§63.1282. Test methods, compliance procedures, and compliance demonstrations.
40 C.F.R. § 63.1282
(1) The following equations shall be used:
(2) When the TOC mass rate is calculated, all organic compounds (minus methane and ethane) measured by Method 18, of 40 CFR part 60, appendix A; or Method 25A, 40 CFR part 60, appendix A, shall be summed using the equations in paragraph (d)(3)(iii)(B)(1) of this section.
(3) When the total HAP mass rate is calculated, only HAP chemicals listed in Table 1 of this subpart shall be summed using the equations in paragraph (d)(3)(iii)(B)(1) of this section.
(4) As an alternative to the procedures for calculating Ei specified in paragraph (d)(3)(iii)(B)(1) of this section, the owner or operator may use the model GRI-GLYCalc TM, Version 3.0 or higher, and the procedures presented in the associated GRI-GLYCalc TM Technical Reference Manual. Inputs to the model shall be representative of actual operating conditions of the glycol dehydration unit and shall be determined using the procedures documented in the Gas Research Institute (GRI) report entitled “Atmospheric Rich/Lean Method for Determining Glycol Dehydrator Emissions” (GRI-95/0368.1). When the TOC mass rate is calculated for glycol dehydration units using the model GRI-GLYCalc TM, all organic compounds (minus methane and ethane) measured by Method 18, 40 CFR part 60, appendix A, or Method 25A, 40 CFR part 60, appendix A, shall be summed. When the total HAP mass rate is calculated for glycol dehydration units using the model GRI-GLYCalc TM, only HAP chemicals listed in Table 1 of this subpart shall be summed.
(1) The TOC concentration (CTOC) is the sum of the concentrations of the individual components and shall be computed for each run using the following equation:
(2) The total HAP concentration (CHAP) shall be computed according to the equation in paragraph (d)(3)(iv)(B)(1) of this section, except that only HAP chemicals listed in Table 1 of this subpart shall be summed.
(1) The emission rate correction factor for excess air, integrated sampling and analysis procedures of Method 3A or 3B, 40 CFR part 60, appendix A, ASTM D6522-00 (Reapproved 2005), or ANSI/ASME PTC 19.10-1981, Part 10 (manual portion only) (incorporated by reference as specified in § 63.14) shall be used to determine the oxygen concentration (%O2d). The samples shall be taken during the same time that the samples are taken for determining TOC concentration or total HAP concentration.
(2) The concentration corrected to 3 percent oxygen (Cc) shall be computed using the following equation:
(1) The following equation shall be used:
(2) When the BTEX mass rate is calculated, only BTEX compounds measured by Method 18, 40 CFR part 60, appendix A, or ASTM D6420-99 (Reapproved 2004) (incorporated by reference as specified in § 63.14) as specified in § 63.772(a)(1)(ii), shall be summed using the equations in paragraph (d)(3)(v)(B)(1) of this section.
(1) A control device whose model is tested under, and meets the criteria of, § 63.1282(g), or
(2) A combustion control device demonstrating during the performance test under § 63.1282(d) that combustion zone temperature is an indicator of destruction efficiency and operates at a minimum temperature of 760 degrees C.
(1) Open the canister sampling valve at the beginning of the total hydrocarbon (THC) test, and close the canister at the end of each THC test run.
(2) Fill one canister across the three test runs for each THC test such that one composite fuel sample exists for each test condition.
(3) Label the canisters individually and record on a chain of custody form.
(1) Hydrocarbon compounds containing between one and five atoms of carbon plus benzene using ASTM D1945-03 (Reapproved 2010) (incorporated by reference as specified in § 63.14).
(2) Hydrogen (H2), carbon monoxide (CO), carbon dioxide (CO2), nitrogen (N2), oxygen (O2) using ASTM D1945-03 (Reapproved 2010) (incorporated by reference as specified in § 63.14).
(3) Higher heating value using ASTM D3588-98 (Reapproved 2003) or ASTM D4891-89 (Reapproved 2006) (incorporated by reference as specified in § 63.14).
(1) Collect the integrated sample throughout the entire test, and collect representative volumes from each traverse location.
(2) The sampling line shall be purged with stack gas before opening the valve and beginning to fill the bag.
(3) The bag contents shall be vigorously mixed prior to the GC analysis.
(4) The GC-TCD calibration procedure in Method 3C, 40 CFR part 60, appendix A, shall be modified by using EPAAlt-045 as follows: For the initial calibration, triplicate injections of any single concentration must agree within 5 percent of their mean to be valid. The calibration response factor for a single concentration re-check must be within 10 percent of the original calibration response factor for that concentration. If this criterion is not met, the initial calibration using at least three concentration levels shall be repeated.
Notes, amendments, and revision history
Amendments
[64 FR 32648, June 17, 1999, as amended at 66 FR 34556, June 29, 2001; 77 FR 49588, Aug. 16, 2012]