§60.272. Standard for particulate matter. — Inbound Citations

40 C.F.R. § 60.272

Cited by 11 regulations in release Current.

Citations to 40 U.S.C. § 60.272 as a whole

  • (e) The owner or operator shall determine compliance with the particulate matter standards in § 60.272 as follows:
    (1) EPA Method 5 (and referenced EPA Methods 1, 2, 3, 3A, 3B, and 4) shall be used for negative-pressure fabric filters and other types of control devices and EPA Method 5D (and referenced EPA Method 5) shall be used for positive-pressure fabric filters to determine the particulate matter concentration and, if applicable, the volumetric flow rate of the effluent gas. The sampling time and sample volume for each run shall be at least 4 hours and 4.5 dscm (160 dscf) and, when a single EAF is sampled, the sampling time shall include an integral number of heats. The manual portions only and not the instrumental portion of the voluntary consensus standard ANSI/ASME PTC 19.10-1981 (incorporated by reference, see § 60.17) is an acceptable alternative to EPA Methods 3, 3A, and 3B.
    (2) When more than one control device serves the EAF(s) being tested, the concentration of particulate matter shall be determined using the following equation:
    (3) EPA Method 9 or, as an alternative, ASTM D7520-16 (incorporated by reference, see § 60.17), with the caveats described under Shop opacity in § 60.271, and the procedures of § 60.11 shall be used to determine opacity.
    (4) To demonstrate compliance with § 60.272(a)(1), (2), and (3), the EPA Method 9 test runs shall be conducted concurrently with the particulate matter test runs, unless inclement weather interferes.

Citations to §60.272(a)

  • (h) If visible emissions observations are made in lieu of using a continuous opacity monitoring system, as allowed for by § 60.273(c), visible emission observations shall be conducted at least once per day for at least three 6-minute periods when the furnace is operating in the melting and refining period. All visible emissions observations shall be conducted in accordance with EPA Method 9. If visible emissions occur from more than one point, the opacity shall be recorded for any points where visible emissions are observed. Where it is possible to determine that a number of visible emission sites relate to only one incident of the visible emission, only one set of three 6-minute observations will be required. In that case, the EPA Method 9 observations must be made for the site of highest opacity that directly relates to the cause (or location) of visible emissions observed during a single incident. Records shall be maintained of any 6-minute average that is in excess of the emission limit specified in § 60.272(a).
  • (c) For the purpose of this subpart, the owner or operator shall conduct the demonstration of compliance with § 60.272(a) of this subpart and furnish the Administrator or delegated authority with a written report of the results of the test. This report shall include the following information:
    (1) Facility name and address;
    (2) Plant representative;
    (3) Make and model of the control device, and continuous opacity monitoring equipment, if applicable;
    (4) Flow diagram of process and emission capture system including other equipment or process(es) ducted to the same control device;
    (5) Rated (design) capacity of process equipment;
    (6) Those data required under § 60.274(i) of this subpart;
    (i) List of charge and tap weights and materials;
    (ii) Heat times and process log;
    (iii) Control device operation log; and
    (iv) Continuous opacity monitor or EPA Method 9 data, or, as an alternative to EPA Method 9, according to ASTM D7520-16 (incorporated by reference, see § 60.17), with the caveats described under Shop opacity in § 60.271.
    (7) Test dates and test times;
    (8) Test company;
    (9) Test company representative;
    (10) Test observers from any outside agency;
    (11) Description of test methodology used, including any deviation from standard reference methods
    (12) Schematic of sampling location;
    (13) Number of sampling points;
    (14) Description of sampling equipment;
    (15) Listing of sampling equipment calibrations and procedures;
    (16) Field and laboratory data sheets;
    (17) Description of sample recovery procedures;
    (18) Sampling equipment leak check results;
    (19) Description of quality assurance procedures;
    (20) Description of analytical procedures;
    (21) Notation of sample blank corrections; and

Citations to §60.272(a)(1)

Citations to §60.272(a)(2)

  • (3) If visible emissions occur from more than one point, the opacity shall be recorded for any points where visible emissions are observed. Where it is possible to determine that a number of visible emission points relate to only one incident of the visible emission, only one set of three 6-minute observations will be required. In that case, EPA Method 9 observations must be made for the point of highest opacity that directly relates to the cause (or location) of visible emissions observed during a single incident. Records shall be maintained of any 6-minute average that is in excess of the emission limit specified in § 60.272(a)(2).
  • (3) If visible emissions occur from more than one point, the opacity shall be recorded for any points where visible emissions are observed. Where it is possible to determine that a number of visible emission points relate to only one incident of the visible emission, only one set of three 6-minute observations will be required. In that case, EPA Method 9 observations must be made for the point of highest opacity that directly relates to the cause (or location) of visible emissions observed during a single incident. Records shall be maintained of any 6-minute average that is in excess of the emission limit specified in § 60.272(a)(2).
  • (4) To demonstrate compliance with § 60.272(a)(1), (2), and (3), the EPA Method 9 test runs shall be conducted concurrently with the particulate matter test runs, unless inclement weather interferes.

Citations to §60.272(a)(3)

  • (m) Shop means the building that houses one or more EAF's and serves as the point from which compliance with § 60.272(a)(3), “Standard for Particulate Matter,” is measured.
  • (1) When the owner or operator of an affected facility is required to demonstrate compliance with the standards under § 60.272(a)(3) and at any other time that the Administrator may require (under section 114 of the CAA, as amended), the owner or operator shall, during periods in which a hood is operated for the purpose of capturing emissions from the affected facility subject to paragraph (b) of this section, either:
    (i) Monitor and record the fan motor amperes at each damper position, and damper position consistent with paragraph (i)(5) of this section; or
    (ii) Monitor and record as no greater than 15-minute integrated block average basis the volumetric flow rate through each separately ducted hood; or
    (iii) Install, calibrate, and maintain a monitoring device that continuously records the volumetric flow rate at the control device inlet and monitor and record the damper position consistent with paragraph (i)(5) of this section.
  • (c) When emissions from any EAF(s) are combined with emissions from facilities not subject to the provisions of this subpart, compliance with § 60.272(a)(3) will be based on emissions from only the affected facility(ies). The owner or operator may use operational knowledge to determine the facilities that are the sources, in whole or in part, of any emissions observed in demonstrations of compliance with § 60.272(a)(3).
  • (d) The owner or operator shall maintain records of all shop opacity observations made in accordance with § 60.273(d). All shop opacity observations in excess of the emission limit specified in § 60.272(a)(3) of this subpart shall indicate a period of excess emissions, and shall be reported to the Administrator or delegated authority semi-annually, according to § 60.7(c) and submitted according to paragraph (h) of this section. In addition to the information required at § 60.7(c), the report shall include the following information:
    (4) This certification shall state that, based on information and belief formed after reasonable inquiry, the statements and information in the document are true, accurate, and complete.