§75.1908. Nonpermissible diesel-powered equipment; categories. — Inbound Citations

30 C.F.R. § 75.1908

Cited by 9 regulations in release Current.

Citations to §75.1908(a)

  • (c) Each piece of nonpermissible heavy-duty diesel-powered equipment (as defined by § 75.1908(a)), generator or compressor operated in an underground area of an underground coal mine must emit no more than 2.5 grams per hour of diesel particulate matter.
  • (c) Self-propelled nonpermissible heavy-duty diesel-powered equipment under § 75.1908(a), except rail-mounted equipment, shall be provided with a supplemental braking system that:
    (1) Engages automatically within 5 seconds of the shutdown of the engine;
    (2) Safely brings the equipment when fully loaded to a complete stop on the maximum grade on which it is operated;
    (3) Holds the equipment stationary, despite any contraction of brake parts, exhaustion of any nonmechanical source of energy, or leakage;
    (4) Releases only by a manual control that does not operate any other equipment function;
    (5) Has a means in the equipment operator's compartment to apply the brakes manually without shutting down the engine, and a means to release and reengage the brakes without the engine operating; and
    (6) Has a means to ensure that the supplemental braking system is released before the equipment can be trammed, and is designed to ensure the brake is fully released at all times while the equipment is trammed.
  • (g) Undiluted exhaust emissions of diesel engines in diesel-powered equipment approved under part 36 and heavy-duty nonpermissible diesel-powered equipment as defined in § 75.1908(a) in use in underground coal mines shall be tested and evaluated weekly by a person who is trained to perform this task. The mine operator shall develop and implement written standard operating procedures for such testing and evaluation that specify the following:
    (1) The method of achieving a repeatable loaded engine operating condition for each type of equipment;
    (2) Sampling and analytical methods (including calibration of instrumentation) that are capable of accurately detecting carbon monoxide in the expected concentrations;
    (3) The method of evaluation and interpretation of the results;
    (4) The concentration or changes in concentration of carbon monoxide that will indicate a change in engine performance. Carbon monoxide concentration shall not exceed 2500 parts per million; and

Citations to §75.1908(b)

  • (a) Each piece of nonpermissible light-duty diesel-powered equipment (as defined by § 75.1908(b) of this chapter), other than generators and compressors, introduced into an underground area of an underground coal mine after May 21, 2001 must emit no more than 5.0 grams per hour of diesel particulate matter.
  • (d) Self-propelled nonpermissible light-duty diesel-powered equipment under § 75.1908(b), except rail-mounted equipment, must be provided with a parking brake that holds the fully loaded equipment stationary on the maximum grade on which it is operated despite any contraction of the brake parts, exhaustion of any nonmechanical source of energy, or leakage.
  • (1) Self-propelled equipment meeting the requirements of § 75.1908(b);

Citations to §75.1908(d)

  • (c) As of November 25, 1999 nonpermissible diesel-powered equipment, except the special category of equipment under § 75.1908(d), shall meet the requirements of §§ 75.1909 and 75.1910 of this part.
  • (a) Nonpermissible diesel-powered equipment, except for the special category of equipment under § 75.1908(d), must be equipped with the following features:
    (1) An engine approved under subpart E of part 7 of this title equipped with an air filter sized in accordance with the engine manufacturer's recommendations, and an air filter service indicator set in accordance with the engine manufacturer's recommendations;
    (2) At least one portable multipurpose dry chemical type (ABC) fire extinguisher listed or approved by a nationally recognized independent testing laboratory with a 10A:60B:C or higher rating. The fire extinguisher must be located within easy reach of the equipment operator and protected from damage;
    (i) A fuel tank and fuel lines that do not leak;
    (ii) A fuel tank that is substantially constructed and protected against damage by collision;
    (iii) A vent opening that maintains atmospheric pressure in the fuel tank, and that is designed to prevent fuel from splashing out of the vent opening;
    (iv) A self-closing filler cap on the fuel tank;
    (v) The fuel tank, filler and vent must be located so that leaks or spillage during refueling will not contact hot surfaces;
    (vi) Fuel line piping must be either steel-wire reinforced; synthetic elastomer-covered hose suitable for use with diesel fuel that has been tested and has been determined to be fire-resistant by the manufacturer; or metal;
    (vii) Fuel line piping must be clamped;
    (viii) Primary fuel lines must be located so that fuel line leaks do not contact hot surfaces;
    (ix) The fuel lines must be separated from electrical wiring and protected from damage in ordinary use;
    (x) A manual shutoff valve must be installed in the fuel system as close as practicable to the tank; and
    (xi) A water separator and fuel filter(s) must be provided.
    (4) A sensor to monitor the temperature and provide a visual warning of an overheated cylinder head on air-cooled engines;
    (5) Guarding to protect fuel, hydraulic, and electric lines when such lines pass near rotating parts or in the event of shaft failure;
    (6) Hydraulic tanks, fillers, vents, and lines located to prevent spillage or leaks from contacting hot surfaces;
    (7) Reflectors or warning lights mounted on the equipment which can be readily seen in all directions;
    (8) A means to direct exhaust gas away from the equipment operator, persons on board the machine, and combustible machine components;
    (9) A means to prevent unintentional free and uncontrolled descent of personnel-elevating work platforms; and
    (10) A means to prevent the spray from ruptured hydraulic or lubricating oil lines from being ignited by contact with engine exhaust system component surfaces.
  • Electrical circuits and components associated with or connected to electrical systems on nonpermissible diesel-powered equipment utilizing storage batteries and integral charging systems, except for the special category of equipment under § 75.1908(d), must conform to the following requirements: