§18.53. High-voltage longwall mining systems. — Inbound Citations
30 C.F.R. § 18.53
Statutory Authority
Cited by 4 regulations in release Current.
Citations to §18.53(a)
Citations to §18.53(b)
Citations to §18.53(f)
-
(b) Disconnecting devices for motor-starter enclosures must be maintained in accordance with the approval requirements of paragraph (f) of § 18.53 of part 18 of this chapter. The compartment for the disconnect device must be provided with a caution label to warn miners against entering the compartment before deenergizing the incoming high-voltage circuits to the compartment.
Citations to §18.53(f)(2)(iv)
-
(e) Disconnecting devices, except those installed in explosion-proof enclosures, must be capable of interrupting the full-load current of the circuit or designed and installed to cause the current to be interrupted automatically prior to the opening of the contacts of the device. Disconnecting devices installed in explosion-proof enclosures must be maintained in accordance with the approval requirements of paragraph (f)(2)(iv) of § 18.53 of part 18 of this chapter.