US Codex
C.F.R.
Browse by date
Notes

§149.585. What are the requirements for sound signals?

33 C.F.R. § 149.585

(a)
Each pumping platform complex must have a sound signal, approved under subpart 67.10 of this chapter, that has a 2-mile (3-kilometer) range. A list of Coast Guard-approved sound signals is available from any District Commander.
(b)
Each sound signal must be:
(1)
Located at least 10 feet, but not more than 150 feet, above mean high water; and
(2)
Located where the structure of the platform, or equipment mounted on it, does not obstruct the sound of the signal in any direction.
Notes, amendments, and revision history

Authority

Authority: 33 U.S.C. 1504, 1509; DHS Delegation No. 00170.1, Revision No. 01.4.

Source

Source: USCG-1998-3884, 71 FR 57651, Sept. 29, 2006, unless otherwise noted.