§183.425. Conductors: General.

33 C.F.R. § 183.425

(a)
Each conductor must be insulated, stranded copper.
(b)
Except for intermittent surges each conductor must not carry a current greater than that specified in Table 5 for the conductor's gauge and temperature rating.
(c)
For conductors in engine spaces, amperages must be corrected by the appropriate correction factor in note 1 of Table 5.
(d)
Each conductor in a multiconductor sheath must be at least a No. 18 AWG conductor.
(e)
Each conductor installed separately must be at least a No. 16 AWG conductor.
(f)
Each No. 18 AWG conductor in a multiconductor sheath may not extend out of the sheath more than 30 inches.
(g)
This section does not apply to communications systems; electronic navigation equipment; electronic circuits having a current flow of less than one ampere; conductors which are totally inside an equipment housing; resistance conductors that control circuit amperage; high voltage secondary conductors and terminations that are in ignition systems; pigtails of less than seven inches of exposed length and cranking motor conductors.
Notes, amendments, and revision history

Amendments

[CGD 73-217, 42 FR 5944, Jan. 31, 1977; 42 FR 24739, May 16, 1977, as amended by CGD 81-092, 48 FR 55736, Dec. 15, 1983]

Source

Source: CGD 73-217, 42 FR 5944, Jan. 31, 1977, unless otherwise noted.

Authority

Authority: 46 U.S.C. 4302; Pub. L. 103-206, 107 Stat. 2439; and Department of Homeland Security Delegation No. 0170.1, para. II, (92)(b). Subpart E is also authorized by Pub. L. 114-120, 130 Stat. 27