US Codex
C.F.R.
Browse by date
Notes

§61.149. Standard for waste disposal for asbestos mills. — Inbound Citations

40 C.F.R. § 61.149

Cited by 15 regulations in release Current.

Citations to 40 U.S.C. § 61.149 as a whole

  • The provisions of this subpart are applicable to those sources specified in §§ 61.142 through 61.151, 61.154, and 61.155.
  • (4) For sources subject to §§ 61.149 and 61.150:
    (i) A brief description of each process that generates asbestos-containing waste material; and
    (ii) The average volume of asbestos-containing waste material disposed of, measured in m 3/day (yd 3/day); and
    (iii) The emission control methods used in all stages of waste disposal; and
    (iv) The type of disposal site or incineration site used for ultimate disposal, the name of the site operator, and the name and location of the disposal site.
  • Each owner or operator of an active waste disposal site that receives asbestos-containing waste material from a source covered under § 61.149, 61.150, or 61.155 shall meet the requirements of this section:
  • In addition to this subpart, the regulations referenced in Table 1 also apply to asbestos and may be applicable to those sources specified in §§ 61.142 through 61.151, 61.154, and 61.155 of this subpart. These cross-references are presented for the reader's information and to promote compliance with the cited regulations.

Citations to §61.149(b)

  • (1) Use fabric filter collection devices, except as noted in paragraph (b) of this section, doing all of the following:
    (i) Ensuring that the airflow permeability, as determined by ASTM Method D737-75, does not exceed 9 m 3/min/m 2 (30 ft 3/min/ft 2) for woven fabrics or 11 3/min/m 2(35 ft 3/min/ft 2) for felted fabrics, except that 12 m 3/min/m 2 (40 ft 3min/ft 2) for woven and 14 m 3/min/m 2 (45 ft 3min/ft 2) for felted fabrics is allowed for filtering air from asbestos ore dryers; and
    (ii) Ensuring that felted fabric weighs at least 475 grams per square meter (14 ounces per square yard) and is at least 1.6 millimeters (one-sixteenth inch) thick throughout; and
    (2) Bypass devices may be used only during upset or emergency conditions and then only for so long as it takes to shut down the operation generating the particulate asbestos material.
    (3) For fabric filter collection devices installed after January 10, 1989, provide for easy inspection for faulty bags.

Citations to §61.149(c)(1)(ii)

  • (1) Use fabric filter collection devices, except as noted in paragraph (b) of this section, doing all of the following:
    (i) Ensuring that the airflow permeability, as determined by ASTM Method D737-75, does not exceed 9 m 3/min/m 2 (30 ft 3/min/ft 2) for woven fabrics or 11 3/min/m 2(35 ft 3/min/ft 2) for felted fabrics, except that 12 m 3/min/m 2 (40 ft 3min/ft 2) for woven and 14 m 3/min/m 2 (45 ft 3min/ft 2) for felted fabrics is allowed for filtering air from asbestos ore dryers; and
    (ii) Ensuring that felted fabric weighs at least 475 grams per square meter (14 ounces per square yard) and is at least 1.6 millimeters (one-sixteenth inch) thick throughout; and
    (2) Bypass devices may be used only during upset or emergency conditions and then only for so long as it takes to shut down the operation generating the particulate asbestos material.
    (3) For fabric filter collection devices installed after January 10, 1989, provide for easy inspection for faulty bags.

Citations to §61.149(c)(2)

Citations to §61.149(d)(1)

Citations to §61.149(d)(1)(i)

Citations to §61.149(d)(1)(ii)

Citations to §61.149(d)(1)(iii)

Citations to §61.149(ii)

Citations to §61.149(iii)