§63.1189. What test methods do I use?
40 C.F.R. § 63.1189
You must use the following test methods to determine compliance with the applicable emission limits:
Method 1 in appendix A to part 60 of this chapter for the selection of the sampling port locations and number of sampling ports.
Method 2 in appendix A to part 60 of this chapter for stack gas velocity and volumetric flow rate.
Method 3 or 3A in appendix A to part 60 of this chapter for oxygen and carbon dioxide for diluent measurements needed to correct the concentration measurements to a standard basis.
Method 4 in appendix A to part 60 of this chapter for moisture content of the stack gas.
Method 5 in appendix A to part 60 of this chapter for the concentration of PM. Each PM test run must consist of a minimum run time of three hours and a minimum sample volume of 3.75 dscm (135 dscf).
Method 10 in appendix A to part 60 of this chapter for the concentration of CO, using the continuous sampling option described in section 7.1.1 of the method. Each CO test run must consist of a minimum run time of one hour.
Method 318 at 40 CFR part 60, appendix A to this part for the concentration of formaldehyde, phenol, methanol, and carbonyl sulfide.
Method to determine the free-formaldehyde content of each resin lot in appendix A of this subpart.
Method 26A or 320 at 40 CFR part 60, appendix A to this part for the concentration of hydrogen fluoride and hydrogen chloride.
Notes, amendments, and revision history
Amendments
[64 FR 29503, June 1, 1999, as amended at 80 FR 45330, July 29, 2015]
Source
Source: 64 FR 29503, June 1, 1999, unless otherwise noted.
Authority
Authority: 42 U.S.C. 7401 et seq.
Source
Source: 57 FR 61992, Dec. 29, 1992, unless otherwise noted.
Amendments
[64 FR 29503, June 1, 1999, as amended at 80 FR 45330, July 29, 2015]