§159.55. Identification. — Inbound Citations
33 C.F.R. § 159.55
Statutory Authority
Cited by 2 regulations in release Current.
Citations to 33 U.S.C. § 159.55 as a whole
-
(b) During the test the device must be operated and maintained in accordance with the manufacturer's instructions. Any initial start-up time specified by the manufacturer must be allowed before test periods begin. For 1 hour of each 8-hour test period, the device must be tilted to the maximum angles specified by the manufacturer under §§ 159.55 and 159.57.
-
(a) The recognized facility must evaluate the information that is submitted by the manufacturer in accordance with § 159.14(b) (1), (2), and (3), evaluate the device for compliance with §§ 159.53 through 159.95, test the device in accordance with § 159.101 and submit to the Commanding Officer (MSC), Attn: Marine Safety Center, U.S. Coast Guard Stop 7430, 2703 Martin Luther King Jr. Avenue SE., Washington, DC 20593-7430 the following:(1) The information that is required under § 159.14(b);(2) A report on compliance evaluation;(3) A description of each test;(4) Test results; and(5) A statement, that is signed by the person in charge of testing, that the test results are accurate and complete.