  • (c) For each CEMS and brew ethanol monitor, you must keep the records listed in paragraphs (c)(1) through (5) of this section.
    (1) Records described in § 63.10(b)(2)(vi), (vii), (x), and (xi). The CEMS must allow the amount of excess zero (low-level) and high-level calibration drift measured at the interval checks to be quantified and recorded.
    (2) Records described in § 63.10(c)(1) through (6).
    (3) Records of the quality control program as specified in § 63.8(d), including the program of corrective action; the current version of the performance evaluation test plan, as specified in § 63.8(e)(3); and previous (i.e., superseded) versions of the performance evaluation test plan for a period of 5 years after each revision to the plan.
    (4) Requests for alternatives to RATA for CEMS as required in § 63.8(f)(6)(i).
    (5) Records of each deviation from monitoring requirements, including a description of the time period during which the deviation occurred, the nature and cause of the deviation, the corrective action taken or preventive measures adopted, and the nature of repairs or adjustments to the monitoring system.

Citations to §63.2182(c)(2)

  • (c) For each CEMS and brew ethanol monitor, you must keep the records listed in paragraphs (c)(1) through (5) of this section.
    (1) Records described in § 63.10(b)(2)(vi), (vii), (x), and (xi). The CEMS must allow the amount of excess zero (low-level) and high-level calibration drift measured at the interval checks to be quantified and recorded.
    (2) Records described in § 63.10(c)(1) through (6).
    (3) Records of the quality control program as specified in § 63.8(d), including the program of corrective action; the current version of the performance evaluation test plan, as specified in § 63.8(e)(3); and previous (i.e., superseded) versions of the performance evaluation test plan for a period of 5 years after each revision to the plan.
    (4) Requests for alternatives to RATA for CEMS as required in § 63.8(f)(6)(i).
    (5) Records of each deviation from monitoring requirements, including a description of the time period during which the deviation occurred, the nature and cause of the deviation, the corrective action taken or preventive measures adopted, and the nature of repairs or adjustments to the monitoring system.

Citations to §63.2182(c)(3)

  • (c) For each CEMS and brew ethanol monitor, you must keep the records listed in paragraphs (c)(1) through (5) of this section.
    (1) Records described in § 63.10(b)(2)(vi), (vii), (x), and (xi). The CEMS must allow the amount of excess zero (low-level) and high-level calibration drift measured at the interval checks to be quantified and recorded.
    (2) Records described in § 63.10(c)(1) through (6).
    (3) Records of the quality control program as specified in § 63.8(d), including the program of corrective action; the current version of the performance evaluation test plan, as specified in § 63.8(e)(3); and previous (i.e., superseded) versions of the performance evaluation test plan for a period of 5 years after each revision to the plan.
    (4) Requests for alternatives to RATA for CEMS as required in § 63.8(f)(6)(i).
    (5) Records of each deviation from monitoring requirements, including a description of the time period during which the deviation occurred, the nature and cause of the deviation, the corrective action taken or preventive measures adopted, and the nature of repairs or adjustments to the monitoring system.

Citations to §63.2182(c)(4)

  • (c) For each CEMS and brew ethanol monitor, you must keep the records listed in paragraphs (c)(1) through (5) of this section.
    (1) Records described in § 63.10(b)(2)(vi), (vii), (x), and (xi). The CEMS must allow the amount of excess zero (low-level) and high-level calibration drift measured at the interval checks to be quantified and recorded.
    (2) Records described in § 63.10(c)(1) through (6).
    (3) Records of the quality control program as specified in § 63.8(d), including the program of corrective action; the current version of the performance evaluation test plan, as specified in § 63.8(e)(3); and previous (i.e., superseded) versions of the performance evaluation test plan for a period of 5 years after each revision to the plan.
    (4) Requests for alternatives to RATA for CEMS as required in § 63.8(f)(6)(i).
    (5) Records of each deviation from monitoring requirements, including a description of the time period during which the deviation occurred, the nature and cause of the deviation, the corrective action taken or preventive measures adopted, and the nature of repairs or adjustments to the monitoring system.

Citations to §63.2182(c)(5)

  • (c) For each CEMS and brew ethanol monitor, you must keep the records listed in paragraphs (c)(1) through (5) of this section.
    (1) Records described in § 63.10(b)(2)(vi), (vii), (x), and (xi). The CEMS must allow the amount of excess zero (low-level) and high-level calibration drift measured at the interval checks to be quantified and recorded.
    (2) Records described in § 63.10(c)(1) through (6).
    (3) Records of the quality control program as specified in § 63.8(d), including the program of corrective action; the current version of the performance evaluation test plan, as specified in § 63.8(e)(3); and previous (i.e., superseded) versions of the performance evaluation test plan for a period of 5 years after each revision to the plan.
    (4) Requests for alternatives to RATA for CEMS as required in § 63.8(f)(6)(i).
    (5) Records of each deviation from monitoring requirements, including a description of the time period during which the deviation occurred, the nature and cause of the deviation, the corrective action taken or preventive measures adopted, and the nature of repairs or adjustments to the monitoring system.

Citations to §63.2182(e)(1)

Citations to §63.2182(e)(2)

Citations to §63.2182(e)(3)