§60.172. Standard for particulate matter. — Inbound Citations

40 C.F.R. § 60.172

Cited by 4 regulations in release Current.

Citations to 40 U.S.C. § 60.172 as a whole

  • (b) The owner or operator shall determine compliance with the particulate matter, sulfur dioxide (SO2), and visible emission standards in §§ 60.172, 60.173, and 60.174 as follows:
    (1) Method 5 shall be used to determine the particulate matter concentration. The sampling time and sample volume for each run shall be at least 60 minutes and 0.85 dscm (30 dscf).
    (2) The continuous monitoring system of § 60.175(a)(2) shall be used to determine the SO2 concentrations on a dry basis. The sampling time for each run shall be 2 hours, and the average SO2 concentration for the 2-hour period shall be computed as in § 60.175(b). The monitoring system drift during the run may not exceed 2 percent of the span value.
    (3) Method 9 and the procedures in § 60.11 shall be used to determine opacity.

Citations to §60.172(a)

Citations to §60.172(b)(2)(ii)(B)