§429.40. Candelabra base incandescent lamps and intermediate base incandescent lamps.
10 C.F.R. § 429.40
Sampling plan for selection of units for testing.
The requirements of § 429.11 are applicable to candelabra base incandescent lamps; and
For each basic model of candelabra base incandescent lamp and intermediate base incandescent lamp, a minimum sample of 21 lamps shall be randomly selected and tested. Any represented value of lamp wattage of a basic model shall be based on the sample and shall be less than or equal to the lower of:
The mean of the sample, where—
The lower 97.5 percent confidence limit (LCL) of the true mean divided by 0.95, where:
Certification reports.
The requirements of § 429.12 are applicable to candelabra base and intermediate base incandescent lamps; and
Pursuant to § 429.12(b)(13), a certification report shall include the following public product-specific information:
Candelabra base incandescent lamp— The rated wattage in watts (W).
Intermediate base incandescent lamp— The rated wattage in watts (W).
Notes, amendments, and revision history
Amendments
[76 FR 12451, Mar. 7, 2011; 76 FR 24774, May 2, 2011]
Authority
Authority: 42 U.S.C. 6291-6317; 28 U.S.C. 2461 note.
Source
Source: 76 FR 12451, Mar. 7, 2011, unless otherwise noted.
Amendments
[76 FR 12451, Mar. 7, 2011; 76 FR 24774, May 2, 2011]