§257.5. Disposal standards for owners/operators of non-municipal non-hazardous waste disposal units that receive Very Small Quantity Generator (VSQG) waste. — Inbound Citations

40 C.F.R. § 257.5

Cited by 9 regulations in release Current.

Citations to 40 U.S.C. § 257.5 as a whole

Citations to §257.5(a)

  • (a) The requirements in this section apply to units identified in § 257.5(a), except as provided in paragraph (b) of this section.
  • (a) Detection monitoring is required at facilities identified in § 257.5(a) at all ground-water monitoring wells defined under §§ 257.22 (a)(1) and (a)(2). At a minimum, a detection monitoring program must include the monitoring for the constituents listed in appendix I of 40 CFR part 258.
    (1) The Director of an approved State may delete any of the appendix I (Appendix I of 40 CFR part 258) monitoring parameters for a unit if it can be shown that the removed constituents are not reasonably expected to be contained in or derived from the waste contained in the unit.
    (2) The Director of an approved State may establish an alternative list of indicator parameters for a unit, in lieu of some or all of the constituents in appendix I to 40 CFR part 258, if the alternative parameters provide a reliable indication of releases from the unit to the ground water. In determining alternative parameters, the Director shall consider the following factors:
    (i) The types, quantities, and concentrations of constituents in waste managed at the unit;
    (ii) The mobility, stability, and persistence of waste constituents or their reaction products in the unsaturated zone beneath the unit;
    (iii) The detectability of indicator parameters, waste constituents, and reaction products in the ground water; and
    (iv) The concentration or values and coefficients of variation of monitoring parameters or constituents in the groundwater background.

Citations to §257.5(b)

  • (a) A ground-water monitoring system must be installed that consists of a sufficient number of wells, installed at appropriate locations and depths, to yield ground-water samples from the uppermost aquifer (as defined in § 257.5(b)) that:
    (1) A determination of background quality may include sampling of wells that are not hydraulically upgradient of the waste management area where:
    (i) Hydrogeologic conditions do not allow the owner or operator to determine what wells are hydraulically upgradient; or
    (ii) Sampling at other wells will provide an indication of background ground-water quality that is as representative or more representative than that provided by the upgradient wells; and
    (2) Represent the quality of ground water passing the relevant point of compliance specified by the Director of an approved State or at the waste management unit boundary in an unapproved State. The downgradient monitoring system must be installed at the relevant point of compliance specified by the Director of an approved State or at the waste management unit boundary in an unapproved State that ensures detection of ground-water contamination in the uppermost aquifer. The relevant point of compliance specified by the Director of an approved State shall be no more than 150 meters from the waste management unit boundary and shall be located on land owned by the owner of the facility. In determining the relevant point of compliance the State Director shall consider at least the following factors: the hydrogeologic characteristics of the unit and surrounding land, the volume and physical and chemical characteristics of the leachate, the quantity, quality and direction of flow of ground water, the proximity and withdrawal rate of the ground-water users, the availability of alternative drinking water supplies, the existing quality of the ground water, including other sources of contamination and their cumulative impacts on the ground water, and whether the ground water is currently used or reasonably expected to be used for drinking water, public health, safety, and welfare effects, and practicable capability of the owner or operator. When physical obstacles preclude installation of ground-water monitoring wells at the relevant point of compliance at existing units, the down-gradient monitoring system may be installed at the closest practicable distance hydraulically down-gradient from the relevant point of compliance specified by the Director of an approved State that ensures detection of groundwater contamination in the uppermost aquifer.