§63.3360. What performance tests must I conduct?
40 C.F.R. § 63.3360
(1) Annual sampling and analysis of the catalyst activity (i.e., conversion efficiency) following the manufacturer's or catalyst supplier's recommended procedures,
(2) Monthly inspection of the oxidizer system including the burner assembly and fuel supply lines for problems, and
(3) Annual internal and monthly external visual inspection of the catalyst bed to check for channeling, abrasion, and settling. If problems are found, you must take corrective action consistent with the manufacturer's recommendations and conduct a new performance test to determine destruction efficiency in accordance with this section.