§59.652. Other procedures. — Inbound Citations
40 C.F.R. § 59.652
Statutory Authority
Cited by 6 regulations in release Current.
Citations to 40 C.F.R. § 59.652 as a whole
-
(t) On July 14, 2012, Pennsylvania repealed the provisions set forth in Sections 130.101 through 130.108 pertaining to Portable Fuel Containers. Pennsylvania's regulations in the Pennsylvania State Implementation Plan were removed because they are superseded by more stringent Federal requirements codified at 40 CFR 59.600 through 59.699, relating to control of evaporative emissions from new and in-use portable fuel containers.
-
(a) Hydrocarbon emissions from portable fuel containers may not exceed 0.3 grams per gallon per day when measured with the test procedures in §§ 59.650 through 59.653. This procedure measures diurnal venting emissions and permeation emissions.
-
(j) Report all test results, including those from invalid tests or from any other tests, whether or not they were conducted according to the test procedures of §§ 59.650 through 59.653. We may ask you to send other information to confirm that your tests were valid under the requirements of this subpart.
-
(a) Test your products using the procedures and equipment specified in §§ 59.650 through 59.653.
-
(ii) All your emission tests, including documentation on routine and standard tests, as specified in §§ 59.650 through 59.653, and the date and purpose of each test.
Citations to §59.652(c)
-
(1) . Perform a pressure test by sealing the container and cycling it between +13.8 and −3.4 kPa (+2.0 and −0.5 psig) for 10,000 cycles at a rate of 60 seconds per cycle. For this test, the spout may be removed, and the pressure applied through the opening where the spout attaches. The purpose of this test is to represent environmental wall stresses caused by pressure changes and other factors (such as vibration or thermal expansion). If your container cannot be tested using the pressure cycles specified by this paragraph (a)(1), you may ask to use special test procedures under § 59.652(c).