§60.494. Monitoring of emissions and operations. — Inbound Citations
40 C.F.R. § 60.494
Statutory Authority
Cited by 1 regulation in release Current.
Citations to 40 U.S.C. § 60.494 as a whole
-
(2) Where compliance with § 60.492 is achieved through the use of catalytic incineration, each 3-hour period when cans are being processed, during which the average temperature of the device immediately before the catalyst bed is more than 28 °C below the average temperature of the device immediately before the catalyst bed during the most recent performance test at which destruction efficiency was determined as specified under § 60.493 and all 3-hour periods, when cans are being processed, during which the average temperature difference across the catalyst bed is less than 80 percent of the average temperature difference across the catalyst bed during the most recent performance test at which destruction efficiency was determined as specified under § 60.494.