Ceiling Fan Improvement Act of 2020
AN ACT
To amend the Energy Policy and Conservation Act to make technical corrections to the energy conservation standard for ceiling fans, and for other purposes.
Sec. 2 Modifications to the ceiling fan energy conservation standard
“(C)
“(i) Large-diameter ceiling fans manufactured on or after January 21, 2020, shall—
“(I) not be required to meet minimum ceiling fan efficiency in terms of ratio of the total airflow to the total power consumption as described in the final rule titled “Energy Conservation Program: Energy Conservation Standards for Ceiling Fans” (82 Fed. Reg. 6826 (January 19, 2017)); and
“(II) have a CFEI greater than or equal to—
“(aa) 1.00 at high speed; and
“(bb) 1.31 at 40 percent speed or the nearest speed that is not less than 40 percent speed.
“(ii) For purposes of this subparagraph, the term CFEI means the Fan Energy Index for large-diameter ceiling fans, calculated in accordance with ANSI/AMCA Standard 208–18 titled “Calculation of the Fan Energy Index”, with the following modifications:
“(I) Using an Airflow Constant (Q0) of 26,500 cubic feet per minute.
“(II) Using a Pressure Constant (P0) of 0.0027 inches water gauge.
“(III) Using a Fan Efficiency Constant (η0) of 42 percent.”