§60.45Da. Alternative standards for combined nitrogen oxides (NO X ) and carbon monoxide (CO). — Inbound Citations
40 C.F.R. § 60.45Da
Statutory Authority
Cited by 5 regulations in release Current.
Citations to 40 C.F.R. § 60.45Da as a whole
-
(g) Except as provided in paragraphs (h) of this section and § 60.45Da, on and after the date on which the initial performance test is completed or required to be completed under § 60.8, whichever date comes first, no owner or operator of an affected facility that commenced construction, reconstruction, or modification after May 3, 2011, shall cause to be discharged into the atmosphere from that affected facility any gases that contain NOX (expressed as NO2) in excess of the applicable emissions limit specified in paragraphs (g)(1) through (3) of this section.(1) For an affected facility which commenced construction or reconstruction, any gases that contain NOX in excess of either:(i) 88 ng/J (0.70 lb/MWh) gross energy output; or(ii) 95 ng/J (0.76 lb/MWh) net energy output.(2) For an affected facility which commenced construction or reconstruction and that burns 75 percent or more coal refuse (by heat input) on a 12-month rolling average basis, any gases that contain NOX in excess of either:(i) 110 ng/J (0.85 lb/MWh) gross energy output; or(ii) 120 ng/J (0.92 lb/MWh) net energy output.(3) For an affected facility which commenced modification, any gases that contain NOX in excess of 140 ng/J (1.1 lb/MWh) gross energy output.
-
(a) For affected facilities for which construction, modification, or reconstruction commenced before May 4, 2011, the applicable PM emissions limit and opacity standard under § 60.42Da, SO2 emissions limit under § 60.43Da, and NOX emissions limit under § 60.44Da apply at all times except during periods of startup, shutdown, or malfunction. For affected facilities for which construction, modification, or reconstruction commenced after May 3, 2011, the applicable SO2 emissions limit under § 60.43Da, NOX emissions limit under § 60.44Da, and NOX plus CO emissions limit under § 60.45Da apply at all times. The applicable PM emissions limit and opacity standard under § 60.42Da apply at all times except during periods of startup and shutdown.
Citations to §60.45Da(b)(1)
-
(b) On and after the date on which the initial performance test is completed or required to be completed under § 60.8 no owner or operator of an affected facility that commenced construction, reconstruction, or modification after May 3, 2011, shall cause to be discharged into the atmosphere from that affected facility any gases that contain NOX (expressed as NO2) plus CO in excess of the applicable emissions limit specified in paragraphs (b)(1) through (3) of this section as determined on a 30-boiler operating day rolling average basis.(1) For an affected facility which commenced construction or reconstruction, any gases that contain NOX plus CO in excess of either:(i) 140 ng/J (1.1 lb/MWh) gross energy output; or(ii) 150 ng/J (1.2 lb/MWh) net energy output.(2) For an affected facility which commenced construction or reconstruction and that burns 75 percent or more coal refuse (by heat input) on a 12-month rolling average basis, any gases that contain NOX plus CO in excess of either:(i) 160 ng/J (1.3 lb/MWh) gross energy output; or(ii) 170 ng/J (1.4 lb/MWh) net energy output.(3) For an affected facility which commenced modification, any gases that contain NOX plus CO in excess of 190 ng/J (1.5 lb/MWh) gross energy output.
Citations to §60.45Da(b)(2)
-
(b) On and after the date on which the initial performance test is completed or required to be completed under § 60.8 no owner or operator of an affected facility that commenced construction, reconstruction, or modification after May 3, 2011, shall cause to be discharged into the atmosphere from that affected facility any gases that contain NOX (expressed as NO2) plus CO in excess of the applicable emissions limit specified in paragraphs (b)(1) through (3) of this section as determined on a 30-boiler operating day rolling average basis.(1) For an affected facility which commenced construction or reconstruction, any gases that contain NOX plus CO in excess of either:(i) 140 ng/J (1.1 lb/MWh) gross energy output; or(ii) 150 ng/J (1.2 lb/MWh) net energy output.(2) For an affected facility which commenced construction or reconstruction and that burns 75 percent or more coal refuse (by heat input) on a 12-month rolling average basis, any gases that contain NOX plus CO in excess of either:(i) 160 ng/J (1.3 lb/MWh) gross energy output; or(ii) 170 ng/J (1.4 lb/MWh) net energy output.(3) For an affected facility which commenced modification, any gases that contain NOX plus CO in excess of 190 ng/J (1.5 lb/MWh) gross energy output.
Citations to §60.45Da(b)(3)
-
(b) On and after the date on which the initial performance test is completed or required to be completed under § 60.8 no owner or operator of an affected facility that commenced construction, reconstruction, or modification after May 3, 2011, shall cause to be discharged into the atmosphere from that affected facility any gases that contain NOX (expressed as NO2) plus CO in excess of the applicable emissions limit specified in paragraphs (b)(1) through (3) of this section as determined on a 30-boiler operating day rolling average basis.(1) For an affected facility which commenced construction or reconstruction, any gases that contain NOX plus CO in excess of either:(i) 140 ng/J (1.1 lb/MWh) gross energy output; or(ii) 150 ng/J (1.2 lb/MWh) net energy output.(2) For an affected facility which commenced construction or reconstruction and that burns 75 percent or more coal refuse (by heat input) on a 12-month rolling average basis, any gases that contain NOX plus CO in excess of either:(i) 160 ng/J (1.3 lb/MWh) gross energy output; or(ii) 170 ng/J (1.4 lb/MWh) net energy output.(3) For an affected facility which commenced modification, any gases that contain NOX plus CO in excess of 190 ng/J (1.5 lb/MWh) gross energy output.