§60.124. Monitoring requirements. — Inbound Citations
40 C.F.R. § 60.124
Statutory Authority
Cited by 44 regulations in release Current.
Citations to §60.124(a)
-
(l) If an affected source is subject to the monitoring requirements specified in 40 CFR part 63, subpart X (National Emissions Standards for Hazardous Air Pollutants from Secondary Lead Smelting) and those requirements are as stringent or more stringent than the monitoring requirements specified in paragraphs (a) through (j) of this section, compliance with the monitoring requirements specified in 40 CFR part 63, subpart X also demonstrates compliance with the monitoring requirements specified in paragraphs (a) through (k) of this section.
Citations to §60.124(b)
-
(l) If an affected source is subject to the monitoring requirements specified in 40 CFR part 63, subpart X (National Emissions Standards for Hazardous Air Pollutants from Secondary Lead Smelting) and those requirements are as stringent or more stringent than the monitoring requirements specified in paragraphs (a) through (j) of this section, compliance with the monitoring requirements specified in 40 CFR part 63, subpart X also demonstrates compliance with the monitoring requirements specified in paragraphs (a) through (k) of this section.
-
(b) The SOP manual required in § 60.124(b) shall be submitted to the Administrator in electronic format for review and approval of the initial submittal and whenever an update is made to the procedure.
Citations to §60.124(c)
-
(l) If an affected source is subject to the monitoring requirements specified in 40 CFR part 63, subpart X (National Emissions Standards for Hazardous Air Pollutants from Secondary Lead Smelting) and those requirements are as stringent or more stringent than the monitoring requirements specified in paragraphs (a) through (j) of this section, compliance with the monitoring requirements specified in 40 CFR part 63, subpart X also demonstrates compliance with the monitoring requirements specified in paragraphs (a) through (k) of this section.
Citations to §60.124(d)
-
(l) If an affected source is subject to the monitoring requirements specified in 40 CFR part 63, subpart X (National Emissions Standards for Hazardous Air Pollutants from Secondary Lead Smelting) and those requirements are as stringent or more stringent than the monitoring requirements specified in paragraphs (a) through (j) of this section, compliance with the monitoring requirements specified in 40 CFR part 63, subpart X also demonstrates compliance with the monitoring requirements specified in paragraphs (a) through (k) of this section.
-
(3) All records of inspections and maintenance activities required under § 60.124(d) as part of the practices described in the SOP manual for baghouses required under § 60.124(b).
Citations to §60.124(d)(1)
-
(d) The procedures specified in the SOP manual for inspections and routine maintenance shall, at a minimum, include the requirements of paragraphs (d)(1) through (9) of this section.(2) Weekly confirmation that dust is being removed from hoppers through visual inspection, or equivalent means of ensuring the proper functioning of removal mechanisms.(5) Monthly check of bag cleaning mechanisms for proper functioning through visual inspection or equivalent means.(6) Such checks are not required for shaker-type baghouses using self-tensioning (spring loaded) devices.(7) Quarterly confirmation of the physical integrity of the baghouse through visual inspection of the baghouse interior for air leaks.(8) Quarterly inspection of fans for wear, material buildup, and corrosion through visual inspection, vibration detectors, or equivalent means.
Citations to §60.124(d)(2)
-
(d) The procedures specified in the SOP manual for inspections and routine maintenance shall, at a minimum, include the requirements of paragraphs (d)(1) through (9) of this section.(2) Weekly confirmation that dust is being removed from hoppers through visual inspection, or equivalent means of ensuring the proper functioning of removal mechanisms.(5) Monthly check of bag cleaning mechanisms for proper functioning through visual inspection or equivalent means.(6) Such checks are not required for shaker-type baghouses using self-tensioning (spring loaded) devices.(7) Quarterly confirmation of the physical integrity of the baghouse through visual inspection of the baghouse interior for air leaks.(8) Quarterly inspection of fans for wear, material buildup, and corrosion through visual inspection, vibration detectors, or equivalent means.
Citations to §60.124(d)(3)
-
(d) The procedures specified in the SOP manual for inspections and routine maintenance shall, at a minimum, include the requirements of paragraphs (d)(1) through (9) of this section.(2) Weekly confirmation that dust is being removed from hoppers through visual inspection, or equivalent means of ensuring the proper functioning of removal mechanisms.(5) Monthly check of bag cleaning mechanisms for proper functioning through visual inspection or equivalent means.(6) Such checks are not required for shaker-type baghouses using self-tensioning (spring loaded) devices.(7) Quarterly confirmation of the physical integrity of the baghouse through visual inspection of the baghouse interior for air leaks.(8) Quarterly inspection of fans for wear, material buildup, and corrosion through visual inspection, vibration detectors, or equivalent means.
Citations to §60.124(d)(4)
-
(d) The procedures specified in the SOP manual for inspections and routine maintenance shall, at a minimum, include the requirements of paragraphs (d)(1) through (9) of this section.(2) Weekly confirmation that dust is being removed from hoppers through visual inspection, or equivalent means of ensuring the proper functioning of removal mechanisms.(5) Monthly check of bag cleaning mechanisms for proper functioning through visual inspection or equivalent means.(6) Such checks are not required for shaker-type baghouses using self-tensioning (spring loaded) devices.(7) Quarterly confirmation of the physical integrity of the baghouse through visual inspection of the baghouse interior for air leaks.(8) Quarterly inspection of fans for wear, material buildup, and corrosion through visual inspection, vibration detectors, or equivalent means.
Citations to §60.124(d)(5)
-
(d) The procedures specified in the SOP manual for inspections and routine maintenance shall, at a minimum, include the requirements of paragraphs (d)(1) through (9) of this section.(2) Weekly confirmation that dust is being removed from hoppers through visual inspection, or equivalent means of ensuring the proper functioning of removal mechanisms.(5) Monthly check of bag cleaning mechanisms for proper functioning through visual inspection or equivalent means.(6) Such checks are not required for shaker-type baghouses using self-tensioning (spring loaded) devices.(7) Quarterly confirmation of the physical integrity of the baghouse through visual inspection of the baghouse interior for air leaks.(8) Quarterly inspection of fans for wear, material buildup, and corrosion through visual inspection, vibration detectors, or equivalent means.
Citations to §60.124(d)(6)
-
(d) The procedures specified in the SOP manual for inspections and routine maintenance shall, at a minimum, include the requirements of paragraphs (d)(1) through (9) of this section.(2) Weekly confirmation that dust is being removed from hoppers through visual inspection, or equivalent means of ensuring the proper functioning of removal mechanisms.(5) Monthly check of bag cleaning mechanisms for proper functioning through visual inspection or equivalent means.(6) Such checks are not required for shaker-type baghouses using self-tensioning (spring loaded) devices.(7) Quarterly confirmation of the physical integrity of the baghouse through visual inspection of the baghouse interior for air leaks.(8) Quarterly inspection of fans for wear, material buildup, and corrosion through visual inspection, vibration detectors, or equivalent means.
Citations to §60.124(d)(7)
-
(d) The procedures specified in the SOP manual for inspections and routine maintenance shall, at a minimum, include the requirements of paragraphs (d)(1) through (9) of this section.(2) Weekly confirmation that dust is being removed from hoppers through visual inspection, or equivalent means of ensuring the proper functioning of removal mechanisms.(5) Monthly check of bag cleaning mechanisms for proper functioning through visual inspection or equivalent means.(6) Such checks are not required for shaker-type baghouses using self-tensioning (spring loaded) devices.(7) Quarterly confirmation of the physical integrity of the baghouse through visual inspection of the baghouse interior for air leaks.(8) Quarterly inspection of fans for wear, material buildup, and corrosion through visual inspection, vibration detectors, or equivalent means.
Citations to §60.124(d)(8)
-
(d) The procedures specified in the SOP manual for inspections and routine maintenance shall, at a minimum, include the requirements of paragraphs (d)(1) through (9) of this section.(2) Weekly confirmation that dust is being removed from hoppers through visual inspection, or equivalent means of ensuring the proper functioning of removal mechanisms.(5) Monthly check of bag cleaning mechanisms for proper functioning through visual inspection or equivalent means.(6) Such checks are not required for shaker-type baghouses using self-tensioning (spring loaded) devices.(7) Quarterly confirmation of the physical integrity of the baghouse through visual inspection of the baghouse interior for air leaks.(8) Quarterly inspection of fans for wear, material buildup, and corrosion through visual inspection, vibration detectors, or equivalent means.
Citations to §60.124(d)(9)
-
(d) The procedures specified in the SOP manual for inspections and routine maintenance shall, at a minimum, include the requirements of paragraphs (d)(1) through (9) of this section.(2) Weekly confirmation that dust is being removed from hoppers through visual inspection, or equivalent means of ensuring the proper functioning of removal mechanisms.(5) Monthly check of bag cleaning mechanisms for proper functioning through visual inspection or equivalent means.(6) Such checks are not required for shaker-type baghouses using self-tensioning (spring loaded) devices.(7) Quarterly confirmation of the physical integrity of the baghouse through visual inspection of the baghouse interior for air leaks.(8) Quarterly inspection of fans for wear, material buildup, and corrosion through visual inspection, vibration detectors, or equivalent means.
-
(7) Records of all alarms from the bag leak detection system specified in § 60.124(d)(9).
Citations to §60.124(e)
-
(l) If an affected source is subject to the monitoring requirements specified in 40 CFR part 63, subpart X (National Emissions Standards for Hazardous Air Pollutants from Secondary Lead Smelting) and those requirements are as stringent or more stringent than the monitoring requirements specified in paragraphs (a) through (j) of this section, compliance with the monitoring requirements specified in 40 CFR part 63, subpart X also demonstrates compliance with the monitoring requirements specified in paragraphs (a) through (k) of this section.
Citations to §60.124(f)
-
(l) If an affected source is subject to the monitoring requirements specified in 40 CFR part 63, subpart X (National Emissions Standards for Hazardous Air Pollutants from Secondary Lead Smelting) and those requirements are as stringent or more stringent than the monitoring requirements specified in paragraphs (a) through (j) of this section, compliance with the monitoring requirements specified in 40 CFR part 63, subpart X also demonstrates compliance with the monitoring requirements specified in paragraphs (a) through (k) of this section.
-
(3) EPA-454/R-98-015, Office of Air Quality Planning and Standards (OAQPS), Fabric Filter Bag Leak Detection Guidance, September 1997; IBR approved for §§ 60.124(f); 60.124a(f); 60.273(e); 60.273a(e); 60.273b(e); 60.373a(b); 60.2145(r); 60.2710(r); 60.2944(c), 60.3043(c), 60.4880(b); 60.5200(b). (Available from: https://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=2000D5T6.pdf).
Citations to §60.124(f)(1)
-
(f) The bag leak detection system required by paragraph (d)(9) of this section, shall meet the specification and requirements of paragraphs (f)(1) through (8) of this section.(1) The bag leak detection system shall be certified by the manufacturer to be capable of detecting PM emissions at concentrations of 50.0 mg/dscm (0.022 gr/dscf) or less.(2) The bag leak detection system sensor shall provide output of relative PM loadings.(3) The bag leak detection system shall be equipped with an alarm system that will alarm when an increase in relative particulate loadings is detected over a preset level.(4) The owner shall install and operate the bag leak detection system in a manner consistent with the guidance provided in EPA-454/R-98-015, Office of Air quality Planning and Standards (OAQPS) Fabric Filter Bag Leak Detection Guidance, (incorporated by reference, see § 60.17) or the manufacturer's written specifications and recommendations for installation, operation, and adjustment of the system.(5) The initial adjustment of the system shall, at a minimum, consist of establishing the baseline output by adjusting the sensitivity (range) and the averaging period of the device, and establishing the alarm set points and the alarm delay time.(6) Following initial adjustment, the owner shall not adjust the sensitivity or range, averaging period, alarm set points, or alarm delay time, except as detailed in the approved SOP manual required under paragraph (b) of this section. The owner cannot increase the sensitivity by more than 100 percent or decrease the sensitivity by more than 50 percent over a 365-day period unless such adjustment follows a complete baghouse inspection that demonstrates that the baghouse is in good operating condition.(7) For negative pressure, induced air baghouses, and positive pressure baghouses that are discharged to the atmosphere through a stack, the owner shall install the bag leak detector downstream of the baghouse and upstream of any wet acid gas scrubber.(8) Where multiple detectors are required, the system's instrumentation and alarm may be shared among detectors.
Citations to §60.124(f)(2)
-
(f) The bag leak detection system required by paragraph (d)(9) of this section, shall meet the specification and requirements of paragraphs (f)(1) through (8) of this section.(1) The bag leak detection system shall be certified by the manufacturer to be capable of detecting PM emissions at concentrations of 50.0 mg/dscm (0.022 gr/dscf) or less.(2) The bag leak detection system sensor shall provide output of relative PM loadings.(3) The bag leak detection system shall be equipped with an alarm system that will alarm when an increase in relative particulate loadings is detected over a preset level.(4) The owner shall install and operate the bag leak detection system in a manner consistent with the guidance provided in EPA-454/R-98-015, Office of Air quality Planning and Standards (OAQPS) Fabric Filter Bag Leak Detection Guidance, (incorporated by reference, see § 60.17) or the manufacturer's written specifications and recommendations for installation, operation, and adjustment of the system.(5) The initial adjustment of the system shall, at a minimum, consist of establishing the baseline output by adjusting the sensitivity (range) and the averaging period of the device, and establishing the alarm set points and the alarm delay time.(6) Following initial adjustment, the owner shall not adjust the sensitivity or range, averaging period, alarm set points, or alarm delay time, except as detailed in the approved SOP manual required under paragraph (b) of this section. The owner cannot increase the sensitivity by more than 100 percent or decrease the sensitivity by more than 50 percent over a 365-day period unless such adjustment follows a complete baghouse inspection that demonstrates that the baghouse is in good operating condition.(7) For negative pressure, induced air baghouses, and positive pressure baghouses that are discharged to the atmosphere through a stack, the owner shall install the bag leak detector downstream of the baghouse and upstream of any wet acid gas scrubber.(8) Where multiple detectors are required, the system's instrumentation and alarm may be shared among detectors.
Citations to §60.124(f)(3)
-
(f) The bag leak detection system required by paragraph (d)(9) of this section, shall meet the specification and requirements of paragraphs (f)(1) through (8) of this section.(1) The bag leak detection system shall be certified by the manufacturer to be capable of detecting PM emissions at concentrations of 50.0 mg/dscm (0.022 gr/dscf) or less.(2) The bag leak detection system sensor shall provide output of relative PM loadings.(3) The bag leak detection system shall be equipped with an alarm system that will alarm when an increase in relative particulate loadings is detected over a preset level.(4) The owner shall install and operate the bag leak detection system in a manner consistent with the guidance provided in EPA-454/R-98-015, Office of Air quality Planning and Standards (OAQPS) Fabric Filter Bag Leak Detection Guidance, (incorporated by reference, see § 60.17) or the manufacturer's written specifications and recommendations for installation, operation, and adjustment of the system.(5) The initial adjustment of the system shall, at a minimum, consist of establishing the baseline output by adjusting the sensitivity (range) and the averaging period of the device, and establishing the alarm set points and the alarm delay time.(6) Following initial adjustment, the owner shall not adjust the sensitivity or range, averaging period, alarm set points, or alarm delay time, except as detailed in the approved SOP manual required under paragraph (b) of this section. The owner cannot increase the sensitivity by more than 100 percent or decrease the sensitivity by more than 50 percent over a 365-day period unless such adjustment follows a complete baghouse inspection that demonstrates that the baghouse is in good operating condition.(7) For negative pressure, induced air baghouses, and positive pressure baghouses that are discharged to the atmosphere through a stack, the owner shall install the bag leak detector downstream of the baghouse and upstream of any wet acid gas scrubber.(8) Where multiple detectors are required, the system's instrumentation and alarm may be shared among detectors.
Citations to §60.124(f)(4)
-
(f) The bag leak detection system required by paragraph (d)(9) of this section, shall meet the specification and requirements of paragraphs (f)(1) through (8) of this section.(1) The bag leak detection system shall be certified by the manufacturer to be capable of detecting PM emissions at concentrations of 50.0 mg/dscm (0.022 gr/dscf) or less.(2) The bag leak detection system sensor shall provide output of relative PM loadings.(3) The bag leak detection system shall be equipped with an alarm system that will alarm when an increase in relative particulate loadings is detected over a preset level.(4) The owner shall install and operate the bag leak detection system in a manner consistent with the guidance provided in EPA-454/R-98-015, Office of Air quality Planning and Standards (OAQPS) Fabric Filter Bag Leak Detection Guidance, (incorporated by reference, see § 60.17) or the manufacturer's written specifications and recommendations for installation, operation, and adjustment of the system.(5) The initial adjustment of the system shall, at a minimum, consist of establishing the baseline output by adjusting the sensitivity (range) and the averaging period of the device, and establishing the alarm set points and the alarm delay time.(6) Following initial adjustment, the owner shall not adjust the sensitivity or range, averaging period, alarm set points, or alarm delay time, except as detailed in the approved SOP manual required under paragraph (b) of this section. The owner cannot increase the sensitivity by more than 100 percent or decrease the sensitivity by more than 50 percent over a 365-day period unless such adjustment follows a complete baghouse inspection that demonstrates that the baghouse is in good operating condition.(7) For negative pressure, induced air baghouses, and positive pressure baghouses that are discharged to the atmosphere through a stack, the owner shall install the bag leak detector downstream of the baghouse and upstream of any wet acid gas scrubber.(8) Where multiple detectors are required, the system's instrumentation and alarm may be shared among detectors.
Citations to §60.124(f)(5)
-
(f) The bag leak detection system required by paragraph (d)(9) of this section, shall meet the specification and requirements of paragraphs (f)(1) through (8) of this section.(1) The bag leak detection system shall be certified by the manufacturer to be capable of detecting PM emissions at concentrations of 50.0 mg/dscm (0.022 gr/dscf) or less.(2) The bag leak detection system sensor shall provide output of relative PM loadings.(3) The bag leak detection system shall be equipped with an alarm system that will alarm when an increase in relative particulate loadings is detected over a preset level.(4) The owner shall install and operate the bag leak detection system in a manner consistent with the guidance provided in EPA-454/R-98-015, Office of Air quality Planning and Standards (OAQPS) Fabric Filter Bag Leak Detection Guidance, (incorporated by reference, see § 60.17) or the manufacturer's written specifications and recommendations for installation, operation, and adjustment of the system.(5) The initial adjustment of the system shall, at a minimum, consist of establishing the baseline output by adjusting the sensitivity (range) and the averaging period of the device, and establishing the alarm set points and the alarm delay time.(6) Following initial adjustment, the owner shall not adjust the sensitivity or range, averaging period, alarm set points, or alarm delay time, except as detailed in the approved SOP manual required under paragraph (b) of this section. The owner cannot increase the sensitivity by more than 100 percent or decrease the sensitivity by more than 50 percent over a 365-day period unless such adjustment follows a complete baghouse inspection that demonstrates that the baghouse is in good operating condition.(7) For negative pressure, induced air baghouses, and positive pressure baghouses that are discharged to the atmosphere through a stack, the owner shall install the bag leak detector downstream of the baghouse and upstream of any wet acid gas scrubber.(8) Where multiple detectors are required, the system's instrumentation and alarm may be shared among detectors.
Citations to §60.124(f)(6)
-
(f) The bag leak detection system required by paragraph (d)(9) of this section, shall meet the specification and requirements of paragraphs (f)(1) through (8) of this section.(1) The bag leak detection system shall be certified by the manufacturer to be capable of detecting PM emissions at concentrations of 50.0 mg/dscm (0.022 gr/dscf) or less.(2) The bag leak detection system sensor shall provide output of relative PM loadings.(3) The bag leak detection system shall be equipped with an alarm system that will alarm when an increase in relative particulate loadings is detected over a preset level.(4) The owner shall install and operate the bag leak detection system in a manner consistent with the guidance provided in EPA-454/R-98-015, Office of Air quality Planning and Standards (OAQPS) Fabric Filter Bag Leak Detection Guidance, (incorporated by reference, see § 60.17) or the manufacturer's written specifications and recommendations for installation, operation, and adjustment of the system.(5) The initial adjustment of the system shall, at a minimum, consist of establishing the baseline output by adjusting the sensitivity (range) and the averaging period of the device, and establishing the alarm set points and the alarm delay time.(6) Following initial adjustment, the owner shall not adjust the sensitivity or range, averaging period, alarm set points, or alarm delay time, except as detailed in the approved SOP manual required under paragraph (b) of this section. The owner cannot increase the sensitivity by more than 100 percent or decrease the sensitivity by more than 50 percent over a 365-day period unless such adjustment follows a complete baghouse inspection that demonstrates that the baghouse is in good operating condition.(7) For negative pressure, induced air baghouses, and positive pressure baghouses that are discharged to the atmosphere through a stack, the owner shall install the bag leak detector downstream of the baghouse and upstream of any wet acid gas scrubber.(8) Where multiple detectors are required, the system's instrumentation and alarm may be shared among detectors.
Citations to §60.124(f)(7)
-
(f) The bag leak detection system required by paragraph (d)(9) of this section, shall meet the specification and requirements of paragraphs (f)(1) through (8) of this section.(1) The bag leak detection system shall be certified by the manufacturer to be capable of detecting PM emissions at concentrations of 50.0 mg/dscm (0.022 gr/dscf) or less.(2) The bag leak detection system sensor shall provide output of relative PM loadings.(3) The bag leak detection system shall be equipped with an alarm system that will alarm when an increase in relative particulate loadings is detected over a preset level.(4) The owner shall install and operate the bag leak detection system in a manner consistent with the guidance provided in EPA-454/R-98-015, Office of Air quality Planning and Standards (OAQPS) Fabric Filter Bag Leak Detection Guidance, (incorporated by reference, see § 60.17) or the manufacturer's written specifications and recommendations for installation, operation, and adjustment of the system.(5) The initial adjustment of the system shall, at a minimum, consist of establishing the baseline output by adjusting the sensitivity (range) and the averaging period of the device, and establishing the alarm set points and the alarm delay time.(6) Following initial adjustment, the owner shall not adjust the sensitivity or range, averaging period, alarm set points, or alarm delay time, except as detailed in the approved SOP manual required under paragraph (b) of this section. The owner cannot increase the sensitivity by more than 100 percent or decrease the sensitivity by more than 50 percent over a 365-day period unless such adjustment follows a complete baghouse inspection that demonstrates that the baghouse is in good operating condition.(7) For negative pressure, induced air baghouses, and positive pressure baghouses that are discharged to the atmosphere through a stack, the owner shall install the bag leak detector downstream of the baghouse and upstream of any wet acid gas scrubber.(8) Where multiple detectors are required, the system's instrumentation and alarm may be shared among detectors.
Citations to §60.124(f)(8)
-
(f) The bag leak detection system required by paragraph (d)(9) of this section, shall meet the specification and requirements of paragraphs (f)(1) through (8) of this section.(1) The bag leak detection system shall be certified by the manufacturer to be capable of detecting PM emissions at concentrations of 50.0 mg/dscm (0.022 gr/dscf) or less.(2) The bag leak detection system sensor shall provide output of relative PM loadings.(3) The bag leak detection system shall be equipped with an alarm system that will alarm when an increase in relative particulate loadings is detected over a preset level.(4) The owner shall install and operate the bag leak detection system in a manner consistent with the guidance provided in EPA-454/R-98-015, Office of Air quality Planning and Standards (OAQPS) Fabric Filter Bag Leak Detection Guidance, (incorporated by reference, see § 60.17) or the manufacturer's written specifications and recommendations for installation, operation, and adjustment of the system.(5) The initial adjustment of the system shall, at a minimum, consist of establishing the baseline output by adjusting the sensitivity (range) and the averaging period of the device, and establishing the alarm set points and the alarm delay time.(6) Following initial adjustment, the owner shall not adjust the sensitivity or range, averaging period, alarm set points, or alarm delay time, except as detailed in the approved SOP manual required under paragraph (b) of this section. The owner cannot increase the sensitivity by more than 100 percent or decrease the sensitivity by more than 50 percent over a 365-day period unless such adjustment follows a complete baghouse inspection that demonstrates that the baghouse is in good operating condition.(7) For negative pressure, induced air baghouses, and positive pressure baghouses that are discharged to the atmosphere through a stack, the owner shall install the bag leak detector downstream of the baghouse and upstream of any wet acid gas scrubber.(8) Where multiple detectors are required, the system's instrumentation and alarm may be shared among detectors.
Citations to §60.124(g)
-
(l) If an affected source is subject to the monitoring requirements specified in 40 CFR part 63, subpart X (National Emissions Standards for Hazardous Air Pollutants from Secondary Lead Smelting) and those requirements are as stringent or more stringent than the monitoring requirements specified in paragraphs (a) through (j) of this section, compliance with the monitoring requirements specified in 40 CFR part 63, subpart X also demonstrates compliance with the monitoring requirements specified in paragraphs (a) through (k) of this section.
Citations to §60.124(g)(2)(i)
-
(2) The cause of the alarm shall be alleviated by taking the necessary corrective action(s) that may include, but not be limited to, those listed in paragraphs (g)(2)(i) through (vi) of this section.(i) Inspecting the baghouse for air leaks, torn or broken filter elements, or any other malfunction that may cause an increase in emissions.
Citations to §60.124(g)(2)(ii)
-
(2) The cause of the alarm shall be alleviated by taking the necessary corrective action(s) that may include, but not be limited to, those listed in paragraphs (g)(2)(i) through (vi) of this section.(i) Inspecting the baghouse for air leaks, torn or broken filter elements, or any other malfunction that may cause an increase in emissions.
Citations to §60.124(g)(2)(iii)
-
(2) The cause of the alarm shall be alleviated by taking the necessary corrective action(s) that may include, but not be limited to, those listed in paragraphs (g)(2)(i) through (vi) of this section.(i) Inspecting the baghouse for air leaks, torn or broken filter elements, or any other malfunction that may cause an increase in emissions.
Citations to §60.124(g)(2)(iv)
-
(2) The cause of the alarm shall be alleviated by taking the necessary corrective action(s) that may include, but not be limited to, those listed in paragraphs (g)(2)(i) through (vi) of this section.(i) Inspecting the baghouse for air leaks, torn or broken filter elements, or any other malfunction that may cause an increase in emissions.
Citations to §60.124(g)(2)(v)
-
(2) The cause of the alarm shall be alleviated by taking the necessary corrective action(s) that may include, but not be limited to, those listed in paragraphs (g)(2)(i) through (vi) of this section.(i) Inspecting the baghouse for air leaks, torn or broken filter elements, or any other malfunction that may cause an increase in emissions.
Citations to §60.124(g)(2)(vi)
-
(2) The cause of the alarm shall be alleviated by taking the necessary corrective action(s) that may include, but not be limited to, those listed in paragraphs (g)(2)(i) through (vi) of this section.(i) Inspecting the baghouse for air leaks, torn or broken filter elements, or any other malfunction that may cause an increase in emissions.
Citations to §60.124(h)
-
(l) If an affected source is subject to the monitoring requirements specified in 40 CFR part 63, subpart X (National Emissions Standards for Hazardous Air Pollutants from Secondary Lead Smelting) and those requirements are as stringent or more stringent than the monitoring requirements specified in paragraphs (a) through (j) of this section, compliance with the monitoring requirements specified in 40 CFR part 63, subpart X also demonstrates compliance with the monitoring requirements specified in paragraphs (a) through (k) of this section.
Citations to §60.124(h)(1)
-
(h) Baghouses equipped with high-efficiency particulate air (HEPA) filters as a secondary filter used to control emissions from any source subject to the PM and opacity emission standards in § 60.122 are exempt from the requirement to be equipped with a bag leak detection system. The owner or operator shall monitor and record the pressure drop across each HEPA filter system daily. If the pressure drop is outside the limit(s) specified by the filter manufacturer, the owner or operator shall take appropriate corrective measures, which may include but not be limited to those given in paragraphs (h)(1) through (4) of this section.(3) Sealing off a defective control device by routing air to other control devices
Citations to §60.124(h)(2)
-
(h) Baghouses equipped with high-efficiency particulate air (HEPA) filters as a secondary filter used to control emissions from any source subject to the PM and opacity emission standards in § 60.122 are exempt from the requirement to be equipped with a bag leak detection system. The owner or operator shall monitor and record the pressure drop across each HEPA filter system daily. If the pressure drop is outside the limit(s) specified by the filter manufacturer, the owner or operator shall take appropriate corrective measures, which may include but not be limited to those given in paragraphs (h)(1) through (4) of this section.(3) Sealing off a defective control device by routing air to other control devices
Citations to §60.124(h)(3)
-
(h) Baghouses equipped with high-efficiency particulate air (HEPA) filters as a secondary filter used to control emissions from any source subject to the PM and opacity emission standards in § 60.122 are exempt from the requirement to be equipped with a bag leak detection system. The owner or operator shall monitor and record the pressure drop across each HEPA filter system daily. If the pressure drop is outside the limit(s) specified by the filter manufacturer, the owner or operator shall take appropriate corrective measures, which may include but not be limited to those given in paragraphs (h)(1) through (4) of this section.(3) Sealing off a defective control device by routing air to other control devices
Citations to §60.124(h)(4)
-
(h) Baghouses equipped with high-efficiency particulate air (HEPA) filters as a secondary filter used to control emissions from any source subject to the PM and opacity emission standards in § 60.122 are exempt from the requirement to be equipped with a bag leak detection system. The owner or operator shall monitor and record the pressure drop across each HEPA filter system daily. If the pressure drop is outside the limit(s) specified by the filter manufacturer, the owner or operator shall take appropriate corrective measures, which may include but not be limited to those given in paragraphs (h)(1) through (4) of this section.(3) Sealing off a defective control device by routing air to other control devices
Citations to §60.124(i)
-
(l) If an affected source is subject to the monitoring requirements specified in 40 CFR part 63, subpart X (National Emissions Standards for Hazardous Air Pollutants from Secondary Lead Smelting) and those requirements are as stringent or more stringent than the monitoring requirements specified in paragraphs (a) through (j) of this section, compliance with the monitoring requirements specified in 40 CFR part 63, subpart X also demonstrates compliance with the monitoring requirements specified in paragraphs (a) through (k) of this section.
Citations to §60.124(j)
-
(l) If an affected source is subject to the monitoring requirements specified in 40 CFR part 63, subpart X (National Emissions Standards for Hazardous Air Pollutants from Secondary Lead Smelting) and those requirements are as stringent or more stringent than the monitoring requirements specified in paragraphs (a) through (j) of this section, compliance with the monitoring requirements specified in 40 CFR part 63, subpart X also demonstrates compliance with the monitoring requirements specified in paragraphs (a) through (k) of this section.
-
(4) Electronic records of the pressure drop and water flow rate values for wet scrubbers used to control PM emissions from blast or reverberatory furnaces as required in § 60.124(j).
Citations to §60.124(k)
-
(l) If an affected source is subject to the monitoring requirements specified in 40 CFR part 63, subpart X (National Emissions Standards for Hazardous Air Pollutants from Secondary Lead Smelting) and those requirements are as stringent or more stringent than the monitoring requirements specified in paragraphs (a) through (j) of this section, compliance with the monitoring requirements specified in 40 CFR part 63, subpart X also demonstrates compliance with the monitoring requirements specified in paragraphs (a) through (k) of this section.
-
(10) Records of the rationale for the control device monitoring parameter value(s), established as specified in § 60.124(k), monitoring frequency, and averaging time. Include all data and calculations used to develop the value and a description of why the value, monitoring frequency, and averaging time demonstrate continuous compliance with the applicable emission standard.