kind: "section"
citation: "49 C.F.R. § 195.565"
title: "49"
number: "195.565"
heading: "How do I install cathodic protection on breakout tanks?"
url: "https://uscodex.org/cfr/49/195.565"
---

# §195.565. How do I install cathodic protection on breakout tanks?


After October 2, 2000, when you install cathodic protection under [§ 195.563(a)](/cfr/49/195.563.md?p=a) to protect the bottom of an aboveground breakout tank of more than 500 barrels 79.49m3 capacity built to API Spec 12F (incorporated by reference, see [§ 195.3](/cfr/49/195.3.md)), API Std 620 (incorporated by reference, see [§ 195.3](/cfr/49/195.3.md)), API Std 650 (incorporated by reference, see [§ 195.3](/cfr/49/195.3.md)), or API Std 650's predecessor, Standard 12C, you must install the system in accordance with ANSI/API RP 651 (incorporated by reference, see [§ 195.3](/cfr/49/195.3.md)). However, you don't need to comply with API RP 651 when installing any tank for which you note in the corrosion control procedures established under [§ 195.402(c)(3)](/cfr/49/195.402.md?p=c-3) why complying with all or certain provisions of API RP 651 is not necessary for the safety of the tank.


## Notes

### Amendments

[Amdt. 195-99, 80 FR 188, Jan. 5, 2015, as amended by Amdt. 195-107, 89 FR 33284, Apr. 29, 2024]

### Source

Source: Amdt. 195-73, 66 FR 67004, Dec. 27, 2001, unless otherwise noted.

### Authority

Authority: 30 U.S.C. 185(w)(3), 49 U.S.C. 5103, 60101 et seq., and 49 CFR 1.97.

### Source

Source: Amdt. 195-22, 46 FR 38360, July 27, 1981, unless otherwise noted.

### Amendments

[Amdt. 195-99, 80 FR 188, Jan. 5, 2015, as amended by Amdt. 195-107, 89 FR 33284, Apr. 29, 2024]