# §64.95. Piping.

- (a) Piping, valves, flanges, and fittings used in the pumping system must be designed in accordance with [part 56](/cfr/46/part56.md) of this subchapter.
- (b) **A cargo loading and discharge header or manifold must—**
  - (1) Have stop valves to prevent cargo leakage; and
  - (2) **Be visible to the operator at the cargo pump controls.**
- (c) Each pipe and valve in the pumping system that has an open end must have a plug or cap to prevent leakage.
- (d) Each hose connection must be threaded or flanged except for a quick connect coupling that may be specifically accepted by the U.S. Coast Guard in accordance with the procedures in [§ 50.25-10](/cfr/46/50.25-10.md) of this subchapter.
- (e) A non-return valve must be in the pump discharge if a backflow condition may occur during pumping.
- (f) Any non-metallic flexible hose that is used in the piping system must comply with [§ 56.60-25(c)](/cfr/46/56.60-25.md?p=c) of this subchapter.

## Notes