# §98.25-75. Ventilation.

- (a) All enclosed spaces containing cargo tanks fitted with bottom outlet connections shall be provided with mechanical ventilation of sufficient capacity to assure a change of air every 3 minutes. Where cargo tanks are fitted with top outlet connections, the enclosed spaces containing such tanks shall be fitted with efficient natural or mechanical ventilation.
- (b) Enclosed compartments in which machinery such as cargo pumps or vapor compressors are located shall be adequately ventilated.