# §95.3205. Unwanted emissions limits.

- (a) C-V2X OBUs must comply with the following out-of-band emissions limits. Conducted emissions limits measured at the antenna input shall not exceed:
  - (1) −16 dBm/100 kHz within ±1 megahertz of the band edges;
  - (2) −13 dBm/MHz within ±1 megahertz to ±5 megahertz of the band edges;
  - (3) −16 dBm/MHz within ±5 megahertz to ±30 megahertz of the band edges; and
  - (4) −28 dBm/MHz beyond 30 megahertz from the band edges.

## Notes

### Amendments

[89 FR 100855, Dec. 13, 2024]

### Source

Source: 89 FR 100855, Dec. 13, 2024, unless otherwise noted.

### Authority

Authority: 47 U.S.C. 154, 303, 307.

### Source

Source: 82 FR 41104, Aug. 29, 2017, unless otherwise noted.

### Amendments

[89 FR 100855, Dec. 13, 2024]