§1917.24. Carbon monoxide.

29 C.F.R. § 1917.24

(a)
Exposure limits. The carbon monoxide content of the atmosphere in a room, building, vehicle, railcar, or any enclosed space shall be maintained at not more than 50 parts per million (ppm) (0.005%) as an eight hour average area level and employees shall be removed from the enclosed space if the carbon monoxide concentration exceeds a ceiling of 100 ppm (0.01%).
(b)
Testing. Tests to determine carbon monoxide concentration shall be made when necessary to ensure that employee exposure does not exceed the limits specified in paragraph (a) of this section.
(c)
Instrumentation. Tests for carbon monoxide concentration shall be made by designated persons using gas detector tube units certified by NIOSH under 30 CFR part 11 or other measuring instruments whose accuracy is as great or greater.
(d)
Records. A record of the date, time, location and results of carbon monoxide tests shall be available for at least thirty (30) days.
Notes, amendments, and revision history

Amendments

[48 FR 30909, July 5, 1983, as amended at 49 FR 28551, July 13, 1984; 61 FR 5509, Feb. 13, 1996; 62 FR 40197, July 25, 1997]

Authority

Authority: 33 U.S.C. 941; 29 U.S.C. 653, 655, 657; Secretary of Labor's Order No. 12-71 (36 FR 8754), 8-76 (41 FR 25059), 9-83 (48 FR 35736), 1-90 (55 FR 9033), 6-96 (62 FR 111), 3-2000 (65 FR 50017), 5-2002 (67 FR 65008), 5-2007 (72 FR 31160), 4-2010 (75 FR 55355), 1-2012 (77 FR 3912), 8-2020 (85 FR 58393), or 7-2025 (90 FR 27878), as applicable; and 29 CFR part 1911. Sections 1917.28 and 1917.31 also issued under 5 U.S.C. 553. Section 1917.29 also issued under 49 U.S.C. 1801-1819 and 5 U.S.C. 553.

Source

Source: 48 FR 30909, July 5, 1983, unless otherwise noted.