§25.1715. Electrical bonding and protection against static electricity: EWIS.
14 C.F.R. § 25.1715
EWIS components used for electrical bonding and protection against static electricity must meet the requirements of § 25.899.
On airplanes having grounded electrical systems, electrical bonding provided by EWIS components must provide an electrical return path capable of carrying both normal and fault currents without creating a shock hazard or damage to the EWIS components, other airplane system components, or airplane structure.
Notes, amendments, and revision history
Source
Source: Docket No. FAA-2004-18379, 72 FR 63406, Nov. 8, 2007, unless otherwise noted.
Authority
Authority: 49 U.S.C. 106(f), 106(g), 40113, 44701, 44702 and 44704; Pub. L. 115-254, 132 Stat 3281 (49 U.S.C. 44903 note).