§29.1359. Electrical system fire and smoke protection.

14 C.F.R. § 29.1359

(a)
Components of the electrical system must meet the applicable fire and smoke protection provisions of §§ 29.831 and 29.863.
(b)
Electrical cables, terminals, and equipment, in designated fire zones, and that are used in emergency procedures, must be at least fire resistant.
(c)
Insulation on electrical wire and cable installed in the rotorcraft must be self-extinguishing when tested in accordance with Appendix F, Part I(a)(3), of part 25 of this chapter.
Notes, amendments, and revision history

Amendments

[Doc. No. 5084, 29 FR 16150, Dec. 3, 1964, as amended by Amdt. 29-42, 63 FR 43285, Aug. 12, 1998]

Authority

Authority: 49 U.S.C. 106(f), 106(g), 40113, 44701-44702, 44704.

Source

Source: Docket No. 5084, 29 FR 16150, Dec. 3, 1964, unless otherwise noted.