§1065.372. NDUV analyzer HC and H 2 O interference verification. — Inbound Citations
40 C.F.R. § 1065.372
Statutory Authority
Cited by 2 regulations in release Current.
Citations to 40 U.S.C. § 1065.372 as a whole
-
(b) We recommend that you use an NDUV analyzer that meets the specifications in Table 1 of § 1065.205. Note that your NDUV-based system must meet the verifications in § 1065.372 and it must also meet the linearity verification in § 1065.307.
-
(1) Perform SO2 and H2O interference verification for NDUV analyzers using the procedures of § 1065.372, replacing occurances of NOX with NH3. NDUV analyzers must have combined interference that is within (0.0 ±2.0) µmol/mol.