§211.207. Computation of the noise reduction rating (NRR).

40 C.F.R. § 211.207

Calculate the NRR for hearing protective devices by substituting the average attenuation values and standard deviations for the pertinent protector category for the sample data used in steps #6 and #7 in Figure 2. The values of −.2, 0, 0, 0, −.2, −.8, −3.0 in Step 2 and −16.1, −8.6, −3.2, 0, + 1.2, + 1.0, −1.1 in Step 4 of Figure 2 represent the standard “C”- and “A”-weighting relative response corrections applied to any sound levels at the indicated octave band center frequencies. (NOTE: The manufacturer may label the protector at values lower than indicated by the test results and this computation procedure, e.g. lower NRR from lower attenuation values. (Ref. § 211.211(b).)
Notes, amendments, and revision history

Authority

Authority: Sec. 8, Pub. L. 92-574, 86 Stat. 1241 (42 U.S.C. 4907), and additional authority as specified.

Source

Source: 44 FR 56139, Sept. 28, 1979, unless otherwise noted.

Source

Source: 44 FR 56127, Sept. 28, 1979, unless otherwise noted.