§60.622. Standards for volatile organic compounds.
40 C.F.R. § 60.622
Each affected petroleum solvent dry cleaning dryer that is installed at a petroleum dry cleaning plant after December 14, 1982, shall be a solvent recovery dryer. The solvent recovery dryer(s) shall be properly installed, operated, and maintained.
Each affected petroleum solvent filter that is installed at a petroleum dry cleaning plant after December 14, 1982, shall be a cartridge filter. Cartridge filters shall be drained in their sealed housings for at least 8 hours prior to their removal
Each manufacturer of an affected petroleum solvent dryer shall include leak inspection and leak repair cycle information in the operating manual and on a clearly visible label posted on each affected facility. Such information should state:
Notes, amendments, and revision history
Amendments
[49 FR 37331, Sept. 21, 1984, as amended at 50 FR 49026, Nov. 27, 1985]
Source
Source: 49 FR 37331, Sept. 21, 1984, unless otherwise noted.
Authority
Authority: 42 U.S.C. 7401 et seq.
Source
Source: 36 FR 24877, Dec. 23, 1971, unless otherwise noted.
Amendments
[49 FR 37331, Sept. 21, 1984, as amended at 50 FR 49026, Nov. 27, 1985]