§25.803. Emergency evacuation.

14 C.F.R. § 25.803

(a)
Each crew and passenger area must have emergency means to allow rapid evacuation in crash landings, with the landing gear extended as well as with the landing gear retracted, considering the possibility of the airplane being on fire.
(b)
[Reserved]
(c)
For airplanes having a seating capacity of more than 44 passengers, it must be shown that the maximum seating capacity, including the number of crewmembers required by the operating rules for which certification is requested, can be evacuated from the airplane to the ground under simulated emergency conditions within 90 seconds. Compliance with this requirement must be shown by actual demonstration using the test criteria outlined in appendix J of this part unless the Administrator finds that a combination of analysis and testing will provide data equivalent to that which would be obtained by actual demonstration.
(d)
-(e) [Reserved]
Notes, amendments, and revision history

Amendments

[Doc. No. 24344, 55 FR 29781, July 20, 1990]

Authority

Authority: 49 U.S.C. 106(f), 106(g), 40113, 44701, 44702 and 44704; Pub. L. 115-254, 132 Stat 3281 (49 U.S.C. 44903 note).

Source

Source: Docket No. 5066, 29 FR 18291, Dec. 24, 1964, unless otherwise noted.

Amendments

[Doc. No. 24344, 55 FR 29781, July 20, 1990]