§146.70. Information to be evaluated by the Director. — Inbound Citations
40 C.F.R. § 146.70
Statutory Authority
Cited by 5 regulations in release Current.
Citations to 40 U.S.C. § 146.70 as a whole
-
(1) Casing and cement used in the construction of each newly drilled well shall be designed for the life expectancy of the well, including the post-closure care period. The casing and cementing program shall be designed to prevent the movement of fluids into or between USDWs, and to prevent potential leaks of fluids from the well. In determining and specifying casing and cementing requirements, the Director shall consider the following information as required by § 146.70:(i) Depth to the injection zone;(ii) Injection pressure, external pressure, internal pressure and axial loading;(iii) Hole size;(iv) Size and grade of all casing strings (well thickness, diameter, nominal weight, length, joint specification and construction material);(v) Corrosiveness of injected fluid, formation fluids and temperature;(vi) Lithology of injection and confining zones;(vii) Type or grade of cement; and
Citations to §146.70(a)
-
(b) The owner or operator of a Class I hazardous waste well shall identify the location of all wells within the area of review that penetrate the injection zone or the confining zone and shall submit as required in § 146.70(a):(1) A tabulation of all wells within the area of review that penetrate the injection zone or the confining zone; and
-
(7) The calculated area of review based on data obtained during logging and testing of the well and the formation, and where necessary revisions to the information submitted under § 146.70(a) (2) and (3).
Citations to §146.70(a)(9)
-
(4) The results of the injection zone and confining zone testing program as required in § 146.70(a)(9);
Citations to §146.70(a)(15)
-
(8) The status of corrective action on wells identified in § 146.70(a)(15).