§60.165. Monitoring of operations. — Inbound Citations

40 C.F.R. § 60.165

Cited by 2 regulations in release Current.

Citations to §60.165(b)(2)

  • (2) The continuous monitoring system of § 60.165(b)(2) shall be used to determine the SO2 concentrations on a dry basis. The sampling time for each run shall be 6 hours, and the average SO2 concentration shall be computed for the 6-hour period as in § 60.165(c). The monitoring system drift during the run may not exceed 2 percent of the span value.

Citations to §60.165(c)

  • (2) The continuous monitoring system of § 60.165(b)(2) shall be used to determine the SO2 concentrations on a dry basis. The sampling time for each run shall be 6 hours, and the average SO2 concentration shall be computed for the 6-hour period as in § 60.165(c). The monitoring system drift during the run may not exceed 2 percent of the span value.