# §236.106. Relays.


Each relay, the functioning of which affects the safety of train operations, shall be tested at least once every four years except:

- (a) Alternating current centrifugal type relay shall be tested at least once every 12 months;
- (b) Alternating current vane type relay and direct current polar type relay shall be tested at least once every 2 years; and
- (c) Relay with soft iron magnetic structure shall be tested at least once every 2 years.