§60.102. Standard for particulate matter. — Inbound Citations
40 C.F.R. § 60.102
Statutory Authority
Cited by 6 regulations in release Current.
Citations to 40 U.S.C. § 60.102 as a whole
-
(c) The average coke burn-off rate (Mg (tons) per hour) and hours of operation shall be recorded daily for any fluid catalytic cracking unit catalyst regenerator subject to § 60.102, § 60.103, or § 60.104(b)(2).
-
(1) Except as provided in paragraph (a)(5) of this section, meet each emission limitation in table 1 of this subpart that applies to you. If your catalytic cracking unit is subject to the NSPS for PM in § 60.102 of this chapter or is subject to § 60.102a(b)(1) of this chapter, you must meet the emission limitations for NSPS units. If your catalytic cracking unit is not subject to the NSPS for PM, you can choose from the six options in paragraphs (a)(1)(i) through (vi) of this section:(i) You can elect to comply with the NSPS for PM in § 60.102 of this chapter (Option 1a);(ii) You can elect to comply with the NSPS for PM coke burn-off emission limit in § 60.102a(b)(1) of this chapter (Option 1b);(iii) You can elect to comply with the NSPS for PM concentration limit in § 60.102a(b)(1) of this chapter (Option 1c);(iv) You can elect to comply with the PM per coke burn-off emission limit (Option 2);(v) You can elect to comply with the Nickel (Ni) lb/hr emission limit (Option 3); or
Citations to §60.102(a)
-
(b) The owner or operator shall determine compliance with the particulate matter (PM) standards in § 60.102(a) as follows:(1) The emission rate (E) of PM shall be computed for each run using the following equation:(2) Method 5B or 5F is to be used to determine particulate matter emissions and associated moisture content from affected facilities without wet FGD systems; only Method 5B is to be used after wet FGD systems. The sampling time for each run shall be at least 60 minutes and the sampling rate shall be at least 0.015 dscm/min (0.53 dscf/min), except that shorter sampling times may be approved by the Administrator when process variables or other factors preclude sampling for at least 60 minutes.(3) The coke burn-off rate (Rc) shall be computed for each run using the following equation:(i) Method 2 shall be used to determine the volumetric flow rate (Qr).(ii) The emission correction factor, integrated sampling and analysis procedure of Method 3B shall be used to determine CO2, CO, and O2 concentrations.(4) Method 9 and the procedures of § 60.11 shall be used to determine opacity.
Citations to §60.102(a)(1)
-
(i) Your fluid catalytic cracking unit regenerator vent is subject to the PM limit in 40 CFR 60.102(a)(1) and uses a wet scrubber for PM emissions control;
Citations to §60.102(a)(2)
-
(1) For fluid catalytic cracking unit catalyst regenerators subject to § 60.102(a)(2), an instrument for continuously monitoring and recording the opacity of emissions into the atmosphere. The instrument shall be spanned at 60, 70, or 80 percent opacity.
Citations to §60.102(b)
-
(c) If auxiliary liquid or solid fossil-fuels are burned in an incinerator-waste heat boiler, the owner or operator shall determine the emission rate of PM permitted in § 60.102(b) as follows:(1) The allowable emission rate (Es) of PM shall be computed for each run using the following equation:(2) Procedures subject to the approval of the Administrator shall be used to determine the heat input rate.(3) The procedure in paragraph (b)(3) of this section shall be used to determine the coke burn-off rate (Rc).