kind: "section"
citation: "49 C.F.R. § 195.559"
title: "49"
number: "195.559"
heading: "What coating material may I use for external corrosion control?"
url: "https://uscodex.org/cfr/49/195.559"
---

# §195.559. What coating material may I use for external corrosion control?


Coating material for external corrosion control under [§ 195.557](/cfr/49/195.557.md) must—

- (a) Be designed to mitigate corrosion of the buried or submerged pipeline;
- (b) Have sufficient adhesion to the metal surface to prevent under film migration of moisture;
- (c) Be sufficiently ductile to resist cracking;
- (d) Have enough strength to resist damage due to handling and soil stress;
- (e) Support any supplemental cathodic protection; and
- (f) If the coating is an insulating type, have low moisture absorption and provide high electrical resistance.

## Notes

### Source

Source: Amdt. 195-73, 66 FR 67004, Dec. 27, 2001, unless otherwise noted.

### Authority

Authority: 30 U.S.C. 185(w)(3), 49 U.S.C. 5103, 60101 et seq., and 49 CFR 1.97.

### Source

Source: Amdt. 195-22, 46 FR 38360, July 27, 1981, unless otherwise noted.