§429.17. Water heaters.
10 C.F.R. § 429.17
(1) The mean of the sample, where:
(2) The upper 95-percent confidence limit (UCL) of the true mean divided by 1.10, where:
And x is the sample mean; s is the sample standard deviation; n is the number of samples; and t0.95 is the t statistic for a 95-percent one-tailed confidence interval with n-1 degrees of freedom (from Appendix A).
(1) The mean of the sample, where:
(2) The lower 95-percent confidence limit (LCL) of the true mean divided by 0.90, where:
And x is the sample mean; s is the sample standard deviation; n is the number of samples; and t0.95 is the t statistic for a 95-percent one-tailed confidence interval with n-1 degrees of freedom (from Appendix A).
(1) To demonstrate compliance with the energy conservation standards in § 430.32(d)(1) of this chapter, any represented value of uniform energy factor shall be determined based on testing in accordance with section 5.1.1 of appendix E to subpart B of 10 CFR part 430.
(2) To demonstrate compliance with the energy conservation standards in § 430.32(d)(2) of this chapter, any represented value of uniform energy factor shall be determined based on high temperature testing in accordance with section 5.1.2 of appendix E to subpart B of 10 CFR part 430.
Notes, amendments, and revision history
Amendments
[81 FR 96235, Dec. 29, 2016, as amended at 87 FR 43977, July 22, 2022; 89 FR 37941 May 6, 2024]
Authority
Authority: 42 U.S.C. 6291-6317; 28 U.S.C. 2461 note.
Source
Source: 76 FR 12451, Mar. 7, 2011, unless otherwise noted.
Amendments
[81 FR 96235, Dec. 29, 2016, as amended at 87 FR 43977, July 22, 2022; 89 FR 37941 May 6, 2024]