§30.23. Use of precision hydrometers and thermometers. — Inbound Citations
27 C.F.R. § 30.23
Statutory Authority
Cited by 5 regulations in release Current.
Citations to 27 U.S.C. § 30.23 as a whole
-
The provisions of § 30.23 respecting the care, handling, and use of precision instruments shall be followed with respect to the care, handling, and use of precision grade specific gravity hydrometers. Specific gravity hydrometers shall be read to the nearest subdivision. Because of temperature density relationships and the selection of the standardization temperature of 60 °/60 °F., the specific gravity readings will be greater at temperatures below 60 degrees Fahrenheit and less at temperatures above 60 degrees Fahrenheit. Hence, correction of the specific gravity readings will be made for temperature other than 60 degrees Fahrenheit. Such correction may be ascertained by dividing the specific gravity hydrometer reading by the applicable correction factor in Table 7.
-
(b) Except as otherwise authorized by the appropriate TTB officer, the proof of spirits containing not more than 600 milligrams of solids per 100 milliliters of spirits shall be determined by the use of a hydrometer and thermometer in accordance with the provisions of § 30.23 except that if such spirits contain solids in excess of 400 milligrams but not in excess of 600 milligrams per 100 milliliters at gauge proof, there shall be added to the proof so determined the obscuration determined as prescribed in § 30.32.
-
(c) Determine the apparent proof and temperature of the sample of spirits and then distill a carefully measured sample in a small laboratory still, and collect a quantity of the distillate, 1 or 2 milliliters less than the original sample. The distillate is adjusted to the original temperature and restored to the original volume by addition of distilled water. The proof of the restored distillate is then determined by use of a precision hydrometer and thermometer in accordance with the provisions of § 30.23 to the nearest 0.1 degree of proof. The difference between the proof so determined and the apparent proof of the undistilled sample is the obscuration; or
-
(a) Use of a precision hydrometer and thermometer, in accordance with the provisions of § 30.23, to determine the apparent proof of the spirits (if specific gravity at the temperature of the spirits is not more than 1.0) and reference to Table 4 for the wine gallons per pound, or
-
The proof of spirits shall be determined to the nearest tenth degree which shall be the proof used in determining the proof gallons and all fractional parts thereof to the nearest tenth proof gallon. The proof of spirits containing solids of 400 milligrams or less per 100 milliliters shall be determined by the use of a hydrometer and a thermometer in accordance with the provisions of § 30.23. However, notwithstanding the provisions of § 30.31, the proprietor may, at their option, add to the proof so determined the obscuration determined as prescribed in § 30.32.