§7.68. Firing line terminals test.
30 C.F.R. § 7.68
Test procedures.
The contact resistance through each firing line terminal shall be determined.
A 10-pound pull shall be applied to a No. 18 gauge wire that has been connected to each firing line terminal according to the manufacturer's instructions.
Acceptable performance.
The contact resistance shall not be greater than 1 ohm.
The No. 18 gauge wire shall not become disconnected from either firing line terminal.