§429.134. Product-specific enforcement provisions.
10 C.F.R. § 429.134
(1) If DOE used the same test cloth lot that was used by the manufacturer for testing and certifying the basic model, then the measured RMC value will be considered the tested unit's final RMC value.
(2) If DOE used a different test cloth lot than was used by the manufacturer for testing and certifying the basic model, then:
(i) If the measured RMC value of a tested unit is higher than the certified RMC value of the basic model by more than three RMC percentage points, then a value three RMC percentage points less than the measured RMC value will be considered the tested unit's final RMC value.
(ii) If the measured RMC value of a tested unit is higher than the certified RMC value of the basic model, but by no more than three RMC percentage points, then the certified RMC value of the basic model will be considered the tested unit's final RMC value.
(1) If DOE used the same test cloth lot that was used by the manufacturer for testing and certifying the basic model, then the measured RMC value will be considered the tested unit's final RMC value.
(2) If DOE used a different test cloth lot than was used by the manufacturer for testing and certifying the basic model, then the certified RMC value of the basic model would be considered the tested unit's final RMC value.
(1) If the average of the three RMC measurements is equal to or lower than the certified RMC value of the basic model, then the average RMC value will be considered the tested unit's final RMC value.
(2) If the average of the three RMC measurements is higher than the certified RMC value of the basic model but the difference between the measured and certified RMC values would not affect the unit's compliance with the applicable standards, then the average RMC value will be considered the tested unit's final RMC value.
(3) If the average of the three RMC measurements is higher than the certified RMC value of the basic model and the difference between the measured and certified RMC values would affect the unit's compliance with the applicable standards, then DOE will apply paragraph (c)(1)(ii)(F) of this section.
(1) If DOE used the same test cloth lot that was used by the manufacturer for testing and certifying the basic model, then the average RMC pursuant to paragraph (c)(1)(ii)(E) of this section will be considered the tested unit's final RMC value.
(2) If DOE used a different test cloth lot than was used by the manufacturer for testing and certifying the basic model, then:
(i) If the average RMC value pursuant to paragraph (c)(1)(ii)(D) of this section is higher than the certified valued of the basic model by more than three RMC percentage points, then a value three RMC percentage points less than the average RMC value will be considered the tested unit's final RMC value.
(ii) If the average RMC value pursuant to paragraph (c)(1)(ii)(D) of this section is higher than the certified RMC value of the basic model, but by no more than three RMC percentage points, then the certified RMC value of the basic model will be considered the tested unit's final RMC value.
(2) If the means for adjusting water temperature uses outdoor temperature reset, the maximum outdoor temperature setting (if equipped) should be set to a temperature high enough that the boiler operates continuously during the duration of this test (i.e., if the conditions in paragraph (h)(1)(ii)(A) of this section equal room ambient temperature, then the maximum outdoor temperature should be set at a temperature greater than the ambient air temperature during the test).
(2) The minimum supply water temperature of the default temperature reset curve is usually provided in the I&O manual. If there is no recommended minimum supply water temperature, set the minimum supply water temperature equal to 20 °F less than the high supply water temperature specified in paragraph (h)(1)(iii)(A) of this section.
(2) Record the boiler supply water temperature while the temperature is stabilized.
(2) Record the boiler supply water temperature while the temperature is stabilized.
(3) Terminate the call for heat.
(1) If the representative value of true priming time is found to be valid, the value of true priming time certified by the manufacturer will be used to determine the appropriate equipment class and standard level for that basic model.
(2) If the representative value of true priming time is found to be invalid, the mean of the values of true priming time determined from the tested unit(s) will be used to determine the appropriate equipment class and standard level for that basic model.
(1) If the measurement(s) of true priming time are greater than 95 percent of the value of true priming time referenced in the definition of non-self-priming pool filter pump at § 431.462 with a vertical lift of 5.0 feet, the DPPP model will be considered a non-self-priming pool filter pump for the purposes of determining the appropriate equipment class and standard level for that basic model.
(2) If the conditions specified in paragraph (i)(2)(ii)(B)(1) of this section are not satisfied, then the DPPP model will be considered a self-priming pool filter pump for the purposes of determining the appropriate equipment class and standard level for that basic model.
(2) Activate power to the pump with the flow rate set to zero (i.e., the pump is energized but not circulating water). Set the ambient temperature to 42.0 ± 0.5 °F and allow the temperature to stabilize, where stability is determined in accordance with section 40.6.3.2.2 of HI 40.6-2014-B. After 5 minutes, decrease the temperature measured by the freeze protection temperature sensor by 1.0 ± 0.5 °F and allow the temperature to stabilize. After each reduction in ambient temperature and subsequent stabilization, record the DPPP rotating speed, if any, and freeze protection ambient temperature reading, where the “freeze protection ambient temperature reading” is representative of the temperature measured by the freeze protection ambient temperature sensor, which may be recorded by a variety of means depending on how the temperature is being simulated and controlled. If no flow is initiated, record zero rpm or no flow. Continue decreasing the temperature measured by the freeze protection temperature sensor by 1.0 ± 0.5 °F after 5.0 minutes of stable operation at the previous temperature reading until the pump freeze protection initiates water circulation or until the ambient temperature of 38.0 ± 0.5 °F has been evaluated (i.e., the end of the 5.0 minute interval of 38.0 °F), whichever occurs first.
(3) If and when the DPPP freeze protection controls initiate water circulation, increase the ambient temperature reading registered by the freeze protection temperature sensor to a temperature of 42.0 ± 0.5 °F and maintain that temperature for 60.0 minutes. Do not modify or interfere with the operation of the DPPP freeze protection operating cycle. After 60.0 minutes, record the freeze protection ambient temperature and rotating speed, if any, of the dedicated-purpose pool pump under test.
(i) Determination of transparent area. Determine the total surface area that is transparent as the sum of all surface areas on the front side of a beverage vending machine that meet the definition of transparent at 10 CFR 431.292. When determining whether or not a particular wall segment is transparent, transparency should be determined for the aggregate performance of all the materials between the refrigerated volume and the ambient environment; the composite performance of all those materials in a particular wall segment must meet the definition of transparent for that area be treated as transparent.
(ii) Determination of non-transparent area. Determine the total surface area that is not transparent as the sum of all surface areas on the front side of a beverage vending machine that are not considered part of the transparent area, as determined in accordance with paragraph (j)(2)(i) of this section.
(1) If the specified tolerances are met under system operation for 60 minutes, the average capacity and average power measured over this 60-minute test interval shall be recorded.
(2) If the four-hour time limit is reached by the system without maintaining the tolerances for a 60-minute period, but two successive test period sub-intervals are identified, each a minimum of 30 minutes, and comprised of a whole number of compressor cycles (either compressor on-off cycles or speed/capacity cycles) or in which minimal fluctuations of the compressor speed/capacity level are observed, where both the time averaged integrated capacity and time averaged integrated power of the two successive test period sub-intervals are observed to be within two percent of each other, a single capacity average and a single power average shall be recorded, both averaged over compressor-on periods of the two successive test period sub-intervals. These average capacity and power values shall be considered the capacity and power values recorded for the test interval.
(3) If the four-hour time limit is reached by the system without complying with either paragraph (k)(4)(iii)(A)(1) or (2) of this section, the time averaged integrated capacity and time averaged integrated power shall be recorded for only the compressor-on periods over the final 120 minutes of the test interval.
(1) The compressor and indoor blower speed shall be monitored during the CVP conducted in paragraph (k)(4)(i)(A) or (B) of this section. The average compressor and indoor blower speeds and indoor air volume rate shall be evaluated for the same time period(s) used as described in paragraph (k)(4)(iii)(A) of this section to determine average capacity and power for the CVP test. The compressor speed for the certification test shall be set at this average value observed during the corresponding CVP test interval. The indoor blower speed shall be set as described in section 6.1.5 of AHRI 210/240-2024 (if testing in accordance with appendix M1 to subpart B of 10 CFR part 430; (incorporated by reference, see § 429.4)) or of AHRI 1600-2024 (if testing in accordance with appendix M2 to subpart B of 10 CFR part 430; (incorporated by reference, see § 429.4)), except the “specified airflow” shall be set as the average value observed during the corresponding CVP test interval. The same adjusted compressor speed shall be used for the other certification tests that require the same speed, as applicable, as detailed in table 1 to this paragraph (k)(4)(v)(A). Specifically, for each of the CVP tests listed in the first column for which either the capacity tolerances of paragraph (k)(4)(iii)(B) or (C) of this section are not met or the efficiency tolerances of paragraph (k)(4)(iii)(D) of this section are not met, the certification tests to be conducted again using the compressor speed determined in the corresponding CVP test are listed in the last three columns of the table, depending on which of the three kinds of system the model is designated.
(2) If required, the adjusted q H3,Full and PH3,Full shall be used to calculate q k=2hcalc(47) and Pk=2hcalc(47), respectively, to represent performance at 47 °F as described in section 11.2.2.4 of AHRI 210/240-2024 (if testing in accordance with appendix M1 to subpart B of 10 CFR part 430; (incorporated by reference, see § 429.4)) or of AHRI 1600-2024 (if testing in accordance with appendix M2 to subpart B of 10 CFR part 430; (incorporated by reference, see § 429.4)) and for use in calculating performance at 35 °F. If required, the adjusted H1Low and H3Low tests shall be used to calculate q thi,H2,Low and PH2,Low, respectively, as described in section 6.1.3.4 of AHRI 210/240-2024 (if testing in accordance with appendix M1 to subpart B of 10 CFR part 430; (incorporated by reference, see § 429.4)) or of AHRI 1600-2024 (if testing in accordance with appendix M2 to subpart B of 10 CFR part 430; (incorporated by reference, see § 429.4)). No adjustments are required for intermediate or nominal compressor speed tests or, if cyclic tests are conducted, for the degradation coefficient(s).
(1) The average capacities and power(s) measured during the CVP time period(s) described in paragraph (k)(4)(iii)(A) of this section shall be used (with no adjustment for tests having a CVP interval). For the certification tests requiring adjustment with no CVP interval (any required certification test in column 2, 3, or 4 of table 1 to paragraph (k)(4)(v)(A) of this section other than AFull, FLow, H1Low, H3Full and H4Full for which the column 1 CVP interval did not meet capacity or EER2/COP2/EER/COP tolerances), the capacity and power shall be adjusted. The capacity shall be adjusted by applying the ratio of the capacity measured during the CVP test interval divided by the capacity measured during the certification test (for the corresponding CVP interval). The power shall be adjusted by applying the ratio of the power measured during the CVP test interval divided by the power measured during the certification test (for the corresponding CVP interval), as follows:
Cooling full capacity:
Cooling full power:
Cooling minimum capacity:
Cooling minimum power:
Heating minimum capacity:
Heating minimum power:
(2) If required, the measured QH3,Full and EH3,Full from the CVP shall be used to calculate q k=2hcalc(47) and Pk=2hcalc(47), respectively, to represent performance at 47 °F as described in section 11.2.2.4 of AHRI 210/240-2024 (if testing in accordance with appendix M1 to subpart B of 10 CFR part 430; (incorporated by reference, see § 429.4)) or of AHRI 1600-2024 (if testing in accordance with appendix M2; (incorporated by reference, see § 429.4)), and for use in calculating performance at 35 °F. If required, the measured H1Low from the CVP and the adjusted H3Low tests shall be used to calculate q thi,H2,Low and PH2,Low, respectively, as described in section 6.1.3.4 of AHRI 210/240-2024 (if testing in accordance with appendix M1 to subpart B of 10 CFR part 430; (incorporated by reference, see § 429.4)) or of AHRI 1600-2024 (if testing in accordance with appendix M2 to subpart B of 10 CFR part 430; (incorporated by reference, see § 429.4)). No adjustments are required for intermediate or nominal compressor speed tests or, if cyclic tests are conducted, the degradation coefficient(s).
(1) Select the CVP measurement period—this period must have duration determined per paragraph (v)(3)(ii)(A) of this section and must be the period where the RSS points total has a lower average value over the measurement period than over any other time period in the CVP of the same duration. If multiple periods exist with the same RSS points total, select the measurement period closest to but before the time that the first indoor unit switches to thermally inactive (denoted as “toff” in AHRI 1230-2021).
(2) Determine alternate critical parameters—calculate the average position for each critical parameter during the measurement period selected in paragraph (v)(3)(iii)(B)(1) of this section. When initially setting critical parameters per section 5.1 of appendix D1 to subpart F of 10 CFR part 431, instead of using the certified critical parameter values, use the alternate critical parameter values as control inputs. The same initial alternate critical parameter values must be used for all systems in the assessment/enforcement sample (though critical parameter adjustments as needed to achieve target capacity or sensible heat ratio (SHR) limits are made independently for each tested system, per paragraph (v)(3)(iii)(B)(3) of this section.
(3) For each system, determine whether critical parameter adjustments are needed to achieve the target capacity or SHR limit for an IEER cooling test. Perform critical parameter adjustments independently on each system as described in section 5.2 of appendix D1 to subpart F of 10 CFR part 431, with the following exceptions:
(i) Replace all references to “certified critical parameter values” with “alternate critical parameter values” as determined in paragraph (v)(3)(iii)(B) of this section.
(ii) Determine CPMax from a CVP conducted at full-load cooling conditions as the maximum value observed during the R2 period as described in Section C.4.4.2.3 of AHRI 1230-2021. If multiple components corresponding to a single parameter are present, determine CPMax at the point during the R2 period at which the average value across all components corresponding to that critical parameter is maximized.
The outdoor ventilation airflow rate shall be determined at 0 in. H2O external static pressure with a tolerance of −0.00/+0.05 in. H2O.
Notes, amendments, and revision history
Amendments
[79 FR 22348, Apr. 21, 2014, as amended at 79 FR 40566, July 11, 2014; 80 FR 37148, June 30, 2015; 80 FR 45824, July 31, 2015; 80 FR 46760, Aug. 5, 2015; 80 FR 79669, Dec. 23, 2015; 81 FR 2646, Jan. 15, 2016; 81 FR 15426, Mar. 23, 2016; 81 FR 24009, Apr. 25, 2016; 81 FR 37055, June 8, 2016; 81 FR 38395, June 13, 2016; 81 FR 46791, July 18, 2016; 81 FR 79320, Nov. 10, 2016; 81 FR 96236, Dec. 29, 2016; 81 FR 89304, Dec. 9, 2016; 81 FR 89822, Dec. 12, 2016; 81 FR 95800, Dec. 28, 2016; 82 FR 1100, Jan. 4, 2017; 82 FR 36919, Aug. 7, 2017; 85 FR 1446, Jan. 10, 2020; 86 FR 56820, Oct. 12, 2021; 87 FR 33379, June 1, 2022; 87 FR 45197, July 27, 2022; 87 FR 50423, Aug. 16, 2022; 87 FR 55122, Sept. 8, 2022; 87 FR 57298, Sept. 19, 2022; 87 FR 63895, Oct. 20, 2022; 87 FR 65667, 65899, Nov. 1, 2022; 87 FR 75167, Dec. 7, 2022; 87 FR 77324, Dec. 16, 2022; 88 FR 3276, Jan. 18, 2023; 88 FR 15537, Mar. 13, 2023; 88 FR 17975, Mar. 24, 2023; 88 FR 21838, Apr. 11, 2023; 88 FR 28837, May 4, 2023; 88 FR 40472, June 21, 2023; 88 FR 34362, May 26, 2023; 88 FR 34702, May 30, 2023; 88 FR 48357, July 27, 2023; 88 FR 66222, Sept. 26, 2023; 88 FR 67041, Sept. 28, 2023; 88 FR 84228, Dec. 4, 2023; 89 FR 37942, May 6, 2024; 89 FR 44035, May 20, 2024; 89 FR 82070, Oct. 9, 2024; 90 FR 6790, Jan. 21, 2025; 90 FR 1278, Jan. 7, 2025; 90 FR 43371, 43384, Sept. 9, 2025]
Authority
Authority: 42 U.S.C. 6291-6317; 28 U.S.C. 2461 note.
Source
Source: 76 FR 12451, Mar. 7, 2011, unless otherwise noted.
Amendments
[79 FR 22348, Apr. 21, 2014, as amended at 79 FR 40566, July 11, 2014; 80 FR 37148, June 30, 2015; 80 FR 45824, July 31, 2015; 80 FR 46760, Aug. 5, 2015; 80 FR 79669, Dec. 23, 2015; 81 FR 2646, Jan. 15, 2016; 81 FR 15426, Mar. 23, 2016; 81 FR 24009, Apr. 25, 2016; 81 FR 37055, June 8, 2016; 81 FR 38395, June 13, 2016; 81 FR 46791, July 18, 2016; 81 FR 79320, Nov. 10, 2016; 81 FR 96236, Dec. 29, 2016; 81 FR 89304, Dec. 9, 2016; 81 FR 89822, Dec. 12, 2016; 81 FR 95800, Dec. 28, 2016; 82 FR 1100, Jan. 4, 2017; 82 FR 36919, Aug. 7, 2017; 85 FR 1446, Jan. 10, 2020; 86 FR 56820, Oct. 12, 2021; 87 FR 33379, June 1, 2022; 87 FR 45197, July 27, 2022; 87 FR 50423, Aug. 16, 2022; 87 FR 55122, Sept. 8, 2022; 87 FR 57298, Sept. 19, 2022; 87 FR 63895, Oct. 20, 2022; 87 FR 65667, 65899, Nov. 1, 2022; 87 FR 75167, Dec. 7, 2022; 87 FR 77324, Dec. 16, 2022; 88 FR 3276, Jan. 18, 2023; 88 FR 15537, Mar. 13, 2023; 88 FR 17975, Mar. 24, 2023; 88 FR 21838, Apr. 11, 2023; 88 FR 28837, May 4, 2023; 88 FR 40472, June 21, 2023; 88 FR 34362, May 26, 2023; 88 FR 34702, May 30, 2023; 88 FR 48357, July 27, 2023; 88 FR 66222, Sept. 26, 2023; 88 FR 67041, Sept. 28, 2023; 88 FR 84228, Dec. 4, 2023; 89 FR 37942, May 6, 2024; 89 FR 44035, May 20, 2024; 89 FR 82070, Oct. 9, 2024; 90 FR 6790, Jan. 21, 2025; 90 FR 1278, Jan. 7, 2025; 90 FR 43371, 43384, Sept. 9, 2025]