§60.293. Standards for particulate matter from glass melting furnace with modified-processes. — Inbound Citations
40 C.F.R. § 60.293
Statutory Authority
Cited by 2 regulations in release Current.
Citations to 40 C.F.R. § 60.293 as a whole
-
(d) The owner or operator shall determine compliance with the particulate matter standards in §§ 60.292 and 60.293 as follows:(1) The emission rate (E) of particulate matter shall be computed for each run using the following equation:(2) Method 5 shall be used to determine the particulate matter concentration (cs) and volumetric flow rate (Qsd) of the effluent gas. The sampling time and sample volume for each run shall be at least 60 minutes and 0.90 dscm (31.8 dscf). The probe and filter holder heating system may be set to provide a gas temperature no greater than 177 ±14 °C (350 ±25 °F), except under the conditions specified in § 60.293(e).(3) Direct measurement or material balance using good engineering practice shall be used to determine the amount of glass pulled during the performance test. The rate of glass produced is defined as the weight of glass pulled from the affected facility during the performance test divided by the number of hours taken to perform the performance test.(4) Method 9 and the procedures in § 60.11 shall be used to determine opacity.
Citations to §60.293(e)
-
(2) Method 5 shall be used to determine the particulate matter concentration (cs) and volumetric flow rate (Qsd) of the effluent gas. The sampling time and sample volume for each run shall be at least 60 minutes and 0.90 dscm (31.8 dscf). The probe and filter holder heating system may be set to provide a gas temperature no greater than 177 ±14 °C (350 ±25 °F), except under the conditions specified in § 60.293(e).