US Codex
C.F.R.
Browse by date
Notes

§1505.51. Hot surfaces.

16 C.F.R. § 1505.51

(a)
Test probe. Section 1505.6(g)(2) defines accessibility, for certain paragraphs, as the ability to reach a heated surface with a 1/4-inch-diameter rod 3 inches long. To test for accessibility using this test probe, it shall be inserted no more than 3 inches into any opening in the toy. Unless the probe contacts a surface within 3 inches of the plane of the toy's opening, that surface is not accessible.
(b)
Accessibility of Type C and C-marked surfaces. Under § 1505.6(g)(2) (iii) and (iv), touching by casual contact or without employing the aid of a common household tool shall be determined by use of the accessibility test probe described in §§ 1505.6(g)(2) and 1505.51(a).
Notes, amendments, and revision history

Amendments

[51 FR 34199, Sept. 26, 1986]

Authority

Authority: 15 U.S.C. 1261-1262, 2079.

Source

Source: 38 FR 27032, Sept. 27, 1973, unless otherwise noted.

Amendments

[51 FR 34199, Sept. 26, 1986]