§29.861. Fire protection of structure, controls, and other parts.
14 C.F.R. § 29.861
Each part of the structure, controls, and the rotor mechanism, and other parts essential to controlled landing and (for category A) flight that would be affected by powerplant fires must be isolated under § 29.1191, or must be—
For category A rotorcraft, fireproof; and
For Category B rotorcraft, fireproof or protected so that they can perform their essential functions for at least 5 minutes under any foreseeable powerplant fire conditions.
Notes, amendments, and revision history
Amendments
[Doc. No. 5084, 29 FR 16150, Dec. 3, 1964, as amended by Amdt. 27-26, 55 FR 8005, Mar. 6, 1990]
Authority
Authority: 49 U.S.C. 106(f), 106(g), 40113, 44701-44702, 44704.
Source
Source: Docket No. 5084, 29 FR 16150, Dec. 3, 1964, unless otherwise noted.
Amendments