# §95.01-5. Equipment installed but not required.

- (a) Where fire extinguishing systems or equipment are not required, but are installed, the system or equipment and its installation must meet the requirements of this part.
- (b) Use of non-approved fire detection systems may be acceptable as excess equipment provided that—
  - (1) Components are listed and labeled by an independent, nationally recognized testing laboratory as set forth in [29 CFR 1910.7](/cfr/29/1910.7.md), and are designed, installed, tested, and maintained in accordance with an appropriate industry standard and the manufacturer's specific guidance;
  - (2) Installation conforms to the requirements of [46 CFR chapter I](/cfr/46/chI.md), subchapter J (Electrical Engineering), especially the hazardous location electrical installation regulations in [46 CFR 111.105](/cfr/46/111.105.md); and
  - (3) **Coast Guard plan review is completed for wiring plans.**