  • (c) The owner or operator shall determine compliance with the particulate matter standard in § 60.682 as follows:
    (1) The emission rate (E) of particulate matter shall be computed for each run using the following equation:
    (2) Method 5E shall be used to determine the particulate matter concentration (Ct) and the volumetric flow rate (Qsd) of the effluent gas. The sampling time and sample volume shall be at least 120 minutes and 2.55 dscm (90.1 dscf).
    (3) The average glass pull rate (Pavg) for the manufacturing line shall be the arithmetic average of three glass pull rate (Pi) determinations taken at intervals of at least 30 minutes during each run.
    (i) see § 60.17), shall be used to determine the LOI for each run.
    (ii) Line speed (Ls), trimmed mat width (Wm), and mat gram weight (M) shall be determined for each run from the process information or from direct measurements.