 12 and 13 to subpart CC of this part, except as specified in paragraph (b) of this section. This requirement also applies to any flare using fuel gas from a fuel gas system, of which 50 percent or more of the fuel gas is derived from a EPPU, as determined on an annual average basis. For purposes of compliance with this paragraph, the following terms are defined in § 63.641 of subpart CC of this part: Assist air, assist steam, center steam, combustion zone, combustion zone gas, flare, flare purge gas, flare supplemental gas, flare sweep gas, flare vent gas, lower steam, net heating value, perimeter assist air, pilot gas, premix assist air, total steam, and upper steam.(1) §§ 63.487(a)(1)(i) and (b)(1)(i);(2) § 63.489(b)(2);(3) § 63.490(a)(1);(5) § 63.494(d);(6) § 63.496(b)(7)(i)(A);(7) § 63.497(a)(2);(9) § 63.502(k)(1);(11) § 63.107(h)(9)(i) related to criteria in § 63.11(b);(12) § 63.113(a)(1);(13) § 63.114(a)(2);(16) § 63.118(f)(5);(17) The last sentence in § 63.119(e)(1);(19) §§ 63.122(c)(2) and (g)(3);(20) § 63.126(b)(2)(i);(21) § 63.127(a)(2);(24) §§ 63.130(a)(2)(i), (c), and (d)(5);(25) §§ 63.139(c)(3) and (d)(3);(28) § 63.147(d)(1);(29) §§ 63.172(d);(31) § 63.181(g)(1)(iii); and(32) The phrase “including periods when a flare pilot light system does not have a flame” in § 63.181(g)(2)(i).
Citations to §63.508(a)(19)
-
(a) For any flare that is used to reduce organic HAP emissions from an EPPU, the owner or operator may elect to comply with the requirements in this section in lieu of the requirements of § 63.11(b) and the requirements referenced therein. The owner or operator may also elect to comply with the requirements in this section pursuant to the overlap provisions provided in § 63.481(k)(2). However, beginning no later than the compliance dates specified in § 63.481(n), the provisions specified in paragraphs (a)(1) through (32) of this section no longer apply. Instead, if an owner or operator reduces organic HAP emissions from an EPPU by venting emissions through a closed-vent system to a steam-assisted, air-assisted, or non-assisted flare, then the owner or operator must meet the applicable requirements for flares as specified in §§ 63.670 and 63.671, including the provisions in tables 12 and 13 to subpart CC of this part, except as specified in paragraph (b) of this section. This requirement also applies to any flare using fuel gas from a fuel gas system, of which 50 percent or more of the fuel gas is derived from a EPPU, as determined on an annual average basis. For purposes of compliance with this paragraph, the following terms are defined in § 63.641 of subpart CC of this part: Assist air, assist steam, center steam, combustion zone, combustion zone gas, flare, flare purge gas, flare supplemental gas, flare sweep gas, flare vent gas, lower steam, net heating value, perimeter assist air, pilot gas, premix assist air, total steam, and upper steam.(1) §§ 63.487(a)(1)(i) and (b)(1)(i);(2) § 63.489(b)(2);(3) § 63.490(a)(1);(5) § 63.494(d);(6) § 63.496(b)(7)(i)(A);(7) § 63.497(a)(2);(9) § 63.502(k)(1);(11) § 63.107(h)(9)(i) related to criteria in § 63.11(b);(12) § 63.113(a)(1);(13) § 63.114(a)(2);(16) § 63.118(f)(5);(17) The last sentence in § 63.119(e)(1);(19) §§ 63.122(c)(2) and (g)(3);(20) § 63.126(b)(2)(i);(21) § 63.127(a)(2);(24) §§ 63.130(a)(2)(i), (c), and (d)(5);(25) §§ 63.139(c)(3) and (d)(3);(28) § 63.147(d)(1);(29) §§ 63.172(d);(31) § 63.181(g)(1)(iii); and(32) The phrase “including periods when a flare pilot light system does not have a flame” in § 63.181(g)(2)(i).
Citations to §63.508(a)(20)
-
(a) For any flare that is used to reduce organic HAP emissions from an EPPU, the owner or operator may elect to comply with the requirements in this section in lieu of the requirements of § 63.11(b) and the requirements referenced therein. The owner or operator may also elect to comply with the requirements in this section pursuant to the overlap provisions provided in § 63.481(k)(2). However, beginning no later than the compliance dates specified in § 63.481(n), the provisions specified in paragraphs (a)(1) through (32) of this section no longer apply. Instead, if an owner or operator reduces organic HAP emissions from an EPPU by venting emissions through a closed-vent system to a steam-assisted, air-assisted, or non-assisted flare, then the owner or operator must meet the applicable requirements for flares as specified in §§ 63.670 and 63.671, including the provisions in tables 12 and 13 to subpart CC of this part, except as specified in paragraph (b) of this section. This requirement also applies to any flare using fuel gas from a fuel gas system, of which 50 percent or more of the fuel gas is derived from a EPPU, as determined on an annual average basis. For purposes of compliance with this paragraph, the following terms are defined in § 63.641 of subpart CC of this part: Assist air, assist steam, center steam, combustion zone, combustion zone gas, flare, flare purge gas, flare supplemental gas, flare sweep gas, flare vent gas, lower steam, net heating value, perimeter assist air, pilot gas, premix assist air, total steam, and upper steam.(1) §§ 63.487(a)(1)(i) and (b)(1)(i);(2) § 63.489(b)(2);(3) § 63.490(a)(1);(5) § 63.494(d);(6) § 63.496(b)(7)(i)(A);(7) § 63.497(a)(2);(9) § 63.502(k)(1);(11) § 63.107(h)(9)(i) related to criteria in § 63.11(b);(12) § 63.113(a)(1);(13) § 63.114(a)(2);(16) § 63.118(f)(5);(17) The last sentence in § 63.119(e)(1);(19) §§ 63.122(c)(2) and (g)(3);(20) § 63.126(b)(2)(i);(21) § 63.127(a)(2);(24) §§ 63.130(a)(2)(i), (c), and (d)(5);(25) §§ 63.139(c)(3) and (d)(3);(28) § 63.147(d)(1);(29) §§ 63.172(d);(31) § 63.181(g)(1)(iii); and(32) The phrase “including periods when a flare pilot light system does not have a flame” in § 63.181(g)(2)(i).
Citations to §63.508(a)(21)
-
(a) For any flare that is used to reduce organic HAP emissions from an EPPU, the owner or operator may elect to comply with the requirements in this section in lieu of the requirements of § 63.11(b) and the requirements referenced therein. The owner or operator may also elect to comply with the requirements in this section pursuant to the overlap provisions provided in § 63.481(k)(2). However, beginning no later than the compliance dates specified in § 63.481(n), the provisions specified in paragraphs (a)(1) through (32) of this section no longer apply. Instead, if an owner or operator reduces organic HAP emissions from an EPPU by venting emissions through a closed-vent system to a steam-assisted, air-assisted, or non-assisted flare, then the owner or operator must meet the applicable requirements for flares as specified in §§ 63.670 and 63.671, including the provisions in tables 12 and 13 to subpart CC of this part, except as specified in paragraph (b) of this section. This requirement also applies to any flare using fuel gas from a fuel gas system, of which 50 percent or more of the fuel gas is derived from a EPPU, as determined on an annual average basis. For purposes of compliance with this paragraph, the following terms are defined in § 63.641 of subpart CC of this part: Assist air, assist steam, center steam, combustion zone, combustion zone gas, flare, flare purge gas, flare supplemental gas, flare sweep gas, flare vent gas, lower steam, net heating value, perimeter assist air, pilot gas, premix assist air, total steam, and upper steam.(1) §§ 63.487(a)(1)(i) and (b)(1)(i);(2) § 63.489(b)(2);(3) § 63.490(a)(1);(5) § 63.494(d);(6) § 63.496(b)(7)(i)(A);(7) § 63.497(a)(2);(9) § 63.502(k)(1);(11) § 63.107(h)(9)(i) related to criteria in § 63.11(b);(12) § 63.113(a)(1);(13) § 63.114(a)(2);(16) § 63.118(f)(5);(17) The last sentence in § 63.119(e)(1);(19) §§ 63.122(c)(2) and (g)(3);(20) § 63.126(b)(2)(i);(21) § 63.127(a)(2);(24) §§ 63.130(a)(2)(i), (c), and (d)(5);(25) §§ 63.139(c)(3) and (d)(3);(28) § 63.147(d)(1);(29) §§ 63.172(d);(31) § 63.181(g)(1)(iii); and(32) The phrase “including periods when a flare pilot light system does not have a flame” in § 63.181(g)(2)(i).
Citations to §63.508(a)(22)
-
(a) For any flare that is used to reduce organic HAP emissions from an EPPU, the owner or operator may elect to comply with the requirements in this section in lieu of the requirements of § 63.11(b) and the requirements referenced therein. The owner or operator may also elect to comply with the requirements in this section pursuant to the overlap provisions provided in § 63.481(k)(2). However, beginning no later than the compliance dates specified in § 63.481(n), the provisions specified in paragraphs (a)(1) through (32) of this section no longer apply. Instead, if an owner or operator reduces organic HAP emissions from an EPPU by venting emissions through a closed-vent system to a steam-assisted, air-assisted, or non-assisted flare, then the owner or operator must meet the applicable requirements for flares as specified in §§ 63.670 and 63.671, including the provisions in tables 12 and 13 to subpart CC of this part, except as specified in paragraph (b) of this section. This requirement also applies to any flare using fuel gas from a fuel gas system, of which 50 percent or more of the fuel gas is derived from a EPPU, as determined on an annual average basis. For purposes of compliance with this paragraph, the following terms are defined in § 63.641 of subpart CC of this part: Assist air, assist steam, center steam, combustion zone, combustion zone gas, flare, flare purge gas, flare supplemental gas, flare sweep gas, flare vent gas, lower steam, net heating value, perimeter assist air, pilot gas, premix assist air, total steam, and upper steam.(1) §§ 63.487(a)(1)(i) and (b)(1)(i);(2) § 63.489(b)(2);(3) § 63.490(a)(1);(5) § 63.494(d);(6) § 63.496(b)(7)(i)(A);(7) § 63.497(a)(2);(9) § 63.502(k)(1);(11) § 63.107(h)(9)(i) related to criteria in § 63.11(b);(12) § 63.113(a)(1);(13) § 63.114(a)(2);(16) § 63.118(f)(5);(17) The last sentence in § 63.119(e)(1);(19) §§ 63.122(c)(2) and (g)(3);(20) § 63.126(b)(2)(i);(21) § 63.127(a)(2);(24) §§ 63.130(a)(2)(i), (c), and (d)(5);(25) §§ 63.139(c)(3) and (d)(3);(28) § 63.147(d)(1);(29) §§ 63.172(d);(31) § 63.181(g)(1)(iii); and(32) The phrase “including periods when a flare pilot light system does not have a flame” in § 63.181(g)(2)(i).
Citations to §63.508(a)(23)
-
(a) For any flare that is used to reduce organic HAP emissions from an EPPU, the owner or operator may elect to comply with the requirements in this section in lieu of the requirements of § 63.11(b) and the requirements referenced therein. The owner or operator may also elect to comply with the requirements in this section pursuant to the overlap provisions provided in § 63.481(k)(2). However, beginning no later than the compliance dates specified in § 63.481(n), the provisions specified in paragraphs (a)(1) through (32) of this section no longer apply. Instead, if an owner or operator reduces organic HAP emissions from an EPPU by venting emissions through a closed-vent system to a steam-assisted, air-assisted, or non-assisted flare, then the owner or operator must meet the applicable requirements for flares as specified in §§ 63.670 and 63.671, including the provisions in tables 12 and 13 to subpart CC of this part, except as specified in paragraph (b) of this section. This requirement also applies to any flare using fuel gas from a fuel gas system, of which 50 percent or more of the fuel gas is derived from a EPPU, as determined on an annual average basis. For purposes of compliance with this paragraph, the following terms are defined in § 63.641 of subpart CC of this part: Assist air, assist steam, center steam, combustion zone, combustion zone gas, flare, flare purge gas, flare supplemental gas, flare sweep gas, flare vent gas, lower steam, net heating value, perimeter assist air, pilot gas, premix assist air, total steam, and upper steam.(1) §§ 63.487(a)(1)(i) and (b)(1)(i);(2) § 63.489(b)(2);(3) § 63.490(a)(1);(5) § 63.494(d);(6) § 63.496(b)(7)(i)(A);(7) § 63.497(a)(2);(9) § 63.502(k)(1);(11) § 63.107(h)(9)(i) related to criteria in § 63.11(b);(12) § 63.113(a)(1);(13) § 63.114(a)(2);(16) § 63.118(f)(5);(17) The last sentence in § 63.119(e)(1);(19) §§ 63.122(c)(2) and (g)(3);(20) § 63.126(b)(2)(i);(21) § 63.127(a)(2);(24) §§ 63.130(a)(2)(i), (c), and (d)(5);(25) §§ 63.139(c)(3) and (d)(3);(28) § 63.147(d)(1);(29) §§ 63.172(d);(31) § 63.181(g)(1)(iii); and(32) The phrase “including periods when a flare pilot light system does not have a flame” in § 63.181(g)(2)(i).
Citations to §63.508(a)(24)
-
(a) For any flare that is used to reduce organic HAP emissions from an EPPU, the owner or operator may elect to comply with the requirements in this section in lieu of the requirements of § 63.11(b) and the requirements referenced therein. The owner or operator may also elect to comply with the requirements in this section pursuant to the overlap provisions provided in § 63.481(k)(2). However, beginning no later than the compliance dates specified in § 63.481(n), the provisions specified in paragraphs (a)(1) through (32) of this section no longer apply. Instead, if an owner or operator reduces organic HAP emissions from an EPPU by venting emissions through a closed-vent system to a steam-assisted, air-assisted, or non-assisted flare, then the owner or operator must meet the applicable requirements for flares as specified in §§ 63.670 and 63.671, including the provisions in tables 12 and 13 to subpart CC of this part, except as specified in paragraph (b) of this section. This requirement also applies to any flare using fuel gas from a fuel gas system, of which 50 percent or more of the fuel gas is derived from a EPPU, as determined on an annual average basis. For purposes of compliance with this paragraph, the following terms are defined in § 63.641 of subpart CC of this part: Assist air, assist steam, center steam, combustion zone, combustion zone gas, flare, flare purge gas, flare supplemental gas, flare sweep gas, flare vent gas, lower steam, net heating value, perimeter assist air, pilot gas, premix assist air, total steam, and upper steam.(1) §§ 63.487(a)(1)(i) and (b)(1)(i);(2) § 63.489(b)(2);(3) § 63.490(a)(1);(5) § 63.494(d);(6) § 63.496(b)(7)(i)(A);(7) § 63.497(a)(2);(9) § 63.502(k)(1);(11) § 63.107(h)(9)(i) related to criteria in § 63.11(b);(12) § 63.113(a)(1);(13) § 63.114(a)(2);(16) § 63.118(f)(5);(17) The last sentence in § 63.119(e)(1);(19) §§ 63.122(c)(2) and (g)(3);(20) § 63.126(b)(2)(i);(21) § 63.127(a)(2);(24) §§ 63.130(a)(2)(i), (c), and (d)(5);(25) §§ 63.139(c)(3) and (d)(3);(28) § 63.147(d)(1);(29) §§ 63.172(d);(31) § 63.181(g)(1)(iii); and(32) The phrase “including periods when a flare pilot light system does not have a flame” in § 63.181(g)(2)(i).
Citations to §63.508(a)(25)
-
(a) For any flare that is used to reduce organic HAP emissions from an EPPU, the owner or operator may elect to comply with the requirements in this section in lieu of the requirements of § 63.11(b) and the requirements referenced therein. The owner or operator may also elect to comply with the requirements in this section pursuant to the overlap provisions provided in § 63.481(k)(2). However, beginning no later than the compliance dates specified in § 63.481(n), the provisions specified in paragraphs (a)(1) through (32) of this section no longer apply. Instead, if an owner or operator reduces organic HAP emissions from an EPPU by venting emissions through a closed-vent system to a steam-assisted, air-assisted, or non-assisted flare, then the owner or operator must meet the applicable requirements for flares as specified in §§ 63.670 and 63.671, including the provisions in tables 12 and 13 to subpart CC of this part, except as specified in paragraph (b) of this section. This requirement also applies to any flare using fuel gas from a fuel gas system, of which 50 percent or more of the fuel gas is derived from a EPPU, as determined on an annual average basis. For purposes of compliance with this paragraph, the following terms are defined in § 63.641 of subpart CC of this part: Assist air, assist steam, center steam, combustion zone, combustion zone gas, flare, flare purge gas, flare supplemental gas, flare sweep gas, flare vent gas, lower steam, net heating value, perimeter assist air, pilot gas, premix assist air, total steam, and upper steam.(1) §§ 63.487(a)(1)(i) and (b)(1)(i);(2) § 63.489(b)(2);(3) § 63.490(a)(1);(5) § 63.494(d);(6) § 63.496(b)(7)(i)(A);(7) § 63.497(a)(2);(9) § 63.502(k)(1);(11) § 63.107(h)(9)(i) related to criteria in § 63.11(b);(12) § 63.113(a)(1);(13) § 63.114(a)(2);(16) § 63.118(f)(5);(17) The last sentence in § 63.119(e)(1);(19) §§ 63.122(c)(2) and (g)(3);(20) § 63.126(b)(2)(i);(21) § 63.127(a)(2);(24) §§ 63.130(a)(2)(i), (c), and (d)(5);(25) §§ 63.139(c)(3) and (d)(3);(28) § 63.147(d)(1);(29) §§ 63.172(d);(31) § 63.181(g)(1)(iii); and(32) The phrase “including periods when a flare pilot light system does not have a flame” in § 63.181(g)(2)(i).
Citations to §63.508(a)(26)
-
(a) For any flare that is used to reduce organic HAP emissions from an EPPU, the owner or operator may elect to comply with the requirements in this section in lieu of the requirements of § 63.11(b) and the requirements referenced therein. The owner or operator may also elect to comply with the requirements in this section pursuant to the overlap provisions provided in § 63.481(k)(2). However, beginning no later than the compliance dates specified in § 63.481(n), the provisions specified in paragraphs (a)(1) through (32) of this section no longer apply. Instead, if an owner or operator reduces organic HAP emissions from an EPPU by venting emissions through a closed-vent system to a steam-assisted, air-assisted, or non-assisted flare, then the owner or operator must meet the applicable requirements for flares as specified in §§ 63.670 and 63.671, including the provisions in tables 12 and 13 to subpart CC of this part, except as specified in paragraph (b) of this section. This requirement also applies to any flare using fuel gas from a fuel gas system, of which 50 percent or more of the fuel gas is derived from a EPPU, as determined on an annual average basis. For purposes of compliance with this paragraph, the following terms are defined in § 63.641 of subpart CC of this part: Assist air, assist steam, center steam, combustion zone, combustion zone gas, flare, flare purge gas, flare supplemental gas, flare sweep gas, flare vent gas, lower steam, net heating value, perimeter assist air, pilot gas, premix assist air, total steam, and upper steam.(1) §§ 63.487(a)(1)(i) and (b)(1)(i);(2) § 63.489(b)(2);(3) § 63.490(a)(1);(5) § 63.494(d);(6) § 63.496(b)(7)(i)(A);(7) § 63.497(a)(2);(9) § 63.502(k)(1);(11) § 63.107(h)(9)(i) related to criteria in § 63.11(b);(12) § 63.113(a)(1);(13) § 63.114(a)(2);(16) § 63.118(f)(5);(17) The last sentence in § 63.119(e)(1);(19) §§ 63.122(c)(2) and (g)(3);(20) § 63.126(b)(2)(i);(21) § 63.127(a)(2);(24) §§ 63.130(a)(2)(i), (c), and (d)(5);(25) §§ 63.139(c)(3) and (d)(3);(28) § 63.147(d)(1);(29) §§ 63.172(d);(31) § 63.181(g)(1)(iii); and(32) The phrase “including periods when a flare pilot light system does not have a flame” in § 63.181(g)(2)(i).
Citations to §63.508(a)(27)
-
(a) For any flare that is used to reduce organic HAP emissions from an EPPU, the owner or operator may elect to comply with the requirements in this section in lieu of the requirements of § 63.11(b) and the requirements referenced therein. The owner or operator may also elect to comply with the requirements in this section pursuant to the overlap provisions provided in § 63.481(k)(2). However, beginning no later than the compliance dates specified in § 63.481(n), the provisions specified in paragraphs (a)(1) through (32) of this section no longer apply. Instead, if an owner or operator reduces organic HAP emissions from an EPPU by venting emissions through a closed-vent system to a steam-assisted, air-assisted, or non-assisted flare, then the owner or operator must meet the applicable requirements for flares as specified in §§ 63.670 and 63.671, including the provisions in tables 12 and 13 to subpart CC of this part, except as specified in paragraph (b) of this section. This requirement also applies to any flare using fuel gas from a fuel gas system, of which 50 percent or more of the fuel gas is derived from a EPPU, as determined on an annual average basis. For purposes of compliance with this paragraph, the following terms are defined in § 63.641 of subpart CC of this part: Assist air, assist steam, center steam, combustion zone, combustion zone gas, flare, flare purge gas, flare supplemental gas, flare sweep gas, flare vent gas, lower steam, net heating value, perimeter assist air, pilot gas, premix assist air, total steam, and upper steam.(1) §§ 63.487(a)(1)(i) and (b)(1)(i);(2) § 63.489(b)(2);(3) § 63.490(a)(1);(5) § 63.494(d);(6) § 63.496(b)(7)(i)(A);(7) § 63.497(a)(2);(9) § 63.502(k)(1);(11) § 63.107(h)(9)(i) related to criteria in § 63.11(b);(12) § 63.113(a)(1);(13) § 63.114(a)(2);(16) § 63.118(f)(5);(17) The last sentence in § 63.119(e)(1);(19) §§ 63.122(c)(2) and (g)(3);(20) § 63.126(b)(2)(i);(21) § 63.127(a)(2);(24) §§ 63.130(a)(2)(i), (c), and (d)(5);(25) §§ 63.139(c)(3) and (d)(3);(28) § 63.147(d)(1);(29) §§ 63.172(d);(31) § 63.181(g)(1)(iii); and(32) The phrase “including periods when a flare pilot light system does not have a flame” in § 63.181(g)(2)(i).
Citations to §63.508(a)(28)
-
(a) For any flare that is used to reduce organic HAP emissions from an EPPU, the owner or operator may elect to comply with the requirements in this section in lieu of the requirements of § 63.11(b) and the requirements referenced therein. The owner or operator may also elect to comply with the requirements in this section pursuant to the overlap provisions provided in § 63.481(k)(2). However, beginning no later than the compliance dates specified in § 63.481(n), the provisions specified in paragraphs (a)(1) through (32) of this section no longer apply. Instead, if an owner or operator reduces organic HAP emissions from an EPPU by venting emissions through a closed-vent system to a steam-assisted, air-assisted, or non-assisted flare, then the owner or operator must meet the applicable requirements for flares as specified in §§ 63.670 and 63.671, including the provisions in tables 12 and 13 to subpart CC of this part, except as specified in paragraph (b) of this section. This requirement also applies to any flare using fuel gas from a fuel gas system, of which 50 percent or more of the fuel gas is derived from a EPPU, as determined on an annual average basis. For purposes of compliance with this paragraph, the following terms are defined in § 63.641 of subpart CC of this part: Assist air, assist steam, center steam, combustion zone, combustion zone gas, flare, flare purge gas, flare supplemental gas, flare sweep gas, flare vent gas, lower steam, net heating value, perimeter assist air, pilot gas, premix assist air, total steam, and upper steam.(1) §§ 63.487(a)(1)(i) and (b)(1)(i);(2) § 63.489(b)(2);(3) § 63.490(a)(1);(5) § 63.494(d);(6) § 63.496(b)(7)(i)(A);(7) § 63.497(a)(2);(9) § 63.502(k)(1);(11) § 63.107(h)(9)(i) related to criteria in § 63.11(b);(12) § 63.113(a)(1);(13) § 63.114(a)(2);(16) § 63.118(f)(5);(17) The last sentence in § 63.119(e)(1);(19) §§ 63.122(c)(2) and (g)(3);(20) § 63.126(b)(2)(i);(21) § 63.127(a)(2);(24) §§ 63.130(a)(2)(i), (c), and (d)(5);(25) §§ 63.139(c)(3) and (d)(3);(28) § 63.147(d)(1);(29) §§ 63.172(d);(31) § 63.181(g)(1)(iii); and(32) The phrase “including periods when a flare pilot light system does not have a flame” in § 63.181(g)(2)(i).
Citations to §63.508(a)(29)
-
(a) For any flare that is used to reduce organic HAP emissions from an EPPU, the owner or operator may elect to comply with the requirements in this section in lieu of the requirements of § 63.11(b) and the requirements referenced therein. The owner or operator may also elect to comply with the requirements in this section pursuant to the overlap provisions provided in § 63.481(k)(2). However, beginning no later than the compliance dates specified in § 63.481(n), the provisions specified in paragraphs (a)(1) through (32) of this section no longer apply. Instead, if an owner or operator reduces organic HAP emissions from an EPPU by venting emissions through a closed-vent system to a steam-assisted, air-assisted, or non-assisted flare, then the owner or operator must meet the applicable requirements for flares as specified in §§ 63.670 and 63.671, including the provisions in tables 12 and 13 to subpart CC of this part, except as specified in paragraph (b) of this section. This requirement also applies to any flare using fuel gas from a fuel gas system, of which 50 percent or more of the fuel gas is derived from a EPPU, as determined on an annual average basis. For purposes of compliance with this paragraph, the following terms are defined in § 63.641 of subpart CC of this part: Assist air, assist steam, center steam, combustion zone, combustion zone gas, flare, flare purge gas, flare supplemental gas, flare sweep gas, flare vent gas, lower steam, net heating value, perimeter assist air, pilot gas, premix assist air, total steam, and upper steam.(1) §§ 63.487(a)(1)(i) and (b)(1)(i);(2) § 63.489(b)(2);(3) § 63.490(a)(1);(5) § 63.494(d);(6) § 63.496(b)(7)(i)(A);(7) § 63.497(a)(2);(9) § 63.502(k)(1);(11) § 63.107(h)(9)(i) related to criteria in § 63.11(b);(12) § 63.113(a)(1);(13) § 63.114(a)(2);(16) § 63.118(f)(5);(17) The last sentence in § 63.119(e)(1);(19) §§ 63.122(c)(2) and (g)(3);(20) § 63.126(b)(2)(i);(21) § 63.127(a)(2);(24) §§ 63.130(a)(2)(i), (c), and (d)(5);(25) §§ 63.139(c)(3) and (d)(3);(28) § 63.147(d)(1);(29) §§ 63.172(d);(31) § 63.181(g)(1)(iii); and(32) The phrase “including periods when a flare pilot light system does not have a flame” in § 63.181(g)(2)(i).
Citations to §63.508(a)(30)
-
(a) For any flare that is used to reduce organic HAP emissions from an EPPU, the owner or operator may elect to comply with the requirements in this section in lieu of the requirements of § 63.11(b) and the requirements referenced therein. The owner or operator may also elect to comply with the requirements in this section pursuant to the overlap provisions provided in § 63.481(k)(2). However, beginning no later than the compliance dates specified in § 63.481(n), the provisions specified in paragraphs (a)(1) through (32) of this section no longer apply. Instead, if an owner or operator reduces organic HAP emissions from an EPPU by venting emissions through a closed-vent system to a steam-assisted, air-assisted, or non-assisted flare, then the owner or operator must meet the applicable requirements for flares as specified in §§ 63.670 and 63.671, including the provisions in tables 12 and 13 to subpart CC of this part, except as specified in paragraph (b) of this section. This requirement also applies to any flare using fuel gas from a fuel gas system, of which 50 percent or more of the fuel gas is derived from a EPPU, as determined on an annual average basis. For purposes of compliance with this paragraph, the following terms are defined in § 63.641 of subpart CC of this part: Assist air, assist steam, center steam, combustion zone, combustion zone gas, flare, flare purge gas, flare supplemental gas, flare sweep gas, flare vent gas, lower steam, net heating value, perimeter assist air, pilot gas, premix assist air, total steam, and upper steam.(1) §§ 63.487(a)(1)(i) and (b)(1)(i);(2) § 63.489(b)(2);(3) § 63.490(a)(1);(5) § 63.494(d);(6) § 63.496(b)(7)(i)(A);(7) § 63.497(a)(2);(9) § 63.502(k)(1);(11) § 63.107(h)(9)(i) related to criteria in § 63.11(b);(12) § 63.113(a)(1);(13) § 63.114(a)(2);(16) § 63.118(f)(5);(17) The last sentence in § 63.119(e)(1);(19) §§ 63.122(c)(2) and (g)(3);(20) § 63.126(b)(2)(i);(21) § 63.127(a)(2);(24) §§ 63.130(a)(2)(i), (c), and (d)(5);(25) §§ 63.139(c)(3) and (d)(3);(28) § 63.147(d)(1);(29) §§ 63.172(d);(31) § 63.181(g)(1)(iii); and(32) The phrase “including periods when a flare pilot light system does not have a flame” in § 63.181(g)(2)(i).
Citations to §63.508(a)(31)
-
(a) For any flare that is used to reduce organic HAP emissions from an EPPU, the owner or operator may elect to comply with the requirements in this section in lieu of the requirements of § 63.11(b) and the requirements referenced therein. The owner or operator may also elect to comply with the requirements in this section pursuant to the overlap provisions provided in § 63.481(k)(2). However, beginning no later than the compliance dates specified in § 63.481(n), the provisions specified in paragraphs (a)(1) through (32) of this section no longer apply. Instead, if an owner or operator reduces organic HAP emissions from an EPPU by venting emissions through a closed-vent system to a steam-assisted, air-assisted, or non-assisted flare, then the owner or operator must meet the applicable requirements for flares as specified in §§ 63.670 and 63.671, including the provisions in tables 12 and 13 to subpart CC of this part, except as specified in paragraph (b) of this section. This requirement also applies to any flare using fuel gas from a fuel gas system, of which 50 percent or more of the fuel gas is derived from a EPPU, as determined on an annual average basis. For purposes of compliance with this paragraph, the following terms are defined in § 63.641 of subpart CC of this part: Assist air, assist steam, center steam, combustion zone, combustion zone gas, flare, flare purge gas, flare supplemental gas, flare sweep gas, flare vent gas, lower steam, net heating value, perimeter assist air, pilot gas, premix assist air, total steam, and upper steam.(1) §§ 63.487(a)(1)(i) and (b)(1)(i);(2) § 63.489(b)(2);(3) § 63.490(a)(1);(5) § 63.494(d);(6) § 63.496(b)(7)(i)(A);(7) § 63.497(a)(2);(9) § 63.502(k)(1);(11) § 63.107(h)(9)(i) related to criteria in § 63.11(b);(12) § 63.113(a)(1);(13) § 63.114(a)(2);(16) § 63.118(f)(5);(17) The last sentence in § 63.119(e)(1);(19) §§ 63.122(c)(2) and (g)(3);(20) § 63.126(b)(2)(i);(21) § 63.127(a)(2);(24) §§ 63.130(a)(2)(i), (c), and (d)(5);(25) §§ 63.139(c)(3) and (d)(3);(28) § 63.147(d)(1);(29) §§ 63.172(d);(31) § 63.181(g)(1)(iii); and(32) The phrase “including periods when a flare pilot light system does not have a flame” in § 63.181(g)(2)(i).
Citations to §63.508(a)(32)
-
(a) For any flare that is used to reduce organic HAP emissions from an EPPU, the owner or operator may elect to comply with the requirements in this section in lieu of the requirements of § 63.11(b) and the requirements referenced therein. The owner or operator may also elect to comply with the requirements in this section pursuant to the overlap provisions provided in § 63.481(k)(2). However, beginning no later than the compliance dates specified in § 63.481(n), the provisions specified in paragraphs (a)(1) through (32) of this section no longer apply. Instead, if an owner or operator reduces organic HAP emissions from an EPPU by venting emissions through a closed-vent system to a steam-assisted, air-assisted, or non-assisted flare, then the owner or operator must meet the applicable requirements for flares as specified in §§ 63.670 and 63.671, including the provisions in tables 12 and 13 to subpart CC of this part, except as specified in paragraph (b) of this section. This requirement also applies to any flare using fuel gas from a fuel gas system, of which 50 percent or more of the fuel gas is derived from a EPPU, as determined on an annual average basis. For purposes of compliance with this paragraph, the following terms are defined in § 63.641 of subpart CC of this part: Assist air, assist steam, center steam, combustion zone, combustion zone gas, flare, flare purge gas, flare supplemental gas, flare sweep gas, flare vent gas, lower steam, net heating value, perimeter assist air, pilot gas, premix assist air, total steam, and upper steam.(1) §§ 63.487(a)(1)(i) and (b)(1)(i);(2) § 63.489(b)(2);(3) § 63.490(a)(1);(5) § 63.494(d);(6) § 63.496(b)(7)(i)(A);(7) § 63.497(a)(2);(9) § 63.502(k)(1);(11) § 63.107(h)(9)(i) related to criteria in § 63.11(b);(12) § 63.113(a)(1);(13) § 63.114(a)(2);(16) § 63.118(f)(5);(17) The last sentence in § 63.119(e)(1);(19) §§ 63.122(c)(2) and (g)(3);(20) § 63.126(b)(2)(i);(21) § 63.127(a)(2);(24) §§ 63.130(a)(2)(i), (c), and (d)(5);(25) §§ 63.139(c)(3) and (d)(3);(28) § 63.147(d)(1);(29) §§ 63.172(d);(31) § 63.181(g)(1)(iii); and(32) The phrase “including periods when a flare pilot light system does not have a flame” in § 63.181(g)(2)(i).
Citations to §63.508(b)(1)
-
(b) The exceptions specified in paragraphs (b) through (o) of § 63.108 apply, except as specified in paragraphs (b)(1) through (5) of this section.(1) Where the term “chemical manufacturing process unit” is used, the term “EPPU” applies instead for the purposes of this subpart.(2) Where the reference “§ 63.100(k)(10)” is used, the reference § 63.481(n) applies instead for the purposes of this subpart.(3) Where the phrase “Hazardous Organic Chemical Manufacturing” is used, the phrase “Polymers and Resins” applies instead for the purposes of this subpart.(4) Where the reference “§ 63.152(b)(7) of subpart G of this part” is used, the reference “§ 63.506(e)(5)(xiii)” applies instead for the purposes of this subpart.(5) Section 63.108(i) does not apply.
Citations to §63.508(b)(2)
-
(b) The exceptions specified in paragraphs (b) through (o) of § 63.108 apply, except as specified in paragraphs (b)(1) through (5) of this section.(1) Where the term “chemical manufacturing process unit” is used, the term “EPPU” applies instead for the purposes of this subpart.(2) Where the reference “§ 63.100(k)(10)” is used, the reference § 63.481(n) applies instead for the purposes of this subpart.(3) Where the phrase “Hazardous Organic Chemical Manufacturing” is used, the phrase “Polymers and Resins” applies instead for the purposes of this subpart.(4) Where the reference “§ 63.152(b)(7) of subpart G of this part” is used, the reference “§ 63.506(e)(5)(xiii)” applies instead for the purposes of this subpart.(5) Section 63.108(i) does not apply.
Citations to §63.508(b)(3)
-
(b) The exceptions specified in paragraphs (b) through (o) of § 63.108 apply, except as specified in paragraphs (b)(1) through (5) of this section.(1) Where the term “chemical manufacturing process unit” is used, the term “EPPU” applies instead for the purposes of this subpart.(2) Where the reference “§ 63.100(k)(10)” is used, the reference § 63.481(n) applies instead for the purposes of this subpart.(3) Where the phrase “Hazardous Organic Chemical Manufacturing” is used, the phrase “Polymers and Resins” applies instead for the purposes of this subpart.(4) Where the reference “§ 63.152(b)(7) of subpart G of this part” is used, the reference “§ 63.506(e)(5)(xiii)” applies instead for the purposes of this subpart.(5) Section 63.108(i) does not apply.
Citations to §63.508(b)(4)
-
(b) The exceptions specified in paragraphs (b) through (o) of § 63.108 apply, except as specified in paragraphs (b)(1) through (5) of this section.(1) Where the term “chemical manufacturing process unit” is used, the term “EPPU” applies instead for the purposes of this subpart.(2) Where the reference “§ 63.100(k)(10)” is used, the reference § 63.481(n) applies instead for the purposes of this subpart.(3) Where the phrase “Hazardous Organic Chemical Manufacturing” is used, the phrase “Polymers and Resins” applies instead for the purposes of this subpart.(4) Where the reference “§ 63.152(b)(7) of subpart G of this part” is used, the reference “§ 63.506(e)(5)(xiii)” applies instead for the purposes of this subpart.(5) Section 63.108(i) does not apply.
Citations to §63.508(b)(5)
-
(b) The exceptions specified in paragraphs (b) through (o) of § 63.108 apply, except as specified in paragraphs (b)(1) through (5) of this section.(1) Where the term “chemical manufacturing process unit” is used, the term “EPPU” applies instead for the purposes of this subpart.(2) Where the reference “§ 63.100(k)(10)” is used, the reference § 63.481(n) applies instead for the purposes of this subpart.(3) Where the phrase “Hazardous Organic Chemical Manufacturing” is used, the phrase “Polymers and Resins” applies instead for the purposes of this subpart.(4) Where the reference “§ 63.152(b)(7) of subpart G of this part” is used, the reference “§ 63.506(e)(5)(xiii)” applies instead for the purposes of this subpart.(5) Section 63.108(i) does not apply.