§3285.307. Perimeter support piers.

24 C.F.R. § 3285.307

(a)
Piers required at mate-line supports, perimeter piers, and piers at exterior wall openings are permitted to be constructed of single open-cell or closed-cell concrete blocks, with nominal dimensions of 8 inches × 8 inches × 16 inches, to a maximum height of 54 inches, as shown in Figure A to this section, when the design capacity of the block is not exceeded.
(b)
Piers used for perimeter support must be installed with the long dimension parallel to the perimeter rail.