§63.1177. Am I subject to this subpart?

40 C.F.R. § 63.1177

You are subject to this subpart if you own or operate an existing, new, or reconstructed mineral wool production facility that is located at a plant site that is a major source of hazardous air pollutant (HAP) emissions, meaning the plant emits or has the potential to emit any single HAP at a rate of 9.07 megagrams (10 tons) or more per year or any combination of HAPs at a rate of 22.68 megagrams (25 tons) or more per year.
Notes, amendments, and revision history

Source

Source: 64 FR 29503, June 1, 1999, unless otherwise noted.

Authority

Authority: 42 U.S.C. 7401 et seq.

Source

Source: 57 FR 61992, Dec. 29, 1992, unless otherwise noted.

§63.1178. For cupolas, what standards must I meet?

40 C.F.R. § 63.1178

(a)
You must control emissions from each cupola as specified in Table 2 to this subpart.
(b)
You must meet the following operating limits for each cupola:
(1)
Begin within one hour after the alarm on a bag leak detection system sounds, and complete in a timely manner, corrective actions as specified in your operations, maintenance, and monitoring plan required by § 63.1187 of this subpart.
(2)
When the alarm on a bag leak detection system sounds for more than five percent of the total operating time in a six-month reporting period, develop and implement a written quality improvement plan (QIP) consistent with the compliance assurance monitoring requirements of § 64.8(b)-(d) of 40 CFR part 64.
(3)
Additionally, on or after the applicable compliance date for each new or reconstructed cupola, you must either:
(i)
Maintain the operating temperature of the incinerator so that the average operating temperature for each three-hour block period never falls below the average temperature established during the performance test, or
(ii)
Maintain the percent excess oxygen in the cupola at or above the level established during the performance test. You must determine the percent excess oxygen using the following equation:
Notes, amendments, and revision history

Amendments

[64 FR 29503, June 1, 1999, as amended at 80 FR 45329, July 29, 2015]

Source

Source: 64 FR 29503, June 1, 1999, unless otherwise noted.

Authority

Authority: 42 U.S.C. 7401 et seq.

Source

Source: 57 FR 61992, Dec. 29, 1992, unless otherwise noted.

Amendments

[64 FR 29503, June 1, 1999, as amended at 80 FR 45329, July 29, 2015]

§63.1179. For curing ovens or combined collection/curing operations, what standards must I meet?

40 C.F.R. § 63.1179

(a)
You must control emissions from each curing oven or combined collection/curing operations as specified in Table 2 to this subpart.
(b)
You must meet the following operating limits for each curing oven or combined collection/curing operation:
(1)
Maintain the free-formaldehyde content of each resin lot and the formaldehyde content of each binder formulation at or below the specification ranges of the resin and binder used during the performance test.
(2)
Maintain the operating temperature of each incinerator so that the average operating temperature for each three-hour block period never falls below the average temperature established during the performance test.
Notes, amendments, and revision history

Amendments

[64 FR 29503, June 1, 1999, as amended at 80 FR 45329, July 29, 2015]

Source

Source: 64 FR 29503, June 1, 1999, unless otherwise noted.

Authority

Authority: 42 U.S.C. 7401 et seq.

Source

Source: 57 FR 61992, Dec. 29, 1992, unless otherwise noted.

Amendments

[64 FR 29503, June 1, 1999, as amended at 80 FR 45329, July 29, 2015]

§63.1180. When must I meet these standards?

40 C.F.R. § 63.1180

(a)
Cupolas and curing ovens or combined collection/curing operations. You must comply with the emissions limits specified in Table 2 to this subpart no later than the dates specified in Table 2 to this subpart.
(b)
At all times, you must operate and maintain any affected source, including associated air pollution control equipment and monitoring equipment, in a manner consistent with safety and good air pollution control practices for minimizing emissions. Determination of whether such operation and maintenance procedures are being used will be based on information available to the Administrator which may include, but is not limited to, monitoring results, review of operation and maintenance procedures, review of operation and maintenance records, and inspection of the source.