§3285.504. Skirting.
24 C.F.R. § 3285.504
Skirting, if used, must be of weather-resistant materials or provided with protection against weather deterioration at least equivalent to that provided by a coating of zinc on steel of not less than 0.30 oz./ft. 2 of surface coated.
Skirting must not be attached in a manner that can cause water to be trapped between the siding and trim or forced up into the wall cavities trim to which it is attached.
All wood skirting within 6 inches of the ground must be pressure-treated in accordance with AWPA Standard U1 (incorporated by reference, see § 3285.4) for Use Category 4A, Ground Anchor Contact Applications, or be naturally resistant to decay and termite infestations.
Skirting must not be attached in a manner that impedes the contraction and expansion characteristics of the home's exterior covering.
Notes, amendments, and revision history
Authority
Authority: 42 U.S.C. 3535(d), 5403, 5404, and 5424.