US Codex
C.F.R.
Browse by date
Notes

§77.1434. Retirement criteria.

30 C.F.R. § 77.1434

Unless damage or deterioration is removed by cutoff, wire ropes shall be removed from service when any of the following conditions occurs:
(a)
The number of broken wires within a rope lay length, excluding filler wires, exceeds either—
(1)
Five percent of the total number of wires; or
(2)
Fifteen percent of the total number of wires within any strand;
(b)
On a regular lay rope, more than one broken wire in the valley between strands in one rope lay length;
(c)
A loss of more than one-third of the original diameter of the outer wires;
(d)
Rope deterioration from corrosion;
(e)
Distortion of the rope structure;
(f)
Heat damage from any source;
(g)
Diameter reduction due to wear that exceeds six percent of the baseline diameter measurement; or
(h)
Loss of more than ten percent of rope strength as determined by nondestructive testing.
Notes, amendments, and revision history

Authority

Authority: Sections 77.1430 through 77.1438 issued under sec. 101, Federal Mine Safety and Health Act of 1977, Pub. L. 91-173 as amended by Pub. L. 95-164, 91 Stat. 1291 (30 U.S.C. 811).

Source

Source: Sections 77.1430 through 77.1438 appear at 48 FR 53241, Nov. 25, 1983, unless otherwise noted.

Authority

Authority: 30 U.S.C. 811.

Source

Source: 36 FR 9364, May 22, 1971, unless otherwise noted.