# §64.63. Minimum emergency venting capacity.

- (a) The total emergency venting capacity (Q) of the relief devices of an uninsulated MPT must be in accordance with table 1 to § 64.63 or the following formula based upon the pressure relief device operating at a pressure not to exceed the test pressure:
- (b) The total emergency venting capacity (Q) of an insulated portable tank may have a reduction if—
  - (1) It is shown to the Coast Guard that the insulation reduces the heat transmission to the tank;
  - (2) The present reduction of the emergency venting capacity (Q) is limited to the percent reduction of the heat transmission to the tank or 50 percent, whichever is less; and
  - (3) **The insulation is sheathed.**